Why is my dimmer switch humming?
A humming dimmer means the lamps and the dimmer do not suit each other, or a joint in the switch is loose. Lighting Electrical in Peterborough tests the circuit and changes the dimmer when the dimmer itself is the fault.
Calls answered 24/7
- 10 years trading
Why does a dimmer switch hum?
A dimmer hums because the lamps and the dimmer do not match, or because a joint behind the plate is loose. The same hum appears when the lamps sit outside the load the dimmer is built for.
- Lamps that are not dimmableAn LED lamp is a low energy lamp with a small circuit inside the cap. Many of those lamps are built only for a plain on and off switch. On a dimmer that circuit buzzes and the light flickers.
- The wrong dimmer for the lampSome dimmers cut the front of each mains wave and suit older filament lamps. Others cut the tail of the wave and suit most LED lamps. Pairing the wrong dimmer with the lamp makes the plate hum.
- Too much or too little loadEvery dimmer has a highest load and a lowest load, written in watts. Too many lamps make the dimmer hum and run hot. One lamp below the lowest load does the same.
- Two dimmers on one lightA two way light has a switch at each end of a room or a stair. Only one of those switches can be a dimmer. A second dimmer on that light hums because the two modules fight.
- A loose joint in the dimmerA loose terminal in the dimmer arcs. Arcing is a small spark at the joint. That spark buzzes and warms the plate.
What can I check on a humming dimmer?
You can check the lamps, the sound and the plate with the screws left in. The fuse board cover stays on, and you do not touch the cables.
- The writing on the lampSwitch the light off and let the lamp cool. Read the sleeve. A lamp marked dimmable is built for a dimmer. A lamp with no such mark hums on a dimmer.
- Whether the hum is in the lamp or the plateMove the slider or the knob while you listen. A hum from the glass is the lamp. A hum from the plastic plate is the dimmer or a joint behind it.
- Heat in the plate and the number of lampsCount the lamps on that one dimmer. A plate that is warm at mid brightness is working hard. A plate that is hot, brown or smelling of burning needs that lighting circuit switched off at the breaker handle.
- A second switch for the same lightNote if another switch also works that light, and whether that second plate is a dimmer too. Two dimmers on one light are a known cause of hum. Leave both plates screwed on.
When should I book for a humming dimmer?
Book Now when the hum comes with heat, a burning smell or flicker, or when a dimmable lamp still leaves the hum in the plate.
- Heat, brown marks or a burning smellA hot plate, brown marks or a smell of burning means a joint is arcing. Switch that lighting circuit off with the breaker handle. Leave every screw in the plate.
- The hum stays after a dimmable lampA dimmable lamp is in the fitting and the plate still hums. The dimmer, the two way wiring or the load is then the cause. That needs a test with the circuit off.
- Flicker together with the humLamps that flicker while they hum are paired with the wrong dimmer, or they sit below the lowest load. The dimmer runs hot in that state. Book Now so the lighting circuit can be tested.
What happens on a visit for a humming dimmer?
We isolate the lighting circuit, test the dimmer against the lamps, and change the dimmer when the dimmer is the fault.
- The lamps and switches you have already triedWe ask which light hums and whether the sound sits in the glass or the plate. We ask what the lamp sleeve says and whether a second switch serves that light. We note any lamp you have already swapped.
- Tests with the lighting circuit offWe switch the lighting breaker off and test that the wires are dead before a screw comes out. We read the dimmer, the cable colours at the plate and the wattage of each lamp. Those readings separate a bad dimmer, a clashing lamp and a loose joint.
- A new dimmer when the dimmer has failedWhen the dimmer has failed we fit a Varilight, MK Electric or BG Electrical dimmer matched to the lamps. A sound dimmer stays in place when the lamp was the cause. Where two dimmers share a light, we leave one dimmer and make the other a plain switch.
- The circuit back on and the certificateWe switch the lighting circuit back on and run the dimmer from low to full. Where the dimmer was changed, a minor works certificate records that work and names our NAPIT registration. Before we price any further work we test earthing, which carries fault current away, and bonding, which joins metal pipes to the fuse board.
What does a humming dimmer cost?
The price covers testing the humming dimmer and the lamps on that circuit, then changing the dimmer once you accept it. One dimmer and one lamp takes less time than two way wiring or a fault further along the lighting cable. A replacement dimmer, a minor works certificate, or time spent past the plate changes the price.
From £65
Included when agreed
- Fitting of downlights, pendants, wall lights or outdoor lanterns you have chosen
- Connection onto the existing lighting circuit where that circuit is sound
- Replacement of the matching switch or dimmer for those lights
- Removal of the old fittings we take down
- A minor works certificate when the job needs one
Not included automatically
- A full house rewire or a new consumer unit
- Decorative plaster repair beyond the hole for the fitting
- Lamps, shades or fittings you have not bought or left for us
Ways to pay


- Pay by bank
- Bank transfer
- We add a Varilight, MK Electric or BG Electrical dimmer only when the test shows that dimmer has failed.
- Two way wiring, or more than one dimmer on the same plate, takes longer than a single plate with one knob.
- The minor works certificate sits in the price when the dimmer change needs one.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs a humming dimmer dangerous?
A soft hum from the lamp, with a cool plate and no burning smell, is the lamp and the dimmer disagreeing. Heat, brown marks or a burning smell mean a joint is arcing. Switch the lighting breaker off and Book Now.
Can I change the lamps myself?
Yes. With the switch off and the lamp cool, fit a lamp marked dimmable that sits inside the load written on the dimmer. If the plate still hums, the dimmer or the wiring needs a test.
Will you replace the dimmer on the same visit?
We name the failed part before anything is fitted. When the dimmer is that part, we fit the new one on the visit after you accept it. When the lamp is the fault, the existing dimmer stays.
Does a dimmer change come with a certificate?
A change of dimmer on the existing lighting circuit comes with a minor works certificate when the job needs one. The certificate records the tests for that dimmer and names our NAPIT registration. An EICR inspects the whole installation and is booked separately.
Will a new fuse board stop the hum?
Only if the lighting breaker or the fuse board is what the test finds at fault. A worn dimmer hums the same way on a new board. We price fuse board replacement on its own after the dimmer test.
Related problems
- Dimmer switch lights flickerFlicker on a dimmer comes from lamps that do not suit the dimmer, or from a loose joint on the lighting circuit.
- Dimmer switch not workingA dimmer stops working when its module fails, the lamps cannot dim, or the lighting circuit opens.
- Lights flickering after a new fittingA new fitting flickers when the lamp, the dimmer or a loose joint does not suit the lighting circuit.
- Pull cord light switch not workingA dead pull cord is a worn ceiling switch, a failed lamp, or an open lighting circuit.
- Why is my ceiling light buzzingA buzzing ceiling light is a loose joint, a failing lamp or a dimmer that does not suit the lamp.
- Wires hanging from the ceilingHanging ceiling wires are cable ends left outside a rose, and the lighting circuit is isolated before they are refitted.
Sources
- Electrical Safety First: Safety Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
- NICEIC: Householder Guidance
Updated 16 November 2026