Why does a plug melt?
A plug melts when a loose connection or too much current heats the plastic until it softens. The heat starts at the pins, the fuse or the cord grip, which is the clamp that holds the flex.
- Loose contact on the pinsThe brass pins need a tight grip in the socket. A loose grip sparks. That spark heats the pin until the plug body softens around it.
- A loose fuse or the wrong fuseThe fuse is the small cartridge in the plug that should open before the flex overheats. A loose fuse lets heat build in the plug. A fuse rated too high for the flex does the same.
- Too much load on one socketA kettle, a heater and a multi way adapter on one socket push more current through the contacts than they can pass. The contacts heat the plug pins and the plastic melts.
- A worn flex at the cord gripA flex that has been pulled, kinked or trapped wears where it enters the plug. Current heats the loose strands inside the body. The plastic melts before the fuse opens.
- A hot socket behind the plugBrown marks or soft plastic on the socket face mean the socket terminals are loose. Heat then travels into a sound plug and melts the body from the pins inward.
What can I check on a melted plug?
You can switch the socket off, pull a cool plug, and look at the outside of the plug and the socket. You leave the plug, the socket and the consumer unit closed. The consumer unit is the board that holds the breakers.
- The socket switch and a cool plugUse the switch on the socket face if it still moves freely. When the plug is cool, pull it straight out. Leave it out. Do not push it back in to see if it still works.
- The outside of the plugSoft plastic, a brown stain or a bent pin shows where the heat sat. You leave the plug closed. You do not fit a new fuse and try it again.
- The socket face and the smellA smell of hot plastic, or brown rings around the pin holes, means the socket has been hot as well. Leave that socket switched off. Leave the face screws in place.
- The breaker behind a closed coverLook through the closed cover of the consumer unit. A breaker is the switch that guards one circuit. If the socket breaker sits down, leave it down.
When should I book for a melted plug?
Book Now if the plug has changed shape, the socket smells of hot plastic, or brown marks sit around the pin holes.
- A plug that has lost its shapeSoft, bubbled or cracked plastic means the connection has already overheated. Book Now. Keep that plug out of every socket in the house.
- A brown, hot or smelly socketBrown rings, a warm face or a smell of hot plastic mean the socket is part of the fault. Switch it off at the socket if the switch still moves. Leave the breaker down if it has opened.
- A second plug melted in the same socketTwo damaged plugs from one outlet mean the socket contacts are failing. Stop using every socket on that circuit until the circuit is tested.
What happens on a melted plug visit?
We isolate the circuit, compare the melted plug with the socket, and name the burnt part before any fitting is changed.
- The circuit switched off firstWe ask which socket held the plug and whether you smelt hot plastic. We switch that circuit off at the consumer unit. We prove the circuit is dead before a screw comes out.
- The plug compared with the socketWe look at the melted plug, the flex and the socket face. Scorch on the pins with a clean socket points to the plug. Scorch on the socket with a sound flex points to the socket terminals.
- Measurements on the dead circuitWith the circuit off we measure the cable for a break and for leaking current. Earth is the safety path that lets a breaker open. The readings separate a bad plug, a bad socket and a damaged cable.
- The repair and the certificateWe name the failed part. We fit a socket or a plug connection only after you accept that work. Where the circuit is altered we record the tests on a minor works certificate on our NAPIT registration. A sound socket stays closed.
What does a melted plug visit cost?
The price covers attendance, tests on the circuit that fed the melted plug, and leaving that circuit safe. Fitting a socket, renewing a damaged flex connection, or writing a minor works certificate changes the price. Emergency electrician work is charged apart from a later repair booked in opening hours.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- A single scorched socket takes less time to trace than heat damage along the cable back to the consumer unit.
- We fit an MK Electric, BG Electrical, Hager, Wylex or Contactum socket only after the test shows the one on the wall has failed.
- A scorched breaker means a consumer unit change is quoted as a separate job from the melted plug visit.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan I put a new fuse in and use the plug?
No. A melted body means the plug has already run too hot, so a new fuse does not make it safe. The fuse is the cartridge that should have opened first. Leave the plug out and have the socket tested.
Is the appliance ruined if the plug melted?
The appliance can be sound when the heat started in the plug or the socket. We name the plug, the socket or the flex before any part is replaced.
Will the rest of the house lose power?
We switch off only the circuit that fed the hot socket. Other circuits stay on. That circuit goes back on after the repair, and it stays off if it is still unsafe.
Do you replace the socket on the same visit?
We replace the socket on the visit when the test shows it has failed and you accept the repair. A damaged flex needs a new plug connection. A sound socket is left as it is.
What paperwork do I get after the repair?
A minor works certificate records a socket or circuit change and the test results, with our NAPIT registration on it. If we only make the circuit safe and change nothing, we write down the readings and the failed part.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
Sources
- Electrical Safety First: Plugs and fuses (BS 1363 plugs, BS 1362 fuses)
- Electrical Safety First: Overloading sockets
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 16 November 2026