Electric shower not working

No power at an electric shower means its own circuit from the fuse board has opened. In Peterborough, Lighting Electrical tests the breaker, the pull switch and the shower cable and tells you which has failed.

Calls answered 24/7

  • 10 years trading

Why has my electric shower got no power?

An electric shower loses power when its own circuit opens at the fuse board, the pull switch or inside the unit. Other lights and sockets stay on because they use different breakers.

  • The shower breaker has openedThe shower sits on its own breaker in the fuse board. That breaker opens when the circuit draws too much current. The shower then goes dead, and lights and sockets on other breakers stay on.
  • Current leaking to earthAn RCD compares current leaving a circuit with current returning and opens if some leaks away. Water in the shower or a damaged heater causes that leak. The shower RCD, or an RCBO that guards this circuit alone, then opens and the shower loses power.
  • A failed pull switchThe pull switch above the shower is a double pole isolator. It breaks both live conductors feeding the unit. Burnt contacts or a loose terminal in that switch leave the shower dead while the breaker stays up.
  • A cut out inside the showerA thermal cut out inside the unit opens when the heater runs too hot. A failed heater or a stuck flow switch stops the spray in the same way. The case stays closed until the circuit has been tested.
  • A break in the shower cableThe shower cable runs from the fuse board to the pull switch and then to the unit. A loose terminal or a broken conductor opens that run. The shower stays dead until that break is found.

What can I check safely on a dead electric shower?

You can read the fuse board, try the pull switch and see whether the rest of the house still has power. The shower case stays shut and no wire is touched.

  • The shower breaker with the cover onLeave the fuse board cover shut. Find the breaker named for the shower and see if it sits down. If the board is cool and you smell nothing burning, lift that breaker once. If it opens again at once, leave it off.
  • The pull switch above the showerPull the cord so the switch is on. A click with no spray and no light on the shower means power is not reaching the unit. Stop after that single try. Leave the switch screws in place.
  • Lights and sockets in other roomsTurn on a light and try a socket away from the bathroom. Power in those rooms means only the shower circuit has opened. A dark house means a wider loss than the shower alone.
  • Water, heat or a burning smellLook at the outside of the shower and the pull switch. Drips, a warm switch or a burning smell mean that circuit should stay off. Do not wipe live parts and do not take the shower front off.

When should I book for an electric shower with no power?

Book Now after a single reset fails to hold, or when the pull switch is hot or wet. A shower that only needs its pull switch turned on is a different matter.

  • The shower breaker will not holdYou lift the shower breaker once and it opens again. The fault is still in the cable, the pull switch or the unit. Leave that breaker off so the terminals do not heat.
  • Heat, a buzz or a burning smellA warm pull switch, a buzz or a burning smell means a joint is arcing. Arcing is a spark jumping across a loose terminal. Leave the shower breaker off and keep the case shut.
  • Water leaving the shower caseWater from the case can reach live parts and hold a safety switch open. Keep the shower breaker off. Keep your hands off the front cover and the pull switch screws.

What happens on a visit for a dead electric shower?

We test the shower circuit from the fuse board and name the failed part before any switch, cable or unit is changed. Any repair starts after you accept it.

  • What stopped at the showerWe ask when the shower died and whether the breaker dropped. We ask if you saw water or smelt burning. We look at the fuse board and the pull switch with you. Screws stay in until our tester shows the shower circuit is dead.
  • Tests with the shower circuit offWe switch off the shower breaker and test the cable while it is dead. The readings show a short, a break or a leak to earth. They separate the breaker, the pull switch, the cable and the unit.
  • The failed part, said before a priceWe tell you which part failed before anything is changed. We measure the earth path that lets a breaker open, and the bonds between metal pipes and the fuse board. We measure whether the supply can feed this shower before any further price is written.
  • The repair and the certificateWe repair the failed breaker, pull switch or cable after you accept that work. We test the shower circuit again. A change to the circuit is written up on a minor works certificate carrying our NAPIT registration. A failed shower unit is priced as Electric shower installation, and an unsafe circuit is left switched off.

What does an electric shower fault visit cost?

Electrical Fault Finding & Repair is charged by the hour for a dead shower. The price covers the tests, the spoken diagnosis and the repair after you accept it. A longer test, a replacement part or a minor works certificate changes the price. Electric shower installation is a separate price when the unit has failed. Emergency electrician attendance is a separate price as well.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • A concealed cable between the fuse board and the shower takes longer to test than a fault at the pull switch.
  • We fit a breaker, a pull switch or cable only after the tests show that part has failed.
  • Fuse board replacement is a separate written price when the shower breaker or the board has failed.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

What else do people ask about a dead electric shower?

Still have a question?

Should I reset the shower breaker more than once?

One reset is enough, and only while the fuse board is cool and quiet. If the breaker opens again, leave it off. Further resets heat the shower cable and the pull switch.

Will you replace the shower before you find the fault?

No. We test the breaker, the pull switch and the cable and name the failed part first. A sound unit stays on the wall. Electric shower installation starts only when the tests show the unit has failed and you accept that job.

Do the lights and sockets stay on while the shower is tested?

Yes. We open only the shower breaker for the tests. Lights and sockets on other breakers stay in use. That breaker is put back on only when the tests show the circuit can be left live.

What paperwork follows a repair to the shower circuit?

Where we change the pull switch, the cable or the breaker, we write a minor works certificate. It records the tests for that job and our NAPIT registration. If nothing is changed, we leave you the readings and the name of the failed part.

My shower is a Mira. Does that change the visit?

We still test the circuit before the unit is condemned. Mira is a brand we install, so a failed Mira unit can be replaced as Electric shower installation. The visit still starts with the breaker, the pull switch and the cable.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)