Old fuse box: do I need to upgrade?

An old fuse box needs replacing when it still holds rewirable fuse wire or has no residual current device. Lighting Electrical in Peterborough fits a consumer unit and tests each circuit from it.

Calls answered 24/7

  • 10 years trading

Why does an old fuse box need an upgrade?

An old fuse box needs an upgrade when fuse wire or a missing safety switch leaves a leak or an overload on the circuit. How old the property is does not decide the upgrade on its own.

  • Fuse wire instead of a breakerA rewirable fuse is a short length of fuse wire in a carrier. The wire melts on a heavy overload. A small leak to earth can leave that fuse intact, so the circuit stays live. A breaker opens the same circuit with a switch you can reset.
  • No residual current deviceA residual current device, called an RCD, switches off when current leaks from the circuit to earth. Earth is the safety path that carries a fault away from you. Many older boards have no RCD, so a damaged lead or a wet socket does not cut the power.
  • A full board with no spare wayEach circuit needs its own way, which is one space on the board. An electric shower, an EV charger or extra kitchen sockets need a free way. A full fuse box cannot take that circuit until a larger consumer unit is fitted.
  • A cracked or scorched caseHeat from a loose terminal cracks a plastic or wooden case and leaves brown marks around the carriers. That case no longer holds a fault inside the board. The cover stays on until we isolate the supply and remove the unit.
  • An EICR that flags the boardAn Electrical Installation Condition Report, called an EICR, records missing RCD cover, damaged metal bars inside the board, or names that no longer match the circuits. We replace the unit when that report shows the board has failed those checks.

What can you check on an old fuse box?

You can look at the closed cover, the carriers and the test button. Leave every screw in place and keep your hands off the cables.

  • Fuse wire or breakers on the frontLook through the cover. Carriers that pull out and take fuse wire are an old fuse box. Small switches that click up and down are breakers. You leave every carrier in and you leave the cover shut.
  • Whether an RCD test button is thereAn RCD has a button marked T or Test on the front of the closed board. Press it once. If the switch drops, those circuits go off and you reset the switch. If the switch stays up, that RCD is not opening.
  • Heat, a smell or brown marksA warm cover, a buzz or a smell of burning means a joint inside is failing. Brown marks around a carrier mean the same. Leave the cover shut. Use the main switch on the front only if you can reach it without taking the cover off.
  • Spare spaces and the circuit namesRead the names printed on the front. Every space filled means there is no spare way for a shower, a charger or more sockets. A name that does not match the room shows the board has been altered. You only read the front.

When should you book an old fuse box upgrade?

Book Now when fuse wire keeps blowing, the board is hot or cracked, or an EICR asks for a new consumer unit. A board that is cool, quiet and already fitted with RCD protection can stay.

  • Fuse wire blows more than onceThe same lights or sockets die again after one new piece of fuse wire. The fault is still on the circuit. Further wire hides that fault and heats the carrier, so the circuit stays unused.
  • The board is hot, cracked or smellsHeat, a crack or a burning smell at the fuse box means a terminal is arcing. Arcing is a spark across a loose joint. Book Now and leave the cover screws in place.
  • A report or a new circuit needs a new boardAn EICR that records no RCD cover means the fuse box should be changed. A shower, a charger or a cooker with nowhere to connect needs a larger consumer unit. Fuse board replacement is a separate written price from any new circuit.

What happens on an old fuse box visit?

We isolate the supply, fit the consumer unit and test the circuits that leave it. The power stays off from isolation until those tests are finished.

  • The price, the tails and isolationWe confirm the written price with you. We look at the meter tails, the thick cables between the meter and the fuse box. We then isolate the incoming supply. Items stored in front of the cupboard need to be moved before that isolation.
  • The old board comes offWe remove the old fuse box. We fit a consumer unit from Hager, Wylex, Contactum, BG Electrical or MK Electric to match the circuits. We connect the tails and the earth, place each circuit on its breaker, and mark each way.
  • Tests, power back and the certificateWe test continuity, insulation and the RCD or RCBO. An RCBO is a breaker and an RCD together for one circuit. We restore the supply. We then check the lights and sockets. Replacing a fuse board is notifiable work, so we issue the certificate and notify it through NAPIT.
  • Circuits that fail the testsA scorched conductor or a poor earth reading stays as separate work with its own written price. Before that price we test the earth path and the bonds to metal pipes, and we check the supply can carry another load. Earthing is the fault path back to the board. Bonding is the link from those pipes to the earth.

What does an old fuse box upgrade include?

Fuse board replacement covers taking out the old fuse box, fitting a consumer unit with RCD or RCBO protection, and testing the circuits that run from it. A larger board, a steel case or a low cupboard changes the price. Scorched cables or a circuit that fails its test are written as further work. We confirm the written price before isolation.

From £450

Included when agreed

  • Isolation of the incoming supply and removal of the existing fuse board
  • Supply and fitting of a new consumer unit with RCD or RCBO protection to suit the circuits
  • Reconnection of existing circuits and labelling of each way
  • Dead and live tests on the circuits that feed from the new board
  • An electrical certificate and notification through NAPIT where the work requires it

Not included automatically

  • Rewiring damaged cables found in walls, lofts or under floors
  • New sockets, lights, showers or chargers that need extra circuits
  • Making good plaster, paint or kitchen units around the cupboard

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • The price covers the board change and the tests on the circuits that leave the new consumer unit.
  • A steel case, more ways, or a board in a low cupboard changes the price.
  • A shower, a charger or extra sockets are a separate job from the board change.

View the fuse board replacement cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

What do householders ask about an old fuse box?

Still have a question?

Do I need an upgrade if the fuse wire still works?

Yes, if the board has no RCD, because fuse wire does not open on a small leak to earth. A board that already has RCD or RCBO protection and passes its tests can stay. We say which applies after we see the closed cover and, where you have one, the EICR.

Will you replace a board that still has fuse wire?

Yes. We remove the rewirable fuse box and move the existing circuits onto breakers with RCD or RCBO protection. The supply stays off until the new consumer unit is tested, and you get the certificate for that change.

Do I get paperwork for a new consumer unit?

Yes. Replacing a fuse board is notifiable electrical work, which means the job is reported to the local authority. We issue the electrical certificate and notify it through our NAPIT registration. A circuit we switch off and do not change is written up from the test readings.

Can you change a fuse board in a rented house?

Yes. Landlords ask us after an EICR or when fuse wire keeps failing. We confirm the written price before isolation. The occupant clears the cupboard so we can reach the board.

Will a new consumer unit cure every dead circuit?

A new consumer unit restores a circuit only when the failed part is the board itself. A damaged cable, a scorched socket or a leaking appliance still needs its own repair, written separately. We name that part from the test results before we price it.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7