Hager consumer units in Peterborough
Lighting Electrical fits and replaces Hager consumer units in Peterborough, putting each circuit on its own RCBO so one fault switches off one circuit, not the whole house.
Calls answered 24/7
- 10 years trading
Which Hager consumer units do we fit and repair?
We fit Hager metal consumer units in homes and Hager distribution boards in shops and workshops. We also trace trips and test the devices inside them. Every board is tested before the power goes back on.
- Hager Design 10 metal consumer unitsHome boards go in a metal enclosure, because the wiring regulations ask for a non combustible board in a dwelling. We fill it with Hager RCBOs. Each RCBO is a breaker and an earth leakage device in one, so a single circuit trips on its own.
- Hager arc fault and surge devicesWhere the board needs them, we add a Hager surge protection device, which shields electronics from voltage spikes. We also fit arc fault detection devices, called AFDDs, which cut a circuit when they sense arcing at a loose joint or a damaged cable.
- Hager trips and fault indicatorsWe trace an RCD or RCBO that will not reset and a main switch that keeps dropping out. On a Hager AFDD, a small indicator light shows the cause of the last trip. Testing finds the circuit behind the trip before any device is swapped.
- What a Hager board service involvesA consumer unit has no yearly service. We check that terminals are tight and look for heat marks on the busbar, the copper bar that feeds the breakers. Then we time each RCD trip and show you the test button to press every three months.
What do we do on Hager boards in each service?
EICR
from £150
We open the Hager board, check every terminal and device, and time each RCD and RCBO trip. The report lists any Hager device that fails, along with the rest of the fixed wiring.
Hager consumer unit replacement
from £450
We take out the old fuse board and fit a Hager metal consumer unit with RCBOs. Every circuit is tested and marked before the supply goes back on.
House rewiring
from £2,400
A rewire finishes at a new Hager consumer unit. Each new circuit lands on its own marked Hager RCBO, sized for the cable it protects.
Electrical fault finding
from £75 an hour
We start testing at the Hager board, reading which RCBO or RCD tripped. When a Hager AFDD light points to arcing, we follow that circuit to the failed joint.
Lighting installation
from £65
New lights on an existing circuit only need the Hager board to isolate that circuit. A new lighting circuit gets its own Hager breaker and a marked way at the board.
EV charger installation
from £750
A charge point needs a spare way, a free slot in the board. We fit a Hager RCBO for it, or add a small Hager enclosure beside a board that is already full.
Socket installation
from £85
Sockets and switches are fitted at the wall, not in the board. Before we wire a new point in, we check that the Hager RCBO on that circuit can carry it.
Emergency electrician
from £90 an hour
When a Hager main switch or RCD will not stay on, we isolate the faulty circuit at the board. The rest of the house can then be switched back on safely.
Electrical testing and certificates
from £95
PAT testing checks plug in appliances, so it does not touch the Hager board. Insulation tests on each appliance find the kettle or heater that keeps tripping an RCD.
Smoke alarm installation
from £110
Mains smoke and heat alarms need a feed from the board. We connect them to a lighting circuit used every day, or to their own Hager breaker.
Appliance and heating connections
from £120
A cooker or electric heater needs a circuit rated for its load. Before we connect the appliance, we check that the Hager breaker on that circuit matches it.
Solar panel and battery storage installation
from £5,500
Solar panels feed the house through a dedicated way. We fit a Hager breaker or a small Hager board for the inverter, put an isolator nearby, and mark the main board to show it carries solar generation.
Forklift charger installation
from £700
Forklift chargers often run on a three phase supply. We fit a Hager three phase distribution board, or a dedicated Hager breaker and isolator, for the charging bay.
Commercial Lighting Installation
from £65
Shop and office lights run from a commercial distribution board. On a Hager board, we add or change breakers for the new lighting circuits and mark each way with the area it feeds.
Starlink installation
from £350
A Starlink dish does not involve the board. We mount the dish and run its cable. Where a new socket is wanted, it goes on a circuit that is already protected at the board.
Light switch or dimmer replacement
from £60
Changing a switch or dimmer is work at the wall, not in the board. We switch off the lighting breaker at the Hager board, fit the new control, then switch the breaker back on to test it.
Minor works certificate
from £95
The certificate records the breaker that protects the altered circuit. On a Hager board, we read the device type and rating off it and write both on the form.
Extractor fan installation
from £180
A fan joins the lighting circuit or a fused spur, which is a switched outlet with its own fuse. We isolate that circuit at the Hager board while the fan is wired in.
Electric shower installation
from £220
An electric shower draws a heavy load on its own circuit. We fit a Hager RCBO rated for the shower, or a separate Hager enclosure when the board has no free way.
Emergency lighting test & certificate
from £150
Emergency lights are tested by cutting their mains feed. On a Hager board we switch off the breaker for those fittings, watch each lamp, then switch the breaker back on.
Immersion heater repair
from £70 an hour
A failed immersion element often trips the Hager RCD or RCBO on that circuit. We test the element at the cylinder, replace the failed part, then check that the device at the board stays on.
Battery storage installation
from £4,500
A home battery connects through its own protected way. We fit a Hager breaker or a small Hager board for the battery inverter, then mark the main board to show it has a second supply.
Fire alarm system installation
from £1,400
A fire alarm panel needs its own mains feed. We supply it from a dedicated Hager breaker, marked in red so nobody switches the panel off by mistake.
Cherry picker hire
The cherry picker itself has nothing to do with the board. From the platform we reach high lighting, and any new high level circuit gets its own Hager breaker at the board.
Why has the whole house lost power?
- No power in the whole houseLook at the Hager board first. If the main switch or an RCD has dropped, reset it once. If it trips again, we trace the circuit that keeps switching it off.
Other brands we work on
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Follow your job from booking to receipt
See when we're on our way, get your job report the moment we finish, and pay in seconds.
Track us on our way
See us on the map with a live arrival time.
Your job report, same day
See exactly what was done as soon as we finish.
Invoice and receipt in one place
Pay online in seconds, and your receipt is always there when you need it.
Why choose Lighting Electrical
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan you replace my old fuse box with a Hager consumer unit?
Yes. We remove the old fuse box and fit a Hager metal consumer unit with RCBOs. Every circuit is tested and marked before the power goes back on, and the change is notified through NAPIT.
My Hager RCD keeps tripping. Is the board faulty?
Rarely. A trip usually means the device has caught a fault further along a circuit. We test each circuit to find the appliance, cable or accessory that is leaking current before we change anything at the board.
Do I need arc fault devices in my Hager board?
The wiring regulations recommend AFDDs on many new circuits, especially those feeding sockets. We look at the house and its circuits, then tell you which circuits would gain from one.
Can my Hager board take an EV charger?
Often it can, if there is a spare way and the supply can carry the extra load. We check the incoming supply, the earthing and the free ways first. If the board is full, a small Hager enclosure beside it can take the charger circuit.
How often should I test the RCDs in my Hager board?
Press the test button marked T every three months. The device should switch off straight away. If it stays on, the RCD needs testing and replacing before that circuit is used again.