Exposed electrical wires in the house

Exposed wires in the house leave copper open where a person can touch it. Lighting Electrical in Peterborough isolates that circuit and tests the cable before any repair.

Calls answered 24/7

  • 10 years trading

Why are wires exposed in the house?

Wires show bare copper when the sheath or the coloured core insulation has split, been cut, or come off a joint.

  • Old insulation has crackedOlder lighting cable used rubber or fabric around the copper. That covering dries, cracks and falls away in a loft or above a ceiling. We test the cable because the age of the house does not tell us it is sound.
  • A cut or a nail through the sheathA picture fixing, a floorboard nail or a saw can slice the sheath in one place. The copper shows at the cut. The cable on either side can still look whole.
  • A joint left out of an enclosureA joint connects two or more cables. Conductors left outside a closed box stay bare. The same thing happens when a back box is too shallow and the cores push past the socket or the switch.
  • Worn flex on a light or an applianceA pendant is a light hung on flexible cord. Rubbing at the ceiling rose wears that cord through. Chewing in a loft does the same. The coloured cores then hang where a hand can meet them.
  • Heat or water has opened the sheathHeat from a hot lamp, or water running along a cable, cracks the plastic sheath. Sun on an outdoor cable does the same over time. Once the sheath has split, the copper is open.

What can I check without touching exposed wires?

You can look from a safe distance and use the fuse board only when your hand stays clear of the bare copper.

  • Which room and which fittingNote the room and the fitting where the copper shows. A ceiling rose, a socket, a loft cable and a pendant flex are different repairs. Stand where nothing you wear can brush the copper.
  • The breaker, if you can reach it safelyA breaker is the switch on the fuse board that guards one circuit. If the board is in another room and the cover is closed, switch off the breaker for that room and leave it off. If the bare copper is next to the board, stay back and Book Now.
  • Whether the cable still looks liveLights still on along that cable, a buzz, or a smell of burning mean you treat the copper as live. Do not cover it with tape. Do not push the cores back into the wall or the rose.
  • Who and what is near the cableKeep children and pets out of the room. Keep water and metal tools away from the copper. Leave furniture where it is if moving it would touch the wire.

When should I book for exposed wires?

Book Now as soon as copper is visible, including when the lights still work and the fuse board is cool and quiet.

  • You can see copperVisible copper on a cable, in a rose or behind a loose socket is enough. You do not need a burning smell or a dead circuit first. Switch that circuit off only if you can do it without touching the copper, then Book Now.
  • Someone felt a shock, or the spot is hotA shock, browning or heat at the break means current has already left the cable. Leave the circuit off. Keep people away from the spot until the circuit is isolated.
  • The damage is in a loft, a floor or outdoorsA chewed length, a nicked sheath or a split outdoor cable can stay live out of sight. Do not cover the copper with a board, a cloth or tape. Book Now so the circuit can be isolated and tested.

What happens on a visit for exposed wires?

We make the damaged cable dead, test it, and tell you the repair before any new part is fitted.

  • Isolate the circuit with the bare copperWe ask where the copper is and whether a breaker is already off. We prove the cable is dead with a tester before we touch it. Circuits that test sound stay on.
  • Test the damaged cableWith the circuit dead, a continuity test shows whether the copper still runs end to end. An insulation test shows whether current leaks between cores or to earth. Earth is the path that lets fault current flow away from a person. Those readings separate one nicked spot from a longer failed run.
  • Repair only the part that failedWe tell you the result before a part is changed. A sound joint goes into a closed enclosure. A failed length is replaced after you say yes. A fitting from MK Electric, BG Electrical or Varilight goes on only when that fitting is damaged. An open or failed consumer unit from Hager, Wylex or Contactum is priced as Fuse board replacement, not as this repair.
  • Certificate, earthing and the next priceIf we alter the circuit we write a minor works certificate with our NAPIT registration on it. Before a further price we check earthing, bonding and whether the supply can feed another load. Bonding joins metal pipes and other metalwork to the earth at the fuse board.

What does repairing exposed wires cost?

The price follows the time taken to isolate the cable, test it and complete the repair you have accepted. That price includes the diagnosis we give you on the visit. Replacing a short damaged end takes less time than a longer run through a loft or under a floor. A replacement fitting, a minor works certificate, or Fuse board replacement written as its own job, changes the price.

From £90 an hour

Included in the call-out

  • Attendance at the property in Peterborough or a nearby Essex town
  • Isolation of the failed circuit, fitting or board
  • Fault finding on the circuit that has gone down
  • Temporary making safe so the rest of the installation can be used where that is possible
  • A written note of what failed and what work should follow

Not included automatically

  • A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
  • Parts we do not carry in the van, which we price in writing before we fit them
  • Work on another trade such as gas, plumbing or structural fabric

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • We fit a socket, a switch, a ceiling rose or a length of cable only when the tests show that part has failed.
  • Fuse board replacement has its own written price when the consumer unit is open or has failed.
  • Emergency electrician is a separate charge from Electrical Fault Finding & Repair.

View the emergency call-out cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about exposed wires

Still have a question?

Can I wrap tape around the bare copper?

No. Tape only hides the copper and leaves the insulation missing. Switch the circuit off if you can do that without touching the cores. Book Now and keep clear of the cable.

Will the repair be finished on the same visit?

We name the failed length, joint or fitting before anything new is fitted. That repair goes ahead on the visit after you say yes to it. Fuse board replacement and House Rewiring are priced as their own jobs.

What certificate do I get?

A minor works certificate is issued when the repair changes the circuit. It lists the test results for that job and shows our NAPIT registration. An EICR inspects the whole installation and is booked separately.

Should the whole circuit be rewired?

Not from the look of one bare spot. The tests show whether the fault is a single cut, a joint, or insulation that has failed along the run. House Rewiring is quoted only when those tests show the rest of the circuit insulation has failed.

What if I already had a shock from the wire?

Stay away from the cable. If that breaker is already off, leave it off. We isolate and test the circuit that gave the shock before we repair it, and we leave healthy circuits switched on.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (1)