Garden lights not working
Garden lights that stay off while the house stays lit mean the outdoor lighting circuit or a garden fitting has failed. Lighting Electrical in Peterborough names the part that failed.
Calls answered 24/7
- 10 years trading
Why have the garden lights stopped working?
Garden lights stop because the outdoor circuit has opened, or a lantern, sensor, timer or cable joint on that circuit has failed. House lights stay on when they use a different breaker.
- The outdoor breaker or RCD has openedA breaker is the switch in the fuse board that guards one circuit. An RCD switches that circuit off when current leaks to earth. Earth is the return path for fault current. Rain in a lantern opens the outdoor breaker or the RCD. A damaged outdoor cable does the same. Lights on other breakers stay on.
- Water inside a lantern or a jointRain and dew enter a wall lantern, a ground light or a joint in the garden cable. Water across the contacts leaks to earth. Water also blocks the connection to the lamp. That lantern goes dark. A large leak opens the RCD and every light on it goes dark.
- A sensor or a timer has stoppedA PIR is a sensor that switches a lantern on when someone moves nearby. A photocell switches lights when daylight fades. A timer switches them for set hours. A failed PIR or photocell leaves the lamp dark. A timer set to off does the same. The sensor is a separate part from the cable.
- A break in the garden cableThe garden cable is buried in the border or fixed along a wall. A crushed joint, a cut or a loose terminal opens that cable. Lanterns beyond the break go dark. Lanterns between the fuse board and the break stay lit.
- One lamp or one LED driver has failedA driver is the unit inside an LED lantern that powers the lamp. A failed lamp leaves that fitting dark. A failed driver does the same. The next lantern stays lit on its own lamp and driver.
What can I check safely on garden lights?
You can read the fuse board through the closed cover. You can try the garden switch and the timer. You can look at each lantern from the outside. You leave every fitting shut and every cable untouched.
- The outdoor switch on the fuse boardLeave the fuse board cover on. The outdoor lighting breaker sits down when that circuit has tripped. The RCD for that circuit sits down when current leaks to earth. Reset the switch once only when the board is cool, quiet and free of a burning smell. If it opens again at once, leave that switch down.
- The wall switch and the timerTurn the garden light switch on. Where a timer controls the lights, move it to the manual on setting. A stopped clock in the timer leaves the lanterns dark. The breaker stays up in that case. Leave the timer case shut.
- One lantern dark or every lantern darkWalk the garden and note which lights are out. One dark lantern beside lit ones points to that lamp or that sensor. Every garden light dark points to the breaker, the RCD, the timer or the first joint after the fuse board.
- Damage you can see with the fitting shutMist in a glass globe shows water inside the lantern. A cracked cover shows the same problem. A cable lying chewed on the soil is damaged. Do not unscrew the lantern. Stay clear of wet plastic and of any exposed copper.
When should I book for garden lights not working?
Book Now when the outdoor switch will not stay up, a lantern is hot or smells of burning, or the lights fail after rain. A single spent lamp in a cool dry fitting is a different job.
- The outdoor breaker will not holdThe switch is already on and the breaker still opens at once. The fault sits in the cable, a lantern or the protective device. Another reset heats the terminals. Leave the circuit off and Book Now.
- Heat, a buzz or a burning smellA warm lantern means a joint is failing. A buzz or brown marks mean the joint is arcing. Arcing is a spark across a loose connection. That spark chars the cable. Switch the circuit off at the breaker handle. Leave the lantern screws in place.
- The lights die after rainWater in a lantern or a buried joint leaks current to earth after wet weather. The RCD opens and the garden goes dark. With that circuit already off, wipe only the outside of a globe. Book Now before anyone uses the circuit again.
- A cut cable or only some lightsSome lanterns lit and others dark means the run is open at a joint. A cable cut by a spade is that same open circuit. Do not touch the copper. Leave the outdoor breaker off.
What happens on a garden light fault visit?
We isolate the outdoor lighting circuit at the fuse board. We name the failed lantern, sensor, joint or cable before anything is changed. House circuits that test sound stay on.
- Which lights died and which switch openedWe ask which lanterns are dark. We ask whether a sensor or a timer controls them. We ask when they last worked. We stand at the fuse board with you and note the switch that has opened. No cover comes off until a tester shows that circuit is dead.
- Tests along the outdoor circuitWe switch the outdoor circuit off before any test. A continuity test checks whether the copper still joins the fuse board to each lantern. An insulation test checks for leaking current between the conductors. It also checks for leaking current to earth. Those results separate a breaker, a sensor, a joint and a length of cable.
- The failed lantern, sensor or cable jointWe open only the fitting or the joint the tests have shown as failed. A sound lantern stays shut. On an outdoor enclosure we check the glands and the earth bar. A gland is the seal where armoured cable enters the box. Armoured cable has a metal layer under the sheath.
- The repair, the certificate and any further priceOnce you accept it, we repair the failed lantern, sensor, joint or cable. We test that circuit again. A minor works certificate follows when we alter the circuit. Our NAPIT registration is on that certificate. Before any further price we check earthing, bonding and spare capacity on the supply. Earthing is the fault path back to the fuse board. Bonding joins metal pipes to that earth.
What does a garden light fault visit cost?
Electrical Fault Finding & Repair is charged by the hour for this work. The price covers the tests on the outdoor lighting circuit. It covers the diagnosis we explain to you. It covers the repair once you accept it. Time at several lanterns or on a buried joint changes the price. A replacement part changes the price. A minor works certificate changes the price. Fuse board replacement is its own job. Emergency electrician attendance is its own job.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A single dark wall lantern takes less time to test than a row of lights with a break in buried cable.
- A lantern, sensor, breaker or length of cable is fitted only when the tests show that part has failed.
- Lighting installation is its own price for new garden lights.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWill the rest of the house stay on?
Yes. We switch off only the outdoor lighting circuit for the test. Indoor lights and other sound circuits stay on. The outdoor circuit is put back on after the repair only when it can be left live.
Will you change the lanterns before you know the fault?
No. We test the outdoor run first and name the failed lantern, sensor, joint or cable. Work on that part starts once you accept the repair. A lantern that tests sound stays in place.
Can you trace a fault in low voltage garden lights?
Yes. Low voltage garden lights use a transformer, which steps the supply down to the voltage the lamps need. We test the transformer, the cable after it and each lamp. A failed transformer is named before it is replaced.
Do I get paperwork after a garden light repair?
When we alter the outdoor circuit you receive a minor works certificate. The certificate lists the test results and our NAPIT registration. An Electrical Installation Condition Report, an EICR, is a separate full inspection arranged on its own.
Will a new fuse board bring the garden lights back?
The garden lights need a new fuse board only if the outdoor device in that board has failed the test. A wet lantern or a cut cable still leaves the lights dark. Any fuse board replacement is written up separately after the outdoor tests.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.