Dimmer switch not working
A dimmer stops working when the module fails, the lamp cannot dim, or the lighting circuit opens. Lighting Electrical in Peterborough tests that control and replaces the module when the test shows it has failed.
Calls answered 24/7
- 10 years trading
Why has my dimmer switch stopped working?
A dimmer stops working because the module has failed, the lamps cannot dim, or the lighting circuit has opened. The module is the part in the switch that lowers power to the lamps.
- A worn dimmer moduleThe module sits inside the switch and lowers power to the lamps. Heat and constant use wear it out. The lamps then stay off, stick at full brightness, or cut out as the knob turns.
- Lamps that cannot dimLED lamps use light emitting diodes and need a dimmer made for them. A lamp that is not dimmable stays off or flickers. A dimmable LED still flickers when the module was built for old filament bulbs.
- Too much or too little loadLoad means the total power of every lamp on that dimmer. Added downlights push the module past the heat it can lose. One small LED can sit below the minimum an older module expects, so the lamp never comes on.
- A fault on the lighting circuitThe lighting circuit is the cable from the fuse board to the switches and lamps. The fuse board is the box of breakers for the house. A loose terminal or a broken wire on that cable leaves the dimmer dead. Other lamps on the same cable go dark with it.
- A second switch on the same lightTwo way switching means one lamp can be turned off from two places. A failed second switch stops the dimmer feeding the lamp. A loose strapper does the same. The strapper is the extra cable linking the two switches.
What can I check on a dimmer that has stopped?
You can read the lamp, move the dimmer and look at the lighting breaker while the switch stays on the wall.
- The marking on the lampSwitch the dimmer off before you change a lamp. Read the printing on the lamp or its box. A lamp with no dimmable marking can stay dark on a sound module.
- The dimmer turned fully upSlide or turn the control to the top of its range. Some modules light an LED only near the top. A knob that turns freely with no click is no longer switching the lamps.
- The lighting breaker with the cover onLook at the fuse board and leave the cover shut. The lighting breaker is the switch for the lamp circuit. If it is down, and the board is cool and silent, lift it once.
- A warm plate, a buzz or a smellA warm plate, a buzz or a burning smell means the module is getting too hot. Switch the dimmer off. Leave every screw in the plate.
When do I book for a dimmer that has stopped?
Book Now when a dimmable lamp still stays dark, or the dimmer is hot, buzzing or smelling of burning.
- A dimmable lamp still stays darkYou have fitted a lamp marked dimmable and set the control to full. The lamp stays off or will not fade. The module or the cable then needs a test with the power off.
- The dimmer plate is hot or buzzingA hot dimmer, a buzz from the plate or a burning smell means the module or a joint is failing. Switch the lighting circuit off using the breaker handle. Leave the plate screws where they are.
- Flicker or brightness stuck on fullThe lamps flicker, stay at full brightness, or work only from the other switch. That pattern points to the module or the cable between the switches. The circuit should stay off until it is tested.
What happens during a dimmer repair visit?
We turn the lighting circuit off, test the dimmer and the lamps, and fit a new module when the test shows the old one has failed.
- Which lamps and switches misbehaveWe ask if the lamps are dark, flickering, buzzing or stuck at full brightness. We ask which other switch feeds the same lamp. We view the fuse board with you and keep the cover on until we isolate the circuit.
- Dead tests on the dimmer and cableWe turn the lighting breaker off and confirm the cable is dead. Those tests separate a failed module, a bad lamp and a break in the cable. We tell you the result before a new part is fitted.
- A new module only if the old one failedWe fit a Varilight, MK Electric or BG Electrical dimmer that suits the lamps, after you say yes. A sound module stays on the wall. If the cable has failed, we write a separate price before any new length is put in.
- The range check and the certificateWe turn the circuit on and run the dimmer from low to full. When the job changes the circuit, we write a minor works certificate, the note of that change, under our NAPIT registration. Before a further price we check the earth return, the pipe link to the fuse board and the spare supply capacity.
What does a dimmer repair include?
The price covers a test of the dimmer and the lighting circuit, and a new module when that test shows the old one has failed. A different module, extra lamps, new cable or a minor works certificate changes the price.
From £65
Included when agreed
- Fitting of downlights, pendants, wall lights or outdoor lanterns you have chosen
- Connection onto the existing lighting circuit where that circuit is sound
- Replacement of the matching switch or dimmer for those lights
- Removal of the old fittings we take down
- A minor works certificate when the job needs one
Not included automatically
- A full house rewire or a new consumer unit
- Decorative plaster repair beyond the hole for the fitting
- Lamps, shades or fittings you have not bought or left for us
Ways to pay


- Pay by bank
- Bank transfer
- A replacement module is chosen from Varilight, MK Electric or BG Electrical.
- New cable or a fuse board change is priced on its own, apart from the dimmer.
- We read the dimmable marking on your lamps before the new module is chosen.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan you fit a dimmer I bought myself?
Yes, when that dimmer matches the lamps and the lighting circuit. We check the make, the load and the dimmable marking before it goes on the wall. A module that fights the lamps stays unused, and we name a Varilight, MK Electric or BG Electrical dimmer that suits them.
Will my LED lamps dim on a replacement?
Only when the lamps are dimmable and the module is made for them. An old dimmer built for filament bulbs can leave LED lamps dark or flickering. We match the module to your lamps or tell you that the lamps need to change.
Does a dimmer replacement come with paperwork?
Where replacing the dimmer changes the lighting circuit, the finished tests go on a minor works certificate with our NAPIT registration. An EICR is the report on the whole installation. That report is a different job.
Will you replace the dimmer before you test it?
No. We test the module, the lamps and the lighting circuit first. The dimmer comes off the wall only when the test shows it has failed. A sound dimmer stays put and we name the lamp or the cable instead.
Can one dimmer control a whole row of downlights?
Yes, when the combined lamp load sits inside what that module can handle. Too many lamps overheat the dimmer, and one small LED can sit below the minimum an old module needs. We count the lamps and fit a module for that load.
Related problems
- Dimmer switch lights flickerFlicker on a dimmer comes from lamps that do not suit the dimmer, or from a loose joint on the lighting circuit.
- Lights flickering after a new fittingA new fitting flickers when the lamp, the dimmer or a loose joint does not suit the lighting circuit.
- Pull cord light switch not workingA dead pull cord is a worn ceiling switch, a failed lamp, or an open lighting circuit.
- Why is my ceiling light buzzingA buzzing ceiling light is a loose joint, a failing lamp or a dimmer that does not suit the lamp.
- Why is my dimmer switch humming?Hum comes from lamps that do not suit the dimmer, or from a loose joint in the switch.
- Wires hanging from the ceilingHanging ceiling wires are cable ends left outside a rose, and the lighting circuit is isolated before they are refitted.
Sources
- Electrical Safety First: Safety Guidance
- NICEIC: Householder Guidance
- IET: BS 7671 Guidance Publications
Updated 16 November 2026