Electric shock from a light switch
A shock from a light switch means current is reaching the switch face. Lighting Electrical in Peterborough isolates that lighting circuit and tests the switch and the earth.
Calls answered 24/7
- 10 years trading
Why does a light switch give you a shock?
A light switch gives you a shock when live voltage reaches the face or the screws. A missing earth, a loose live joint, water in the box, damaged cable, or a fault on the supply earth will do that.
- A metal plate with no earthA metal switch needs an earth wire so fault current has a path away from your hand. If that wire is missing or loose, the plate can sit at a live voltage. Touching the plate or the screws then shocks you. A plastic plate can still shock you through the screws.
- A live joint loose in the boxThe live conductor can sit in the earth terminal, or a loose live can touch the metal box. The lamp may still light. The plate becomes live because the earth is then carrying the supply.
- Water across the switch terminalsSteam, a leak, or rain in an outside switch lets current track over the face. Wet skin makes the shock stronger. The lighting breaker or the RCD may open, or the leak can be too small to trip and still shock you.
- A broken combined earth and neutralSome supplies join earth and neutral in one conductor back to the network. If that conductor breaks, metalwork tied to earth can become live. A shock from the switch and from a tap is a warning of that fault. Those circuits stay off until the supply earth is sound.
- Damaged insulation on the lighting cableHeat or a nail can crack the insulation so the live conductor touches the switch box. The leak may be small. You feel it as a tingle on the screws, and it worsens as the damage grows.
What can I check safely after a shock from a light switch?
You can switch off the lighting breaker and note where you felt the shock. Leave every switch screw in place and do not press the switch again.
- Leave that switch aloneDo not press the switch again to see if the shock returns. Use a light on another circuit if you need to see. Keep children away from the plate until the lighting breaker is off.
- The lighting breakerAt the fuse board, use a dry hand on the breaker handle only. Switch off the breaker that feeds those lights. Leave the cover screws in place. If the board is hot or smells of burning, step away and Book Now.
- Where else you felt itNote whether one switch shocked you, or several switches, a tap, or a radiator as well. One switch points to that plate or its cable. Several points point to the earth or the supply.
- Marks you can see without touchingLook for brown marks, cracks, or a plate sitting proud, and listen for a buzz. A burning smell counts as well. Do not wipe a wet switch while it is still live. Switch the breaker off first.
When should I book after a shock from a light switch?
Book Now after any shock or tingle from a light switch. One shock is enough, even when the light still works.
- Any shock or tingleA single shock means the face or the screws were live. The light still working does not make the switch safe. Leave the lighting breaker off and Book Now.
- Shocks from more than one placeA second shock from another switch, a tap, or a radiator means the earth may be live. Stop using those points. Book Now so the supply earth can be tested before the lights go back on.
- Heat, noise or a burning smellA warm plate, a buzz, or a smell of burning means a joint is arcing inside the box. Arcing is a spark across a loose connection. Leave the breaker off and do not open the switch to look.
- An RCD that drops againAn RCD is the switch that opens when current leaks away from the circuit. Reset it once only, and only if the board is cool and quiet. If it opens again, leave it off and Book Now.
What happens on a visit for a shocking light switch?
We isolate the lighting circuit first and test the switch before any part is changed. Other circuits stay on while that lighting circuit is off.
- Which switch and which breakerWe ask which switch shocked you, whether water was present, and whether a tap or another switch did the same. We switch off that lighting circuit at the fuse board. A tester confirms the switch is dead before any screw comes out.
- Tests on the dead switchWe check which conductor is live, which is neutral, and whether an earth reaches the plate. A second test looks for current leaking through the cable insulation. The readings separate a failed switch, a missing earth, a damaged cable and a live supply earth.
- Earthing and bondingEarthing is the path that should carry a fault away from you. Bonding is the conductor that links metal pipes and taps to that earth. We check both, and we check that the supply can carry the load, before any further price is written.
- The repair or a breaker left offWe tell you the failed switch, joint, cable or supply earth before a part is fitted. The repair starts after you accept it. We then test the circuit again. A minor works certificate records an alteration, and our NAPIT registration is printed on it. If the circuit should not be switched on, we leave its breaker off.
What does a visit for a shocking light switch cost?
The price covers the visit, isolation of the lighting circuit, tests at the switch and on the earth, and leaving that circuit switched off or back on after a sound test. A new switch, more time tracing the cable, or a minor works certificate changes the price. A new fuse board is written as its own price when the board has failed.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- A switch or a length of cable is added only when the readings show that part has failed.
- A new fuse board is a separate written price when the breaker or the board has failed.
- An out of hours visit is priced as Emergency electrician, separate from fault finding during opening hours.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan the rest of the lights stay on?
Yes, when those lights sit on another breaker and nobody felt a shock from their switches. We isolate only the circuit that feeds the switch which shocked you. That breaker stays off until the tests show the circuit can be switched on.
Will you change the switch on the visit?
We change it on the visit when the tests show the switch has failed and you accept that repair. A switch that tests sound stays on the wall. If the cable or the earth is the failed part, we price that work before it starts.
What paperwork do I get?
A minor works certificate follows if we alter the circuit. It records the test results and our NAPIT registration. An EICR is an Electrical Installation Condition Report for every circuit in the property, and it is booked as its own job.
What if a tap gave me a shock too?
A shock from a switch and a tap means fault voltage may be on the earth. We test earthing and bonding before we treat the switch as the only fault. Affected circuits stay off if that earth cannot be left connected.
Should I book if it was only a tingle?
Yes. A tingle is a smaller current from the same kind of fault. Wet hands or a worsening joint can turn it into a harder shock. Book Now and leave that switch unused.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
- Electrical arcing or crackling soundA crackling noise is a spark at a loose or burnt joint, so that circuit stays off until it is tested.
Sources
- Electrical Safety First: first aid for electric shock
- HSE: work using electrically powered equipment (RCD)
- IET: Broken PEN
- St John Ambulance: electric shock
Updated 16 November 2026