No RCD on an EICR: does it fail?
Whether a board with no RCD fails an EICR depends on which circuits lack protection. Lighting Electrical in Peterborough checks each circuit and replaces the consumer unit where an old board cannot take one.
Calls answered 24/7
- 10 years trading
- Local to Peterborough
Not sure? We'll check for you.
Why would an EICR fail a board with no RCD?
An EICR, short for electrical installation condition report, inspects a home's fixed wiring. Each unprotected circuit gets its own code: C2 makes the report unsatisfactory, C3 is a recommendation only.
- Sockets that could run outdoor equipmentA socket that could power a mower or hedge trimmer used outside needs 30mA RCD protection. An RCD (residual current device) switches the circuit off in a fraction of a second when current leaks to earth. Without one, the socket is coded C2.
- Sockets in a bathroom or shower roomWater and electricity make a fault to earth far more dangerous in these rooms. A socket there with no RCD is coded C2, so the report comes back unsatisfactory.
- An old fuse boxRewirable and cartridge fuses blow on overload but cannot sense current leaking to earth. One old board with no RCD at all can therefore raise several codes together.
- A board where only some circuits are protectedSome boards put an RCD over a few circuits and leave the rest bare. The inspector codes each bare circuit by what it feeds, so a gap on sockets weighs more than a gap on lights.
- An RCD that does not trip on testA fitted RCD that stays on when tested protects nobody. The inspector codes it C2 in its own right, even though the board looks as if it has protection.
What can a householder safely check?
Pressing the RCD test button is safe and worth doing every few months. Everything else stays with an electrician, because it means opening the board or touching the wiring.
- Press the test buttonThe test button carries a T on the front of the RCD. Press it and the switch should drop at once. Switch it back on and reset any clocks or timers that stopped.
- Treat a button that does nothing as a faultIf the switch stays up when you press test, the RCD is not protecting the circuits behind it. Leave it alone and ask an electrician to look at the board.
- Read the codes on your reportNote which circuits carry C2 and which carry C3. Having the circuit names to hand lets you ask about each one when the electrician arrives.
- Keep the cover shut and skip adaptorsNever open the consumer unit or fuse box. A plug in RCD adaptor protects only the appliance in it, so it does not give the circuit the protection the report checks for.
When is it time to book?
Book as soon as the report mentions a missing RCD or the test button does nothing. The unprotected circuits stay that way until the board is dealt with.
- The report lists C2 itemsLandlords in England must complete remedial work on C2 items within 28 days of the report, or by an earlier date the report names. Booking early leaves room for the board change and testing.
- The test button does nothingAn RCD that will not trip is a fault on its own. It needs checking before a real leak to earth finds it out.
- An EICR is coming and the board is oldA fuse box with no RCD will usually pick up several codes. Having it assessed first means you know what the inspector is likely to code.
What happens when Lighting Electrical visits?
We find out what protects each circuit first, explain what each code means, then replace the board only where the old one cannot be improved.
- Checking what protects each circuitWe look at which circuits sit behind an RCD and test that the RCD trips when it should. Circuits with no protection are listed against the codes on your report.
- Explaining each codeWe go through the C2 and C3 items circuit by circuit in plain words, saying what clears each one and what can wait.
- Replacing the board where neededWhen the old board cannot take RCD protection, our fuse board replacement fits a new consumer unit. It can use RCBOs, which combine a breaker and an RCD for a single circuit.
- Testing and paperworkWe test every reconnected circuit before it goes live. When the work is finished you receive an installation certificate showing what was done and the results.
What does a new consumer unit with RCD protection cost?
The price covers the new consumer unit, RCD or RCBO protection on the circuits, fitting it in place of the old board, testing every circuit and the paperwork. It changes with the number of circuits and the condition of the wiring behind them.
From £450
Included when agreed
- Isolation of the incoming supply and removal of the existing fuse board
- Supply and fitting of a new consumer unit with RCD or RCBO protection to suit the circuits
- Reconnection of existing circuits and labelling of each way
- Dead and live tests on the circuits that feed from the new board
- An electrical certificate and notification through NAPIT where the work requires it
Not included automatically
- Rewiring damaged cables found in walls, lofts or under floors
- New sockets, lights, showers or chargers that need extra circuits
- Making good plaster, paint or kitchen units around the cupboard
Ways to pay


- Pay by bank
- Bank transfer
- Each circuit needs its own protection and test, so a board with many circuits takes longer than one with a few.
- An outdoor supply, an EV charger or a shower on its own circuit adds to the board and the testing.
- Wiring that fails its tests must be put right before the new board is switched on, which changes the work and the price.
Consumer unit replacement near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 63
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWill an EICR fail if my fuse box has no RCD?
Often it will. Sockets that could run equipment outside are coded C2 when they lack an RCD, and nearly every socket in a house could. Gaps on lighting circuits are usually C3, which is advice only.
Does a plug in RCD adaptor stop the failure?
No. An adaptor only protects what is plugged into it, while the report looks for protection on the circuit itself at the board. The codes stay in place until the board is protected.
Do I need a new consumer unit to get RCD protection?
Usually, when the existing board is an old fuse box. These boards seldom have provision for RCD protection, so a modern consumer unit is how the codes are cleared. We fit them as part of our fuse board replacement.
Will I get a certificate after the board change?
Yes. We test every circuit and give you the electrical paperwork for the work when it is finished. It shows what was fitted and the test results.
Related problems
- Fuse box in the bathroom: is it legal?A consumer unit inside a bathroom is not permitted and has to be moved outside that room.
- Old fuse box: do I need to upgrade?An old fuse box needs an upgrade when it still uses fuse wire or has no residual current protection.
- Signs your fuse box needs upgradingA fuse box needs upgrading when it has fuse wire, no RCD, no spare ways, or a hot scorched cover.
- Still got rewirable fuses?A rewirable fuse box relies on fuse wire and has no residual current device, so the board is replaced and every circuit is tested.
- Unsatisfactory EICR: what happens next?An unsatisfactory EICR means a C1, a C2 or further investigation needs remedial work, and Lighting Electrical writes a price for those repairs.
- Aluminium wiring in the houseAluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.