Light won't turn off

A light that stays on means the switch, the sensor or a joint is still feeding the lamp. Lighting Electrical in Peterborough tests that lighting circuit and names the part that will not open.

Calls answered 24/7

  • 10 years trading

Why does a light stay on?

A light stays on when power still reaches the lamp after you set the switch to off. The feed is a closed switch, a stuck sensor, a failed dimmer or a joint that bypasses the switch.

  • Switch contacts welded shutA switch should open and cut power to the lamp. Arcing is a spark jumping across worn contacts. That spark welds the contacts together. The lamp then stays on in both positions of the switch.
  • Two way wires in the wrong terminalsTwo way switching uses two switches for one lamp, such as a switch in the hall and a switch on the landing. The strapper wires are the pair running between those switches. In the wrong terminals they keep feeding the lamp.
  • A dimmer that stays closedA dimmer is a switch that also sets how bright the lamp is. When the switch inside the dimmer fails closed, the lamp stays at full brightness and the knob no longer turns it off. We fit a Varilight dimmer only after the test shows the dimmer has failed.
  • A sensor holding a lantern onA PIR sensor turns a lantern on when it detects movement. A photocell turns a lantern off in daylight. When either device sticks closed the lantern stays lit. We test the sensor on a wall lantern before we change the lamp.
  • A joint past the switchIn a ceiling rose the permanent live loops on to the next light and a switch wire comes back from the switch. A joint that connects the lamp to the permanent live feeds the lamp all the time. We find that joint where a lighting circuit has been extended.

What can I check before booking?

You can check the switches, the dimmer, an outdoor lantern and the lighting breaker from the covers. Every switch front, ceiling rose and fitting stays shut.

  • Both positions of every switchMove each switch for that lamp to both positions, including a hall switch and a landing switch where two way switching is fitted. The lamp staying on in every position means the switch or the wiring between the switches needs a test.
  • A dimmer turned fully downTurn the knob fully down and operate the dimmer switch. A dimmer should make the lamp dim and then go off. A lamp that stays bright is still being fed by the dimmer or by a joint at the fitting.
  • An outdoor lantern in daylightLook at the lantern in daylight without opening it. Cover the sensor window with a card. A lantern that stays on has a stuck sensor or a switch that remains closed.
  • The lighting breaker handleThe lighting breaker is the switch on the fuse board that feeds the lights. Use that handle to turn the lights off and leave every screw in place. The lamp going dark shows the fault is on that circuit. The lamp staying lit means another feed is reaching it.

When should I book for a light that stays on?

Book Now when the lamp stays on in every switch position, or when a switch or fitting is hot, buzzing or smelling of burning.

  • The lamp stays on in every positionYou have moved each switch and the lamp still stays lit. A welded contact or a joint on the permanent live will keep feeding it. Book Now and leave the lighting breaker off if you want the lamp dark.
  • Heat, a buzz or a burning smellA warm switch, a buzz or a burning smell means the contacts are arcing. Arcing burns the plastic and the cable ends. Turn the lighting breaker off by its handle and Book Now.
  • A lantern that never goes darkA lantern that stays on through daylight, or after the sensor should have switched off, needs a test of the sensor and the switch. Keep the fitting closed and Book Now.
  • One lamp or every lamp on the switchOne lamp staying on while the others go off points to that fitting or its joint. Every lamp on the same switch staying on points to the switch or the cable from the fuse board. Book Now for either fault.

What happens on a visit for a light that stays on?

We switch off the lighting circuit, test the switch and the fitting, and name the failed part before we change it. Any repair waits until you have accepted it.

  • The lamp, the switches and the sensorWe ask which lamp stays on and which switches should control it. We ask whether it is a dimmer or an outdoor sensor, and when it started staying on. We read the lighting breaker with the fuse board cover still on.
  • Tests after the circuit is offWe turn the lighting circuit off and confirm there is no power before a cover comes off. We test whether the switch opens the feed to the lamp. We test the joints at the fitting. Those results separate a welded switch, a failed dimmer, a stuck sensor and a joint on the permanent live.
  • Earth path and supply before more workEarthing is the metal path that carries fault current so a breaker opens on a fault. Bonding joins metal pipes to the fuse board along that path. We check both. We also check whether the supply will feed the lighting load before we write a price for any work beyond this repair.
  • Repair, a retest and the certificateWe replace the failed switch, dimmer, sensor or joint after you have accepted the repair. We test the lighting circuit again. If that work changes the circuit, a minor works certificate records it with our NAPIT registration. A part that tests sound stays where it is.

What does tracing a light that stays on cost?

We charge fault finding and repair by the hour. The price covers tests on the lighting circuit, the diagnosis we give you, and the start of the repair after you have accepted it. Tracing two way switching across several switches takes longer than one switch in a single room. A replacement switch, dimmer or sensor, a minor works certificate, or an emergency electrician call out changes the price.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • A Varilight dimmer or a switch by MK Electric, BG Electrical, Hager, Wylex or Contactum is added only after the tests show it has failed.
  • A minor works certificate is charged when the repair changes the lighting circuit, and an EICR is priced as its own inspection of the installation.
  • A new fuse board waits for its own quote, and we write that quote only if the tests show the lighting breaker or the board has failed.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about a light that stays on

Still have a question?

Why will my light not turn off?

The switch, the dimmer, the sensor or a joint is still feeding the lamp. We test the lighting circuit and tell you which part has failed. The repair of that part waits until you have accepted it.

Should I turn the lighting breaker off?

Yes, if you want the lamp dark before the visit. The breaker handle on the fuse board switches off the lighting circuit and leaves the cover in place. Other circuits in the property stay on.

Will you change the switch straight away?

No. We name the failed switch, dimmer, sensor, joint or cable from the tests first. A switch that still opens the circuit stays on the wall. We fit a replacement only after you have accepted the repair.

Is an outdoor sensor light the same fault?

Yes. A PIR sensor should let the lantern go off after movement stops. A photocell should turn the lantern off in daylight. We test that device and the switch, and we replace only the part that has failed.

What certificate do I get after the repair?

You receive a minor works certificate when we change the lighting circuit. The certificate lists each test we completed on that repair, together with our NAPIT registration. An EICR is a wider inspection and we price it as another job.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)