Electric shock from the shower
An electric shock from the shower means current is reaching you through the water, the controls or the taps. Lighting Electrical in Peterborough isolates that circuit, tests the earth, and leaves the shower off until the fault is named.
Calls answered 24/7
- 10 years trading
Why does a shower give an electric shock?
Current from the shower is reaching your body through the spray, the controls or the taps. The fault sits in the shower circuit, the pipe bonds, or the safety switch that should have opened.
- A lost earth on the shower cableThe earth is the safety wire that should carry a fault away from you. If it is loose or broken, the shower case or the water can become live. You feel that when you touch the controls or stand in the spray.
- Pipe bonding that is missingBonding is the link that joins bathroom pipes and a metal bath to the earth at the fuse board. Without that link, a fault on another circuit can put a voltage on the taps. You feel it when a tap and the water are touched together.
- Water inside the shower caseAn electric shower passes water over a live heater. A failed seal lets that water onto live parts. The shock comes through the controls or the spray. Streaks on the outside of the case often show where water has been running.
- A heater leaking into the waterThe heater is the tube that warms the water as it passes. When the insulation in that tube fails, current leaks into the water. An RCD is the safety switch that should open on a leak. If it stays closed, the spray remains live.
- No safety switch for the showerA breaker is the switch on the fuse board that cuts power to one circuit. Some older boards feed the shower from a plain breaker with no RCD. That breaker opens on a heavy overload. A small leak through a person does not open it, so the shock continues.
What can I check safely after a shower shock?
You can switch the shower off at the fuse board and note where the shock was felt. The shower cover stays on and every screw stays in. You keep your hands off the taps while you are still wet.
- The shower switch on the fuse boardFind the breaker for the shower and switch it off with the handle on the front. Leave the cover screws in place. If you cannot tell which breaker feeds the shower, switch off the main switch on the front and leave the board like that.
- Where you felt the shockRecall whether it was the spray, the controls or the taps, and whether the shower was running. A shock only while it runs points to the shower circuit. A shock from the taps with the shower already off points to the pipes.
- The outside of the showerLook for water tracking down the case, brown marks, or a smell of burning. Leave the pull cord as it is. Do not take the cover off. Do not press the controls to see if the shock comes back.
- Other metal in the bathroomRecall whether a radiator or a tap tingled before you dried your hands. Keep that in mind, then stay clear of the metal. Do not hold a tap and the shower hose together for a second try.
When should I book for a shock from the shower?
Book Now after any shock or tingle from the shower, the spray or a bathroom tap. One event is enough. Leave the shower circuit off and do not run the water again to confirm it.
- You felt current from the showerA shock or a tingle through the spray, the hose or the controls means the circuit is unsafe. Leave the shower breaker off. Book Now before anyone washes in that room.
- The shower breaker will not holdYou switch it on and it opens straight away. The leak is still on the circuit. Another reset puts the fault back on for a moment. Leave the breaker off.
- The taps tingle with the shower offVoltage on the taps while the shower is off is coming from the pipes or from another circuit. Do not use those taps. Book Now so the bonds and the other circuits can be tested.
- Water, heat or a burning smellWater running into the case, a warm cover or a burning smell means live parts are damaged. Keep that circuit switched off. Keep the floor dry and stay away from the case.
What happens on a visit for a shower shock?
We switch off the shower circuit and name the failed part before the shower cover comes off. The shower stays off when the tests show it is unsafe to switch on. Circuits that test sound stay on.
- Where the shock was feltWe ask whether the spray, the controls or the taps gave the shock, and whether the shower was running. We read the fuse board with you and switch the shower circuit off. A tester shows the cable is dead before any cover is opened.
- Tests on the dead shower circuitAn earth test checks that the safety wire still joins the shower to the fuse board. An insulation test measures leaking current in the cable and the heater. An RCD test checks that the safety switch opens when current leaks.
- Pipes, bonding and the supplyWe test the main earth and the bonding on the pipes. We check that the supply can carry the shower load before we price any further work. Voltage that remains on the taps sends us to the other circuit that is leaking.
- The repair you acceptWe name the failed part and start the repair only once you accept the price. We test the circuit again after that work. A minor works certificate records the alteration and carries our NAPIT registration. If the shower has to stay off, electric shower installation is priced in writing next.
What does a shower shock visit cost?
The price covers the shower circuit tests, telling you what failed, and leaving the circuit off when it is unsafe. Extra time spent tracing voltage on the pipes changes the price. A fitted part, a minor works certificate, or a separate electric shower installation changes it as well. Emergency electrician attendance carries its own price, apart from electric shower installation.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- Testing the taps and another circuit takes longer than confirming a failed heater on a sound cable.
- A Mira shower or a new breaker is fitted only after the tests show that part has failed.
- A new fuse board is quoted on its own when the shower circuit has no RCD to open on a leak.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs a tingle from the shower still a shock?
Yes. A tingle means current is passing through your body, even when it feels small. Leave the shower breaker off and keep off the wet taps. Book Now so the circuit is tested before anyone uses the shower.
Will the lights stay on while the shower circuit is off?
Yes. We switch off the shower circuit and leave sound circuits on. Lights and sockets on other breakers keep working. The shower remains off if the tests show it is unsafe to switch back on.
Do you fit a new electric shower on the first visit?
Only when the tests show the unit has failed and you accept the price before we start. A sound shower stays on the wall. Electric shower installation is a separate job when a new unit is the repair.
What paperwork follows work on the shower circuit?
When we alter the circuit, a minor works certificate records the test results and our NAPIT registration. An Electrical Installation Condition Report looks at the whole installation and is arranged as its own booking.
Why do the taps shock me when the shower is off?
The pipes are carrying voltage from missing bonding or from another circuit. We test those bonds and trace the circuit that is leaking. The shower circuit can test sound while the taps are still live.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electrical arcing or crackling soundA crackling noise is a spark at a loose or burnt joint, so that circuit stays off until it is tested.
Sources
- Electrical Safety First: first aid for electric shock
- HSE: Electrical injuries
- HSE: Electricity, work using electrically powered equipment (RCD)
- IET: Part P (England and Wales) FAQs, notifiable work
Updated 16 November 2026