Electric radiator not heating
An electric radiator that stays cold has either a dead supply or a failed heater. Lighting Electrical in Peterborough tests the circuit, the wall switch and the controls, then names the part that failed.
Calls answered 24/7
- 10 years trading
Why is an electric radiator not heating?
An electric radiator stays cold because the supply has opened, the wall controls are off, or the heater itself has failed. Other rooms can stay powered when the heater has its own breaker.
- The timer or thermostat is holding it offA timer sets the hours the heater may run. A thermostat is the dial that calls for heat. If the timer is in an off period, or the dial sits below the room temperature, the element never switches on and the panel stays cold.
- The wall switch or its fuse is openA fixed heater takes power through an isolator, the wall switch that cuts its supply, or a fused connection unit, a switch that holds a small fuse. If that switch is off or the fuse has opened, the radiator has no power while the rest of the room stays on.
- The heater breaker has trippedA breaker is the switch in the fuse board that guards one circuit. It opens on too much current, or on a leak to earth, the safety path for fault current. The radiator goes cold. Lights on another breaker stay on.
- The heater control or element has failedInside the radiator a thermostat, a cut out or the heating element can fail. A cut out is a safety switch that opens if the heater gets too hot. The wall supply can still be live while the panel stays cold.
- A joint on the heater circuit is looseHeat at a terminal loosens the screw over time. The radiator flickers, smells warm, or dies while the breaker stays up. That joint sits in the switch or along the cable and needs a test with the circuit off.
What can I check on a cold electric radiator?
You can read the heater controls, the wall switch and the fuse board with every cover left on. You leave the radiator casing shut and you do not touch the wiring.
- The thermostat and the timerSet the thermostat above the room temperature and put the timer on a constant period. A radiator that stays cold is not waiting for its programme. Return the controls to the old setting if you are unsure.
- The wall switch for the heaterFind the isolator or fused connection unit beside the radiator. If the switch is off, switch it on once. If it has a fuse carrier, look only to see that the carrier is seated. Leave the switch screws in place.
- The breaker with the board cover shutLook through the closed fuse board cover for a switch sitting down. If the board is cool, quiet and free of a burning smell, raise that switch once. If it drops straight away, leave it off.
- Whether one heater or every heater is coldNote which electric radiators on that circuit are cold. One cold heater points to that heater or its wall switch. Every heater cold points to the breaker or the cable leaving the fuse board.
When should I book for a cold electric radiator?
Book Now when the controls are calling for heat and the radiator stays cold, or when a switch, a fuse or the heater smells hot. A timer that is simply in an off period can wait.
- The heater stays cold on a live switchThe timer is calling for heat, the wall switch is on, and the panel stays cold. The fault is in the heater controls, the element or a joint. Switching the heater again will not warm the room.
- The breaker will not stay upYou raised the heater switch once and it opened again. The fault is still on that circuit. Another reset heats the breaker and the cable. Leave the switch off.
- Heat, a buzz or a burning smellA warm wall switch, a buzz or a burning smell means a joint is failing. Use the breaker handle to switch that circuit off. Keep your hands off the switch screws and the radiator casing.
What happens on a visit for a cold electric radiator?
We test the heater circuit with it switched off and name the failed part before anything is changed. The repair starts after you accept it.
- What went cold and which switch is offWe ask when the radiator went cold and whether other heaters on that circuit still warm up. We read the isolator, the fused connection unit and the breaker with you. No cover comes off until a tester shows the circuit is dead.
- Tests that separate the supply from the heaterWith the circuit off we measure whether the cable is broken, shorted or leaking to earth. We then test at the wall switch and at the heater terminals. Those readings separate a failed breaker, a failed switch, a damaged cable and a dead element.
- Earthing and spare capacity before a further priceWe tell you the failed part before a repair. Earthing, the path that lets fault current open a breaker, is checked on the visit. Bonding, the link from metal pipes to the fuse board, is checked too. We also see whether the supply can carry the heater load.
- The repair and the paperworkOnce you accept the repair we fit the failed switch, fuse, cable or connection and test the circuit again. A minor works certificate records that change and our NAPIT registration. A radiator whose element has failed stays disconnected. A circuit that fails the test stays off at its breaker.
What does a cold radiator fault visit cost?
The hourly price for Electrical Fault Finding & Repair pays for measuring the cold radiator circuit, telling you what failed, and beginning that repair after you accept it. Time rises if several switches on one heater run need testing. A part, a minor works certificate or a fuse board change is added only when the tests call for it. Emergency electrician work is priced as its own job.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A single cold heater with a failed fuse takes less time than tracing a fault shared by several radiators on one circuit.
- A switch, breaker or cable from Hager, Wylex, Contactum, BG Electrical or MK Electric is fitted only when the tests show that part has failed.
- Fuse board replacement is a separate written job when the tests show the heater breaker or the board has failed.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs the radiator broken or is the supply dead?
We separate those two on the visit. A live supply with an open element or thermostat means the heater itself has failed. A dead supply means the breaker, the wall switch or the cable is the failed part.
Should I reset the heater breaker more than once?
One reset is enough, and only when the fuse board is cool and quiet. If the switch opens again, leave it off. Repeated resets heat the terminals while the fault is still there.
Will you take the radiator apart?
We open the wall switch or the connection only after the circuit is proved dead and the tests point there. A sound heater stays shut. If the element or the internal control has failed, we say so and leave the supply switched off.
Do I get paperwork after the heater circuit is repaired?
Where the repair changes the heater circuit, we issue a minor works certificate for that job. The certificate lists the test results and our NAPIT registration. An EICR, the Electrical Installation Condition Report, is a different inspection of the whole installation.
Can you connect a replacement electric heater?
Yes. Appliance and heating connections cover a new fixed heater once the circuit tests sound. On a cold radiator we still find the failed part first. A new heater is priced only if you ask for one after that.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
Sources
- Energy Saving Trust: Heating Your Home
- Electrical Safety First: Safety Guidance
- HSE: Electrical Safety at Work
Updated 16 November 2026