Are sockets in skirting boards illegal?
No, sockets set low in the skirting board are not illegal, and Lighting Electrical tests the circuit behind them with an EICR to show whether they can stay.
Calls answered 24/7
- 10 years trading
- Local to Peterborough
Not sure? We'll check for you.
Why are there sockets in skirting boards?
Low sockets come from how homes were wired decades ago, when fewer appliances needed power and the skirting board was a handy place to fit one.
- Wiring from a much earlier eraA house wired long ago and never rewired often keeps its original low sockets, along with the cable and fuse box that were fitted with them.
- Circuits added to over the yearsAs households bought more appliances, extra sockets were often joined onto an existing circuit, so one cable may now feed more than it was planned for.
- No RCD on the circuitAn RCD (residual current device) is a switch that cuts the power in a fraction of a second if current leaks to earth. Older fuse boxes often have none.
- Cable rising from under the floorThe cable often comes up from beneath the floorboards straight to the socket box, with little covering it if the board or wall is disturbed.
What can I check safely myself?
Look and listen only. Leave every faceplate and the cover of the fuse box on, and do not unscrew, open or test anything.
- Look at each socket faceCracks, brown or black marks, a loose fit in the wall or a plug that falls out are all signs the socket is worn. Stop using any socket that shows them.
- Feel and listenA faceplate that is warm to the touch, or a socket that crackles or buzzes, needs an electrician soon. Switch off whatever is plugged into it.
- Look at the fuse box from outsideNote whether it has old fuse wire holders or modern switches. If one switch has a test button, press it once. It should flick off. Then switch it back on.
When should I book an electrician?
Book an inspection when the sockets are low and nobody has tested the wiring recently. Book sooner if anything looks or feels wrong.
- Low sockets and no recent EICRAn EICR is an electrical installation condition report, a written record of the state of the wiring. Without a recent one, the age of the circuits is a guess.
- Damaged, hot or scorched socketsBurn marks, cracks or a warm faceplate mean book now and keep that socket switched off in the meantime.
- An old fuse boxRewirable fuses, or a box with no RCD and no test button, point to an installation that has not been brought up to date.
- You are buying or letting the propertyLow sockets are a prompt to find out what the wiring is like before you commit, or before a tenant moves in.
What happens on the visit?
The visit is an inspection and test of the circuits behind the low sockets, followed by a written report and a clear choice of next steps.
- Test the circuits feeding the low socketsWe check earth continuity, which confirms the earth path is unbroken, and insulation resistance, which shows whether the cable insulation is still holding.
- Check RCD protectionWe see whether the circuit has an RCD and whether it trips when tested. Circuits that predate RCDs usually show up here.
- Look at the cable and fittingsWherever the cable can be seen, we note its type and condition, and we check the socket boxes and connections for wear or heat damage.
- Report and optionsThe EICR records anything unsatisfactory with a code. You then get priced options: leave the sockets, replace the circuit, or rewire part of the house and fit the sockets higher.
What does it cost to have low sockets checked or moved?
The price covers inspecting and testing the circuits that feed the low sockets and writing up the EICR. Any repair, replacement circuit or socket move is priced afterwards, from what the tests find.
From £150
Included in the inspection
- Visual check of the consumer unit, cabling, sockets, switches and fixed lighting
- Dead and live tests on the circuits, including earth continuity and insulation resistance
- Classification of each observation as C1, C2, C3 or FI on the report
- A written EICR for the property, signed by us
- A short talk through the findings before we leave
Not included automatically
- Repair of faults found during the test
- PAT testing of plug-in appliances
- A new consumer unit or a rewire
Ways to pay


- Pay by bank
- Bank transfer
- Moving a socket up the wall costs less when the existing cable is sound enough to extend, and more when the circuit has to be replaced.
- A circuit with no RCD protection and worn cable is usually priced as a replacement, because moving the socket alone would leave the problem in place.
EICR near you
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 63
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowAre sockets in skirting boards illegal?
No. Nothing in law forces you to remove them. Their position is a clue that the wiring behind them may be old, so the circuit is what gets tested.
Will low sockets fail an EICR?
Height alone does not fail one. The report records the condition of the wiring and its protection, and gives a code to anything that is not satisfactory.
Do sockets in a home need RCD protection?
Current wiring rules, BS 7671, call for RCD protection on ordinary sockets in a home. Older circuits often predate that, and the EICR shows which ones lack it.
Can my low sockets be moved higher up the wall?
Yes. The circuit is tested first. Sound cable can be extended to the new height. Worn cable is replaced at the same time, so the new socket sits on a circuit that is fit to carry it.
Related problems
- Aluminium wiring in the houseAluminium cable overheats at loose joints. We test it, write the electrical installation condition report, and price any copper replacement separately.
- Buying a house with old electricsAn EICR sets out the condition of old electrics before you buy, circuit by circuit.
- EICR C2 Meaning: Potentially Dangerous, Fix It UrgentlyA C2 is a fault that turns into a shock or fire risk after a second fault, and one C2 fails the whole EICR.
- House not up to electrical regulationsAn EICR names the parts of the fixed wiring that fall short of the current rules, and repairs are priced afterwards.
- How to tell if a house needs rewiringThe house needs rewiring when an EICR shows the cables or the fuse board cannot be made safe by repairing one circuit.
- Is my metal fuse box safe?A metal cover does not make a fuse box safe. The devices, earthing and cables settle that, and an EICR records the result.
Sources
- Electrical Safety First: RCDs explained (signs of old sockets)
- Electrical Safety First: older and vulnerable people (sockets on skirting boards)
- Electrical Safety First: Wiring Regulations Help, new and rewired installations
Updated 27 November 2026