MCB keeps tripping

An MCB that keeps tripping is the circuit breaker opening because that circuit is overloaded or shorted. Lighting Electrical in Peterborough tests the breaker and names the failed part.

Calls answered 24/7

  • 10 years trading

Why does an MCB keep tripping?

An MCB keeps tripping because its circuit is overloaded or the live and neutral have touched. An MCB is the small breaker in the fuse board that protects one circuit from too much current.

  • Too much load on one circuitThe rating is printed on the switch, such as B6, B16 or B32. Kettles, heaters and toasters running together can pass that current. The breaker opens to stop the cable overheating. The fault is the load, not a broken wire.
  • A short between live and neutralA short means live and neutral are touching, so a very high current flows. The MCB opens at once, even with every appliance unplugged. Crushed cable, a nail through a wire, or burnt contacts in a socket can make that short.
  • An appliance with an internal shortA kettle, heater, toaster or power tool can short inside its own body. The MCB for that circuit opens as soon as the plug goes in. Unplugging that one appliance lets the breaker hold. The appliance stays out of use.
  • A loose joint that is arcingA loose screw at a socket or a junction lets the conductors spark. That spark is arcing, and it chars the insulation until live and neutral meet. The MCB then opens. Heat or a burning smell at one fitting points to that joint.
  • A breaker that no longer holds its ratingAn old MCB can open below the current printed on its front. The circuit is sound and the load is normal, yet the switch drops. We change that breaker only after a test shows the device itself has failed. A sound breaker stays in the board.

What can I check before I book?

You can read the fuse board through the closed cover, pull the plugs, and reset the MCB once. You leave every cover screw in place and you do not touch any cable.

  • Which switch has droppedThe MCB is a narrow switch with a number such as B32 on the front. Note the name beside it, such as sockets, lights, cooker or shower. A wider switch with a test button is an RCD. An RCD turns off when current leaks to earth, which is a different fault from too much current. Leave the cover shut.
  • Unplug, then reset oncePull every plug on the circuit that dropped, including extension leads. If the board is cool, quiet and free of any burning smell, push the MCB up once. When the switch opens at once, leave that MCB down.
  • Plug appliances back one at a timeIf the MCB stays up, plug each appliance back on its own. The one that opens the breaker is the failed part. Leave that plug out. If the breaker holds with everything back in, the trip was too much load at once.
  • Heat, noise or a burning smellLook at the socket fronts and the fuse board cover. Brown marks, a buzz, or a smell of burning means stop. Leave the MCB down. Do not open the socket or the board.

When should I book for a tripping MCB?

Book Now when the MCB opens again after one reset, or when the board is hot, noisy or smelling of burning. A single trip from too many appliances, on a cool quiet board, can wait.

  • The MCB drops with nothing plugged inThe appliances are out and the switch still opens at once. The fault is in the cable, a socket, a joint or the breaker. Another reset warms the terminals. Leave the MCB off.
  • Heat, a buzz or a smell of burningA warm faceplate, a buzz, or brown marks means a joint is arcing. Switch that circuit off with the breaker handle. Keep your hands off the socket screws and the fuse board cover.
  • The same MCB trips on a normal loadThe switch stays up, then opens when you use an ordinary kettle or light. A loose joint, a damaged cable or a worn breaker can do that. Leave the MCB off and Book Now.

What happens on a visit for a tripping MCB?

We start at the fuse board, test the circuit with the MCB off, and name the failed part before we change it. Any repair waits until you have heard that finding.

  • Which circuit opened and whenWe ask which rooms went off, what was in use, and whether the MCB drops at once or after a delay. We read the breaker name with you. The cover stays on until a tester shows that circuit is dead.
  • Tests that separate the kind of faultWe isolate the circuit at the MCB. A dead test checks whether live and neutral are touching and whether current can leak to earth. The readings separate a short in the cable, a failed appliance, and a breaker that opens too soon.
  • The failed part, then the repairWe tell you what failed before a socket, a joint, a cable or the MCB is changed. You hear that finding first. We then replace the failed part and test the circuit again. If the repair changed the wiring, we write a minor works certificate that carries our NAPIT registration.
  • Earth path, bonding and the supplyBefore a further price we test the earth path that carries fault current away from you. We test the bonding conductors that join metal pipes to the fuse board. We also test whether the supply can carry the load already connected.

What does an MCB fault visit cost?

The time spent finding why the MCB opens sets the price for Electrical Fault Finding & Repair. That time covers the tests, the diagnosis we speak to you, and the repair after you accept the finding. A short that needs several sockets opened takes longer than one appliance. A new breaker, a minor works certificate, or a fuse board replacement changes the price.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • We fit a breaker, socket or length of cable only after the test shows that part has failed.
  • Hager, Wylex, Contactum, BG Electrical and MK Electric breakers are used when the failed device matches that board.
  • Fuse board replacement and emergency electrician attendance are each priced as their own jobs.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about an MCB that keeps tripping

Still have a question?

Is an MCB the same as an RCD?

No. An MCB opens on too much current or a short between live and neutral. An RCD opens when current leaks to earth and has a test button on the front. We test the device that is actually dropping, including an RCBO where one switch does both jobs.

Should I keep resetting the MCB?

One reset is enough, and only when the fuse board is cool, quiet and free of any burning smell. If the switch drops again, leave it off. Each extra reset warms the cable and the breaker.

Will you change the breaker before you know the cause?

No. We test the circuit and name the failed cable, joint, appliance or breaker first. Work on that part starts after you accept the finding. A breaker that still meets its rating stays in the board.

Do I get paperwork after the MCB is repaired?

If the repair alters the circuit, a minor works certificate records the tests and our NAPIT registration. An EICR is a separate inspection of the whole installation and is priced on its own. An appliance fault with no wiring change needs no certificate.

Will a new fuse board stop the tripping?

A new fuse board stops the tripping only when the tests show the breaker or the board has failed. A short in a cable or a socket still opens a new breaker. Fuse board replacement has its own written price after those tests.