Ohme

Ohme EV chargers in Peterborough

Lighting Electrical fits Ohme Home Pro and ePod chargers in Peterborough, sets the CT clamp on the meter tails and leaves each charger on a tested circuit, paired with the Ohme app.

Calls answered 24/7

  • 10 years trading

Which Ohme chargers do you fit and repair?

We fit and repair Ohme home chargers for electric cars. We also set up the load balancing sensor that comes with them, trace their faults and check them over. Every Ohme goes on its own circuit and is tested before the first charge.

  • Ohme Home Pro and ePodThe Home Pro is a tethered charger, with the lead fixed to the unit and a small screen on the front. The ePod has a socket and no screen, so you plug in your own Type 2 cable. Both run from their own circuit at the consumer unit, which is the box of breakers where every circuit starts.
  • Load balancing with a CT clampA CT clamp is a sensor clipped round the meter tails that reads how much power the house is drawing. We fit it so the Ohme slows the charge when the cooker, shower and car together would overload the main fuse.
  • Faults we fix on Ohme chargersWe fix chargers that show offline in the Ohme app, PEN fault warnings, breakers that trip when a charge starts, and damaged leads or connectors. A PEN fault is a break in the combined neutral and earth of the street supply. The Ohme detects it and stops charging. We read the message on the app or screen, then test the supply and the circuit.
  • What servicing an Ohme involvesOhme sends firmware updates over the internet, so a service is a hands on check. We look over the lead, the connector and the cable glands for wear or water. We also test the RCBO, which is a breaker with its own earth leakage protection, and confirm the CT clamp reading in the app.

Ohme’s website

What do you do on an Ohme charger in each service?

EICR testing in Peterborough

EICR

from £150

The Ohme circuit is part of the fixed wiring that an EICR covers. An EICR is the electrical safety report on a property. We test the circuit's RCBO, earth and insulation at the board, and we note whether the charger's own PEN fault protection takes the place of an earth rod.

Fuse board replacement

Consumer unit replacement

from £450

When the board changes, the Ohme circuit moves onto a new RCBO. If the work disturbs the CT clamp, we refit it round the meter tails. We switch the charger back on last and check that it reconnects in the app.

House rewiring in Peterborough

House rewiring

from £2,400

If the existing Ohme circuit tests sound, a rewire keeps it and lands it on a marked way in the new consumer unit. If you want the charger on another wall, we run its new feed while the floors are up.

Electrical fault finding

Electrical fault finding

from £75 an hour

When an Ohme stops charging or trips its breaker, we test the circuit, the supply voltage and the earth before opening the unit. The fault message in the app and our readings together show whether the charger, the cable or the car is causing it.

Lighting installation

Lighting installation

from £65

Lighting work does not touch the Ohme charger. A driveway light near the charger goes on its own circuit, so a lighting fault cannot stop a charge.

EV charger installation

Ohme EV charger installation

from £750

This is the main Ohme job. We check the main fuse and the earthing, then mount the Home Pro or ePod on a dedicated circuit. We fit the CT clamp and pair the charger with the Ohme app before a test charge.

Socket and switch installation

Socket installation

from £85

An Ohme needs no socket. If you want a weatherproof outdoor socket beside it for a jet washer, we fit it on a separate protected circuit and never take it as a spur from the charger feed.

Emergency electrician

Emergency electrician

from £90 an hour

If an Ohme charger is scorched, hot or keeps tripping out of hours, we isolate its circuit so the rest of the house stays safe to use. Once the cause is clear, we repair or replace the unit.

Electrical testing and certificates

Electrical testing and certificates

from £95

PAT testing covers portable kit, so a fixed Ohme charger falls outside it. On the same visit we can PAT test the three pin charging lead that came with the car and add it to the record.

Fire and smoke alarm installation

Smoke alarm installation

from £110

Smoke and heat alarms do not connect to an Ohme. If the charger is in an integral garage, we can fit a heat alarm there. Car exhaust in a garage can set off a smoke alarm.

Appliance and heating connections

Appliance and heating connections

from £120

A cooker, a heater and an Ohme running together can overload the main fuse. When we connect a new appliance, we check that the CT clamp reads the whole house, so the charger slows down while the appliance is on.

Solar and battery storage

Solar panel and battery storage installation

from £5,500

The solar inverter and the Ohme each get their own circuit. We place the CT clamp so it reads the power drawn from the grid correctly once generation is connected. We also label the board to show both supplies.

Forklift charger installation

Forklift charger installation

from £700

Forklift chargers are industrial units with no Ohme parts. We fit the charger and its isolator at the warehouse bay. Ohme units are for cars at homes and small workplaces.

Commercial lighting installation

Commercial Lighting Installation

from £65

Commercial lighting has no link to an Ohme. At a workplace with an Ohme on a staff bay, we keep the lighting circuits separate and mark the charger way clearly on the distribution board.

Starlink installation

Starlink installation

from £350

Starlink equipment does not involve the Ohme. We mount the dish and run its cable. If your Ohme struggles to stay online, we can place the router where its wifi reaches the charger wall.

Light switch or dimmer replacement

Light switch or dimmer replacement

from £60

A switch or dimmer swap involves no Ohme equipment. We isolate only the lighting circuit, so any charge scheduled on the Ohme keeps running while the new control goes in.

Minor works certificate

Minor works certificate

from £95

Small changes to an Ohme circuit go on a minor works certificate, such as moving the isolator or extending the cable. We test that circuit and write the RCBO rating and the readings on the form.

Extractor fan installation

Extractor fan installation

from £180

An extractor fan has no link to an Ohme. We wire the fan from the lighting circuit or from a fused spur, which is a switched outlet with its own fuse. The charger circuit stays untouched.

Electric shower installation

Electric shower installation

from £220

An electric shower and an Ohme are the two heaviest loads a house usually has. Before adding a shower, we check that the main fuse can carry both. We also confirm the CT clamp slows the charger while the shower runs.

Emergency lighting test & certificate

Emergency lighting test & certificate

from £150

An emergency lighting test involves no Ohme equipment. At a workplace with Ohme bays, we cut the mains only to the emergency fittings, so cars on charge carry on charging.

Immersion heater repair

Immersion heater repair

from £70 an hour

An immersion repair does not touch the Ohme. We isolate the immersion circuit and test the element and thermostat. The charger circuit stays live throughout.

Battery storage installation

Battery storage installation

from £4,500

A home battery changes what the CT clamp sees at the meter tails. We fit the battery on its own way and position the clamp so the Ohme reacts to real grid demand rather than to the battery's output.

Fire alarm system installation

Fire alarm system installation

from £1,400

A fire alarm panel takes its own dedicated feed and uses no Ohme parts. In a building with Ohme bays, we keep the panel supply apart from the charger circuits, so switching one off never affects the other.

Cherry picker hire

Cherry picker hire

Cherry picker hire involves no Ohme equipment. We bring the machine and operate it for high lights and signs. Ohme chargers sit at wall height and need no platform.

Why is my Ohme charger off when the house has no power?

  • No power in the whole houseA blank Ohme screen during a whole house outage means the charger has lost power along with everything else. We check the main switch and the RCDs, which cut power when current leaks to earth, and the street supply. We switch the charger circuit on last and confirm it reconnects in the app.

Other brands we work on

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Follow your job from booking to receipt

See when we're on our way, get your job report the moment we finish, and pay in seconds.

  • Track us on our way

    See us on the map with a live arrival time.

  • Your job report, same day

    See exactly what was done as soon as we finish.

  • Invoice and receipt in one place

    Pay online in seconds, and your receipt is always there when you need it.

Why choose Lighting Electrical

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Ohme charger questions

Still have a question?

Can you install an Ohme Home Pro or ePod?

Yes. We fit both on a dedicated circuit, add a CT clamp for load balancing and pair the charger with the Ohme app. You choose between a tethered lead and a socket before we order the unit.

Do I need an earth rod for an Ohme charger?

Usually not. Ohme chargers detect a PEN fault themselves and stop the charge, so the existing earth often serves. We test the earthing first and tell you if your supply needs more.

Why does my Ohme charger show offline?

The charger has lost its internet link. A weak wifi signal at the wall or a changed router password are common causes. We check the signal at the unit and test the circuit, then reconnect the charger in the app.

Can you move my Ohme charger to another wall or a new house?

Yes. We disconnect the unit, make the old circuit safe and refit the charger on a new circuit where you want it. At a new property the CT clamp goes on the meter tails there, and we pair the charger with the app again.

Will my fuse board take an Ohme charger?

It needs a spare way, plus a main fuse that can carry the charger along with the rest of the house. The CT clamp lets the Ohme slow down when the house is busy, which often avoids a supply upgrade. If the board is full, we quote a board change as a separate job.

Book or ask a question

Calls answered 24/7