House not up to electrical regulations

A house is not up to electrical regulations when its fixed wiring would fail an Electrical Installation Condition Report. Lighting Electrical in Peterborough tests that wiring and issues the EICR.

Calls answered 24/7

  • 10 years trading

Why is a house not up to electrical regulations?

A house falls short when the fixed wiring would not meet BS 7671, the IET Wiring Regulations. An EICR records each failed item. The age of the building does not settle the result on its own.

  • A consumer unit without RCD protectionA consumer unit is the board that holds the breakers for the fixed wiring. An RCD is a switch that cuts power when current leaks to earth. Socket circuits with no RCD protection fall short of the current rules where those sockets can supply equipment outside, and the EICR records that gap.
  • A lighting circuit with too many additionsA lighting circuit is the cable run that feeds the lights from one breaker. Adding many extra lights on that same cable can overload it or leave joints the wiring rules do not allow. The inspection records the circuit as it is found.
  • Earthing or bonding that is missingEarthing is the path that carries fault current so a breaker can open. Bonding is the link that joins metal pipes and other exposed metalwork to that earth. Missing or loose earthing or bonding means the installation is not up to the wiring rules.
  • Extra load with no spare capacitySpare capacity means the supply and the circuit can carry another load. Extra sockets, a longer kitchen run or an electric shower added without that room on the supply can overload the cable or the main switch. We check that the supply can carry the load before any repair price is written.
  • Notifiable work with no certificatePart P of the Building Regulations sets the electrical safety rules for dwellings. A new circuit, a replacement consumer unit, or new work in a room with a bath or shower needs a certificate. The EICR records that work when the certificate is missing.

What can you check safely around the house?

You can look at the closed consumer unit, the socket faces and any bonding clamp in sight. Keep every cover on. Keep your hands off cables, pipes and the inside of any appliance.

  • The closed consumer unitRead the front with the cover shut. Rewirable fuse carriers, no button for an RCD test, or a breaker sitting down all show that the installation needs an EICR. Leave the board alone if it is warm, buzzing or smelling of burning.
  • Socket faces and switch facesLook for brown marks, cracks, round pin holes or a faceplate that feels warm. Those signs are on the outside of the socket or switch. Leave every screw in place.
  • The RCD button on the frontThe button marked T sits on the RCD, the switch that cuts power when current leaks to earth. Press it once while the consumer unit is cool and quiet. If the power stays on, or does not return when you reset the switch, leave the consumer unit alone.
  • Bonding clamps you can seeA bonding clamp is the metal clip that links a pipe to the earth cable, often with green and yellow sleeving. Look for that clamp on the metal water pipe near the consumer unit. A missing clamp is a gap the inspection will record, and the clamp stays untouched.

When should you book an electrical regulations inspection?

Book Now for an EICR in Peterborough when a landlord, a buyer or an insurer needs a current report, or when the safe checks show the installation falls short.

  • A private rented home needs a current EICRPrivate rented homes in England need a current EICR at intervals of five years. They also need one when a new tenancy starts after the last report has expired. We inspect the dwelling and issue the report for the tenancy file.
  • A buyer, lender or insurer has askedSolicitors and lenders often ask for an electrical safety report before exchange. An insurer can ask for the same record of the fixed wiring. The EICR gives that dated result.
  • Heat, noise or a test button that does nothingIf the consumer unit is warm, buzzing or smelling of burning, switch off that circuit with the handle on the front and leave the cover on. If the RCD button does not cut the power, leave the board alone. Either sign is a reason to Book Now.

What happens on the EICR visit?

We inspect and test the fixed wiring, then complete the EICR. Parts of the test need the supply switched off. Any repair is priced after the report and is separate from this visit.

  • Confirm the installation and walk roundWe look at the consumer unit, the sockets, the switches and the fixed lights, and we note alterations you point out. Trips, warm fittings and earlier additions help the inspection. We unscrew nothing until our tester shows there is no voltage on that circuit.
  • Test each circuit with the supply offWe switch off the supply and test one circuit at a time. The dead tests check that the earth path is continuous and that the insulation between conductors is sound. We put the supply back one circuit at a time and then carry out the live tests.
  • Mark each finding and finish the EICREach observation is marked C1, C2, C3 or FI, and FI means further investigation. We isolate a C1 danger before we leave. We talk through any C1 or C2 item and hand you the written EICR before the visit ends.
  • A repair price only if the report failsAn unsatisfactory report is followed by a written repair price, which you can accept with us or take elsewhere. That price is not inside the inspection. Before we write it we check the earthing, the bonding and whether the supply can carry any further load.

What does an electrical regulations inspection cost?

The EICR price covers the inspection of the fixed wiring and the written electrical safety report. It changes with how many circuits we test, whether an outbuilding is included, and whether the premises are a house or a commercial unit. Remedial work, a new consumer unit and a rewire are priced on their own after the report.

From £150

Included in the inspection

  • Visual check of the consumer unit, cabling, sockets, switches and fixed lighting
  • Dead and live tests on the circuits, including earth continuity and insulation resistance
  • Classification of each observation as C1, C2, C3 or FI on the report
  • A written EICR for the property, signed by us
  • A short talk through the findings before we leave

Not included automatically

  • Repair of faults found during the test
  • PAT testing of plug-in appliances
  • A new consumer unit or a rewire

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • A small flat with few circuits takes less time than a large house or a shop with many circuits.
  • Parts from Hager, Wylex, Contactum, BG Electrical or MK Electric are priced only on a later repair.
  • We complete the report under our NAPIT registration and include the paperwork that inspection requires.

View the EICR cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about electrical regulations in a house

Still have a question?

Will an unsatisfactory EICR mean the house needs a rewire?

No. Each item is marked C1, C2, C3 or FI, and a rewire follows only when the circuits cannot stay in service. A failed consumer unit, a bonding link or one damaged circuit is priced on its own after the report.

Who needs to be present while the power is off?

A person who can let us into the dwelling needs to stay, because the supply is off during the tests. A tenant may stay when the landlord has arranged the visit. Each circuit is put back on when its own tests are finished.

How is an EICR different from a minor works certificate?

An EICR is the inspection of the whole fixed installation and it carries an overall result. A minor works certificate records one change to an existing circuit after that repair is finished. This visit produces the EICR, and a later repair that changes a circuit gets the minor works certificate under our NAPIT registration.

Can the failed items be repaired during the inspection?

No. This visit is the inspection and the written EICR. We isolate a C1 danger before we leave. The repair waits for a separate written price.

Will a newer house pass because it is newer?

No. A newer house can still fall short of the wiring rules. We check the earthing, the bonding and the spare capacity on the supply, and missing protection or a poor later addition can make the report unsatisfactory.