Circuit breaker keeps tripping
A breaker that keeps tripping still has a fault on its circuit. Lighting Electrical in Peterborough tests that circuit at the fuse board and tells you what failed before a part is changed.
Calls answered 24/7
- 10 years trading
Why does a circuit breaker keep tripping?
A circuit breaker keeps tripping because the fault that opened it is still there. The cause is too much load, a short, current leaking to earth, or a protective device that has worn out.
- Too much load on one circuitA miniature circuit breaker is the switch that opens when current rises above its rating. A kettle, a heater and a toaster on one circuit push the current over that rating. The breaker opens to keep the cable from overheating.
- A short in the cable or a socketA short means a live conductor is touching neutral or earth. Current surges and the breaker opens straight away. A crushed cable, a loose strand or a burnt socket terminal lets those conductors meet.
- Current leaking to earthA residual current device, an RCD, opens when some current leaves the circuit and returns through earth. Water in an outside socket, a failed heating element or a damaged cable gives the current that path. An RCBO does the same earth check and the overcurrent check for one circuit only.
- A protective device that opens too earlyA worn breaker or RCD opens below the number marked on its front. We test that device before we treat the cable as the fault. Where the device has failed on a Hager, Wylex or Contactum board, the replacement matches that board.
- One RCD opening several circuitsSome boards place several breakers under one RCD. A leak on a single circuit then drops the lights and the sockets together. Each breaker still looks closed while the wider RCD sits open. The tests separate those circuits and show the one that leaks.
What can you check safely when a breaker keeps tripping?
You can read the fuse board, also called a consumer unit, unplug what is on the circuit and reset once. The cover stays on, and you do not open an appliance or touch a cable.
- Which switch is openLook through the closed cover and read the label beside the switch that has dropped. The label names sockets, lights, a cooker or a shower. The wider switch is the RCD. Write down which switch is open before you move it.
- One reset with the plugs outUnplug every appliance on that circuit, including any extension lead. When the board is cold and silent and there is no smell of scorching, lift the switch once. If it opens again at once, leave it down and Book Now.
- Plugging back in one at a timeA switch that stays up means you can plug each appliance back on its own. Stop at the one that opens the switch and leave that plug out. The other appliances can stay in use on a switch that holds.
- Covers, pipes and appliance casesLeave the consumer unit cover screwed on. Leave kettles, heaters and fridge cases shut. Do not touch gas pipes, refrigerant pipes on a fridge or freezer, or any mains conductor.
When should you book if the breaker keeps tripping?
Book Now when a single reset will not hold, or when the board is hot, noisy or smelling of scorching. Water around a socket is a reason to book as well.
- The switch drops with every plug outThe fault sits in the cable, a socket, a joint or the protective device once every appliance is unplugged. Leave the switch off. Another reset warms the conductors.
- Heat, noise or a smell of scorchingWarm plastic, a buzzing noise or scorching at the board means a connection is overheating. Leave the tripped switch off. Book Now and keep the cover on.
- Lights and sockets drop togetherSeveral circuits going off at once means the RCD has opened. A leak on one of its circuits, or a failed RCD, produces that pattern. Leave the RCD off so the visit can separate the circuits on test.
- Water near a socket or fittingRain in an outdoor socket, a flooded floor or a drip on a fitting sends current to earth and opens the RCD. Stay clear of the water and leave the switch off.
What happens on a visit for a tripping breaker?
We read the board with you, test the circuit that opens, tell you the finding, and carry out the repair after you accept it. The breaker stays off if that circuit cannot be left on.
- What drops and when it dropsWe look at the fuse board with the cover still on and record each switch position. We ask what was in use and whether the trip follows rain or a particular appliance. A Hager, Wylex or Contactum name on the door is written down.
- Tests with the circuit switched offWe switch off the circuit that trips and confirm it is dead before any cover comes off. An insulation test looks for a path for current between conductors or to earth. A continuity test looks for a broken conductor or a short. Together the readings separate an appliance, a cable, a joint and the device.
- The finding before a price for more workWe tell you the failed part before a replacement starts. We measure earthing, which is the path that fault current takes back to safety, and bonding, which connects pipework to the earth, plus spare capacity on the supply. Any later price uses those measurements. An appliance that causes the trip stays unplugged.
- The repair and the certificateAfter you accept, we repair the failed joint, accessory, cable or device. A second test follows on that circuit. Where this repair needs paperwork, Lighting Electrical completes the minor works certificate as a NAPIT registered contractor. We leave the breaker off when switching the circuit on would be unsafe.
What does a tripping breaker visit cost?
The price covers tests on the tripping circuit, a diagnosis spoken on site, and putting the failed part right once you have accepted the work. The work is hourly fault finding. Extra time, a failed part, or a minor works certificate alters the bill. Fuse board replacement, when the board itself has failed, is written up separately. Emergency electrician attendance is priced on its own.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A failed breaker, socket or cable is added to the bill, and we fit Hager, Contactum or Wylex where that is the board make.
- We put a minor works certificate on the bill only when the finished repair needs one.
- An EICR, meaning an electrical installation condition report on the whole installation, carries a separate price from this repair.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWill you replace the breaker before finding the fault?
No. Testing comes before any breaker is removed from the board. We name the failed appliance, cable, joint or device, and the repair begins only once you accept it. A device that still passes the test stays put.
Will a new fuse board stop the breaker tripping?
Fuse board replacement follows only when the tests show the board or its device has failed. A board that passes stays, and the leaking appliance or damaged cable is repaired on that board. The replacement is then a separate written price.
What certificate do I get after the repair?
A repair that changes the circuit comes with a minor works certificate showing the test results for that work. Lighting Electrical is NAPIT registered and issues that certificate. An EICR is a different report on the whole installation, priced on its own.
Can you find a trip that only happens sometimes?
A trip that is absent during the visit can still leave a trace on the board or the cable. We follow that trace and tell you what the readings show. If the fault does not appear, we tell you those readings and which breaker to leave off.
Do you fix the fault during the visit?
The repair of the failed joint, accessory, cable or device takes place on the visit after you accept it. We test the circuit again after the repair. We leave the breaker switched off if the circuit cannot safely go back on.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
- Electric boiler trips the electricsAn electric boiler trips the electrics when its circuit leaks to earth or draws more current than its breaker allows.
Sources
- BS 7671: IET Wiring Regulations (18th Edition)
- Electrical Safety First: Safety Guidance
- IET: BS 7671 Guidance Publications
Updated 16 November 2026