Why is my light switch hot to touch

A light switch that is hot to touch is overheating at the switch or on the lighting circuit. Lighting Electrical in Peterborough isolates that circuit and finds what is heating it.

Calls answered 24/7

  • 10 years trading

Why is a light switch hot to touch?

A light switch heats up when a joint, the switch or a dimmer is carrying current badly. That heat reaches the plate on the wall.

  • A loose terminal in the switchA terminal is the screw that clamps the cable inside the switch. A loose clamp leaves a small gap. Current jumps that gap. The metal then heats the plate. The lamp can still be lit while the plate is too hot to hold.
  • A dimmer on the wrong lampsA dimmer is a switch that varies how bright the lamps are. It has to match those lamps. LED lamps on a dimmer built for old filament lamps run hot in the plate. We fit a Varilight or MK Electric dimmer when tests show the old one has failed.
  • Too much load on one switchEvery switch is made for a limited load. Several spot lamps on one switch can pass that limit. A lighting circuit extended with extra fittings can do the same. The plate warms while the lamps are on. It cools when they go off.
  • A worn switch that sparks insideArcing is a spark across worn contacts inside the switch. Each use of the switch makes another spark. The spark chars the plastic. A crackle follows. The plate heats after the light has been on for a short time.
  • A hot joint in the lighting cableThe heat can start in a cable joint behind the plate. A poor joint raises resistance. Resistance turns current into heat. A breaker is the switch in the fuse board that protects one circuit. It can stay on because the current heats the joint without rising enough to open it.

What can I check on a hot light switch?

You can look, listen and switch the lamp off. You leave the switch screws in place. You leave the fuse board cover on.

  • Whether the plate cools with the lamp offSwitch the lamp off at the plate if you can still touch it. A plate that cools is heating only while the lamps are on. A plate that stays hot with the lamp off needs the lighting breaker off. Use the breaker handle only. Leave the fuse board cover on.
  • Brown marks, a smell or a crackleLook for brown marks or softened plastic on the plate. A burning smell means a joint is overheating. A crackle means arcing inside the switch. Keep your fingers off the screws. Leave that switch off.
  • Dimmer or plain switch, and the lamp countSee whether the plate is a dimmer or a plain switch. Count the lamps that plate controls. A dimmer on LED lamps points us to the dimmer first. Many spots on one plate point us to the load. The plate stays closed.
  • The lighting breaker through the coverRead the names on the breakers through the closed cover. Switch off the breaker named for the lights if the plate is too hot or you smell burning. Leave a breaker that opens straight away in the off position. Do not open the fuse board.

When should I book for a hot light switch?

Book Now when the plate is too hot to hold, when you smell burning, or when the plate stays hot with the lamp off.

  • The plate is too hot to holdA switch you cannot rest a hand on is past ordinary warmth. A dimmer can feel warm while it is working. Heat that hurts means the joint or the dimmer is failing. Leave that lighting circuit switched off.
  • Burning, brown marks or a crackleA smell of hot plastic, brown staining or a crackle is arcing at the terminals. Arcing can char the cable in the box behind the plate. Switch the lighting breaker off. Keep the plate untouched.
  • The plate stays hot with the lamp offA plate that stays hot after the lamp is off is not warming from the lamps alone. Current is still heating a joint. That lighting circuit stays off until we test it.
  • The lighting breaker will not stay onLeave the breaker off if it opens as soon as the lights are switched on. Another reset heats the same joint. Circuits that are still healthy on the fuse board can stay on.

What happens on a visit for a hot light switch?

We isolate the lighting circuit, test the hot switch and name the failed part before we change it. Healthy circuits stay on where the fuse board allows that.

  • Which plate is hot, then isolationWe ask which plate is hot and whether it is a dimmer. We ask if it cools after the lamp goes off. We switch off the lighting breaker. The plate stays on the wall until a tester confirms that circuit is off.
  • Tests on the switch and the cableWith the circuit off, we test the switch and the lighting cable. The results point to a loose terminal, a worn switch, a mismatched dimmer or a hot joint in the cable. We tell you which one it is before any part is changed.
  • Earthing, bonding and the lighting loadBefore any further price, we check the earthing, the bonding and whether the supply will carry the lighting load. Earthing is the path that lets fault current open a breaker. Bonding links metal pipes to the fuse board.
  • The new switch and the certificateWe fit the replacement when you want that repair done on the visit. We use MK Electric, Varilight or BG Electrical when the old switch or dimmer has failed. We test the lighting circuit once the new part is fitted. A minor works certificate records those tests and our NAPIT registration. The lighting breaker stays off if the circuit cannot go back on.

What does a hot light switch visit cost?

The emergency electrician price covers attendance, tests on the hot switch and its lighting circuit, and making that circuit safe to leave. The price changes when testing takes longer, when a switch or a dimmer is fitted, or when a minor works certificate is needed. Fuse board replacement is a separate price when the tests show the board has failed. Light switch or dimmer replacement is a separate price when that is the repair.

From £90 an hour

Included in the call-out

  • Attendance at the property in Peterborough or a nearby Essex town
  • Isolation of the failed circuit, fitting or board
  • Fault finding on the circuit that has gone down
  • Temporary making safe so the rest of the installation can be used where that is possible
  • A written note of what failed and what work should follow

Not included automatically

  • A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
  • Parts we do not carry in the van, which we price in writing before we fit them
  • Work on another trade such as gas, plumbing or structural fabric

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • Tracing heat from a joint in the lighting cable takes longer than finding one loose terminal in the switch.
  • An MK Electric, Varilight or BG Electrical switch or dimmer is fitted only when the tests show the existing one has failed.
  • Fuse board replacement carries its own price when the lighting breaker or the board has failed.

View the emergency call-out cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions on a hot light switch

Still have a question?

Is a warm dimmer a fault?

A dimmer often feels warm while the lamps are on. You should still be able to rest a hand on the plate. Heat you cannot hold, a smell, or a plate that stays hot with the lamps off is a fault. We test the dimmer and the lamps before we change it.

Can I keep using the light?

Leave the light off if the plate is hot, marked or smelling. Use the lighting breaker if the plate stays hot. Other circuits on a cool, quiet fuse board can stay in use. We switch off only the breaker that feeds the hot plate.

Will you replace the switch on the same visit?

We name the failed switch, dimmer or joint before we fit anything. We change that part on the visit when you want the repair done then. A sound switch stays on the wall. A new fuse board waits for its own price when the tests show the board has failed.

Do I get paperwork after the switch is changed?

Where we change the switch or the dimmer, we issue a minor works certificate. It lists the test results for that job and our NAPIT registration. If we only isolate the circuit, we write down the readings and the failed part. An EICR inspects the whole installation and is a separate job.

Why is the switch hot if the breaker has not tripped?

A hot switch can sit on a breaker that is still on. The current is enough to heat a loose joint. It is too low to open the breaker. Leave that lighting breaker off. We test the joint rather than waiting for the breaker to move.