Fuse box in the bathroom: is it legal?
No. A fuse box in a bathroom is not permitted. Lighting Electrical in Peterborough fits the new consumer unit outside that room. Each circuit is tested from that board.
Calls answered 24/7
- 10 years trading
Why is a fuse box fitted in a bathroom?
A fuse box is in a bathroom because the board or the bath was fitted under older habits. Switchgear is not allowed in a room that contains a bath or shower.
- The bathroom was built around the boardThe consumer unit was already on that wall. A later bath or shower left the switchgear inside the new bathroom.
- The airing cupboard opens beside the bathThe cylinder cupboard holds the fuse board. A door that opens into the bathroom puts that board in a room with a bath or shower.
- An old board was put in a bathroom cupboardInstallers fixed rewirable fuse boards in a bathroom cupboard. Those boards also lack an RCD. An RCD is a safety switch that cuts power when current leaks to earth.
- Steam condenses on the enclosureShowers fill the room with water vapour. The vapour cools on the fuse board cover and leaves rust, white deposits and damp at the cable entries.
- Height above the bath changes nothingA consumer unit high on the wall is still switchgear in the bathroom. A shaver supply unit is allowed in that room. A fuse board is not.
What can I check on a bathroom fuse box?
Look to see whether the fuse box shares the room with the bath or shower. Look only at the closed cover. The screws stay in and the cables stay untouched.
- Whether the box is inside the bathroomLook from the doorway. The fuse box is in the bathroom if it sits in the same room as the bath or shower. A high fixing or a cupboard does not change that.
- Rust, damp marks or a white filmCheck the outside of the cover for rust, green staining or a white film. Those marks show moisture has settled on the enclosure. Leave the cover shut.
- Heat, a buzz or a burning smellA warm cover, a buzz or a burning smell means a joint inside is failing. Use a breaker handle on the front only if that circuit must be off. Stay clear of the cover screws.
- Which way the cupboard door swingsOpen the cupboard door, not the fuse board cover. A door that swings into the bathroom puts the board in that room. A door onto a landing leaves the board outside the bathroom.
When should I book to move a bathroom fuse box?
Book Now if the fuse box is in the room with the bath or shower. Book Now if the cover is damp, rusty, hot or smelling of burning.
- The consumer unit is in the bathroomThe board is on a bathroom wall or in a cupboard that opens into that room. The board has to move outside the room. Moisture from the shower keeps reaching it while it stays.
- The cover shows heat or burningHeat, a buzz or a burning smell at the bathroom board means a connection is failing. Leave the cover on. Book Now so the unit can be isolated and moved.
- A new bathroom would close in the boardNew tiles, a bath panel or a cupboard can bury the fuse board in the same room. Move the consumer unit before that work closes around it.
- An EICR names the bathroom boardAn Electrical Installation Condition Report, an EICR, records switchgear in a bathroom when the inspection finds it there. Fuse board replacement takes that board out and retests the circuits.
What happens on the visit to move the fuse box?
We move the fuse board out of the bathroom on this visit. The new consumer unit is fitted outside the room. The supply stays off until the tests are finished.
- The new spot and the written priceWe view the bathroom board and a dry wall outside that room, such as a hall cupboard or landing. Earthing is the path that carries a fault away. Bonding joins metal pipes to that earth. We check both before any price is written. We also check that the supply can carry the load.
- Isolation and the new consumer unitWe isolate the incoming supply and remove the old board from the bathroom. The new consumer unit is fixed outside that room. Brands we fit include Hager, Wylex, Contactum, BG Electrical and MK Electric. Each circuit lands on a breaker with RCD or RCBO protection. An RCBO combines a breaker and an RCD for one circuit.
- Cables reconnected and markedWe reconnect each existing circuit at the new board. We mark each way so the breakers read clearly. The old bathroom position is left without a live fuse board.
- Tests and the certificateWe run insulation, continuity and RCD or RCBO tests before the supply is restored. The electrical certificate is issued for the fuse board replacement. Notification goes through our NAPIT registration. A circuit that fails its test stays switched off.
What does moving a bathroom fuse box cost?
The price covers removing the bathroom fuse board, fitting the new consumer unit outside that room, reconnecting the existing circuits and testing them. A longer run of cable to the new position changes the price. A larger board, a metal enclosure or a circuit that fails testing changes it as well. The written price comes before the supply is isolated.
From £450
Included when agreed
- Isolation of the incoming supply and removal of the existing fuse board
- Supply and fitting of a new consumer unit with RCD or RCBO protection to suit the circuits
- Reconnection of existing circuits and labelling of each way
- Dead and live tests on the circuits that feed from the new board
- An electrical certificate and notification through NAPIT where the work requires it
Not included automatically
- Rewiring damaged cables found in walls, lofts or under floors
- New sockets, lights, showers or chargers that need extra circuits
- Making good plaster, paint or kitchen units around the cupboard
Ways to pay


- Pay by bank
- Bank transfer
- The base price is a move to a nearby dry cupboard with the existing circuits.
- More cable, extra ways or a metal enclosure adds labour to the job.
- A damaged circuit found during testing is priced separately from the board move.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs a fuse box in the bathroom legal?
No. A consumer unit is switchgear, and that equipment is not permitted in a room containing a bath or shower. We move the board outside the room and test the circuits.
Where will you put the new fuse board?
We fit the new consumer unit on a dry wall outside the bathroom, such as a hall cupboard or the landing. The circuits have to reach that spot for reconnection. We write the price for that position before isolation.
Do I get paperwork when the bathroom board is moved?
Yes. You receive the electrical certificate for the consumer unit replacement. The job is notified through our NAPIT registration. A full EICR is a separate inspection of the rest of the installation.
Will my power be off while the board is moved?
Yes. We isolate the supply before the old board comes off. The power returns after the new consumer unit is tested.
Is a fuse box allowed if it is outside the zones?
No. Zones are the areas next to the bath or shower. A consumer unit is not allowed anywhere in that room, including a wall outside those zones. We fit the new board beyond the bathroom door.
Related problems
- Old fuse box: do I need to upgrade?An old fuse box needs an upgrade when it still uses fuse wire or has no residual current protection.
- Signs your fuse box needs upgradingA fuse box needs upgrading when it has fuse wire, no RCD, no spare ways, or a hot scorched cover.
- Still got rewirable fuses?A rewirable fuse box relies on fuse wire and has no residual current device, so the board is replaced and every circuit is tested.
- Unsatisfactory EICR: what happens next?An unsatisfactory EICR means a C1, a C2 or further investigation needs remedial work, and Lighting Electrical writes a price for those repairs.
- Aluminium wiring in the houseAluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
Sources
- BS 7671: IET Wiring Regulations (18th Edition)
- Electrical Safety First: Best Practice Guides
- Building work, replacements and repairs to your home
Updated 16 November 2026