Hypervolt EV chargers in Peterborough
Lighting Electrical installs and repairs Hypervolt home EV chargers in Peterborough, fitting each unit on a dedicated circuit with a CT clamp and handing it over tested and linked to the Hypervolt app.
Calls answered 24/7
- 10 years trading
Hypervolt chargers we install, fix and service
Hypervolt makes smart home chargers for electric cars. We mount them, wire them on their own circuit, set up the clamp that measures household demand, trace their faults and check them over.
- Hypervolt Home 3 and Home 3 ProBoth are 7.4kW chargers for a single phase home supply. Each comes with a fixed lead or with a Type 2 socket for your own cable. We run a dedicated feed from the consumer unit, the panel of breakers inside the house, and connect the charger to the app over wifi.
- Solar mode and load balancingA CT clamp is a clip on sensor around the cables leaving the meter. It tells the Hypervolt how much the house is drawing, so charging slows before the main fuse is overloaded. With panels on the roof, the same clamp lets the charger run from surplus generation.
- Faults and warnings we fixThe light ring on the front changes colour to show the charger's state, and the app names the fault. We fix chargers stuck offline, PEN fault lockouts, DC leakage trips, breakers that drop as a charge begins, and worn leads or plugs. A PEN fault is a break in the shared neutral and earth from the street.
- What a Hypervolt service involvesSoftware reaches the charger through the app, so our check covers the hardware. We look at the lead and plug for cracks, the glands and casing for water, and time the trip of the RCBO feeding it. An RCBO is a combined breaker and earth leakage device. We also compare the clamp reading with the meter.
What does each electrical service involve on a Hypervolt charger?
EICR
from £150
The Hypervolt circuit is fixed wiring, so the electrical safety report, called an EICR, includes it. We test its RCBO trip time, insulation and earth, and note whether the charger's built in PEN fault detection stands in for an earth rod.
Consumer unit replacement
from £450
A new consumer unit gives the Hypervolt feed a fresh RCBO of the right type. We switch the charger off before isolating, refit the clamp if the meter tails were disturbed, and watch the light ring come back before we leave.
House rewiring
from £2,400
A rewire is the easiest moment to move a Hypervolt or run a longer feed to the drive. If the existing charger circuit tests sound, it lands on its own marked way in the new board.
Electrical fault finding
from £75 an hour
We read the light ring colour and the app message first. Then we measure supply voltage, earth and insulation on the charger circuit. Those readings show whether the charger, its cable or the car is at fault before any part is changed.
Lighting installation
from £65
Lighting work leaves the Hypervolt alone. A light over the charging spot is fed from a lighting circuit, never from the charger's dedicated cable.
Hypervolt EV charger installation
from £750
This is the main Hypervolt job. We check the main fuse, the earthing and the wifi signal at the wall, then fit the charger on its own circuit with an RCBO and isolator. The CT clamp goes on the meter tails, the app is linked and a test charge runs if the car is home.
Socket installation
from £85
A Hypervolt never needs a socket to run. An outdoor socket near it for a pressure washer goes on a separate protected circuit, not a spur off the charger cable.
Emergency electrician
from £90 an hour
A Hypervolt that smells hot, shows scorching or keeps tripping its breaker gets its circuit isolated out of hours. The rest of the house stays live, and the repair follows once testing names the cause.
Electrical testing and certificates
from £95
PAT testing is for plug in appliances, so a fixed Hypervolt sits outside it. The portable charging lead that came with the car can be tested on the same visit and listed on the PAT record.
Smoke alarm installation
from £110
Smoke and heat alarms run on their own feed and never connect to the charger. Where a Hypervolt hangs in an integral garage, we fit a heat alarm there rather than a smoke alarm.
Appliance and heating connections
from £120
Before connecting a cooker or electric heater in a house with a Hypervolt, we add up the loads against the main fuse rating. The CT clamp lets the charger back off while the new appliance draws power.
Solar panel and battery storage installation
from £5,500
With panels fitted, a Hypervolt can charge the car from spare generation. We place the CT clamp so it reads true grid import and export, then set solar mode in the app with you.
Forklift charger installation
from £700
Hypervolt does not make forklift chargers. We fit the industrial charger and its isolator at the warehouse bay, on a circuit from the site distribution board.
Commercial Lighting Installation
from £65
Commercial lighting does not touch a Hypervolt. At premises with a charger for staff or visitors, new fittings take their own breakers, so a lighting fault never stops a car charging.
Starlink installation
from £350
A Starlink dish has nothing to do with the charger. A Hypervolt needs wifi at the wall to stay online, so we can site the Starlink router where its signal reaches the drive.
Light switch or dimmer replacement
from £60
Changing a switch or dimmer leaves the Hypervolt untouched. Only the lighting breaker goes off, so a scheduled overnight charge carries on.
Minor works certificate
from £95
Shifting the Hypervolt isolator or lengthening its feed is a small alteration to an existing circuit. We retest that circuit and record its protective device and readings on a minor works certificate.
Extractor fan installation
from £180
An extractor fan does not involve the Hypervolt. We wire the fan from a lighting circuit or a fused spur, a wall outlet holding its own fuse, and the charger feed is never opened.
Electric shower installation
from £220
An electric shower pulls a heavy current, as a charging car does. We size the shower circuit, compare both loads with the main fuse rating, and confirm the clamp makes the Hypervolt ease off while the shower runs.
Emergency lighting test & certificate
from £150
Emergency lighting tests involve no Hypervolt equipment. On a site with chargers, only the feed to the emergency fittings is cut, so cars plugged into a Hypervolt keep charging.
Immersion heater repair
from £70 an hour
Immersion work leaves the Hypervolt circuit live. We isolate just the immersion, test the element and thermostat, and replace the part that failed.
Battery storage installation
from £4,500
A home battery changes what the clamp sees. We fit the battery on its own way and place the Hypervolt clamp so the charger reads the grid and never mistakes battery discharge for spare power.
Fire alarm system installation
from £1,400
Fire alarm panels share nothing with a Hypervolt. The panel gets a dedicated, labelled breaker, kept apart from any charger circuit in the building.
Cherry picker hire
Cherry picker hire does not involve the Hypervolt. A wall charger sits at hand height, so we operate the platform for high lights, signs and sensors instead.
Why has my Hypervolt gone dark in a power cut?
- No power in the whole houseA dark light ring during a full outage means the charger has lost its supply along with the house. If the street is lit, we look for a tripped main switch or RCD. Once power returns, the Hypervolt should rejoin wifi by itself, and we check that it does.
Other brands we work on
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Follow your job from booking to receipt
See when we're on our way, get your job report the moment we finish, and pay in seconds.
Track us on our way
See us on the map with a live arrival time.
Your job report, same day
See exactly what was done as soon as we finish.
Invoice and receipt in one place
Pay online in seconds, and your receipt is always there when you need it.
Why choose Lighting Electrical
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan you install a Hypervolt Home 3 charger?
Yes. We fit it on a dedicated circuit with its own RCBO, put a CT clamp on the meter tails and link the charger to the Hypervolt app. You choose the fixed lead or the socket version before the unit is ordered.
Does a Hypervolt need an earth rod?
Usually not. The charger has PEN fault detection built in, so it stops charging if the street neutral and earth fail. We test the earthing at the property first and say if anything more is needed.
Why is my Hypervolt stuck offline in the app?
It has lost its wifi link, often after a router change or because the signal at the wall is weak. We check the signal at the charger, test its circuit and reconnect it to the app.
Can a Hypervolt charge my car from my solar panels?
Yes, once the CT clamp sits where it reads power flowing to and from the grid. Solar mode then sends spare generation to the car. We set it up and show you how to change modes in the app.
Can you move my Hypervolt when I move house?
Yes. We disconnect it, leave the old circuit safe and fit the charger on a new dedicated feed at your new address. The clamp goes on the new meter tails and the charger is linked to the app again.




