Why does metal give a mild electric shock?
Metal gives a mild shock when a fault puts voltage on a tap, a radiator or an appliance case. The voltage comes from the supply earth, from missing pipe bonding, or from a leaking circuit.
- A broken PEN in the supply cableMost supplies use one conductor as the neutral and the earth together. That conductor is called the PEN. A break in the PEN raises the voltage on bonded taps and radiators. Lamps that brighten and dim show the same break. The electricity network repairs that supply conductor.
- Bonding missing from the pipesBonding is the green and yellow link between metal pipes and the earth bar in the fuse board. A missing or loose link leaves a voltage between the tap and the floor. Wet hands feel that voltage as a tingle.
- An appliance case with a leakDamaged insulation inside a washing machine, cooker or heater puts voltage on the metal case. An RCD is the switch that opens when current leaks off the circuit. With no earth wire back to the fuse board, the case stays live and the RCD stays on.
- A shower rail felt with wet handsWet skin passes current far more easily than dry skin. A small voltage on a shower rail, tap or heated towel rail then feels sharp. The earth wire to that rail gives the RCD a path to trip. No earth wire means the rail can tingle while the RCD stays on.
- Outside metal on a PME supplyPME means the supply earth and the neutral are joined. Outdoors the paving is true earth and a bonded outside tap is PME earth. Bare wet feet on that paving, with a hand on the tap, complete a path for the difference. People feel the same thing on hot tub metal.
What can I check without opening anything?
You can record which metal tingles and read the fuse board through its closed cover. Covers stay on. Gas pipes, refrigerant pipes and bare wires stay untouched.
- Which metal tinglesNote every item that tingles, such as the kitchen tap, a radiator, the washing machine case or an outside tap. Several items at once point to bonding or the supply earth. One appliance case points to that appliance alone.
- Whether the lamps change brightnessWatch the lamps without touching the metal. Lamps that brighten and dim while the taps tingle match a broken PEN in the supply cable. The electricity network takes street cable faults on 105. Book Now so the house circuits can be switched off.
- One appliance unpluggedWhen a single case tingles, switch that appliance off and pull the plug out by the plug. Leave the case screws in. If the taps still tingle with the plug out, the fault is in the fixed wiring or the supply earth.
- The RCD behind a closed coverAn RCD is the fuse board switch with a test button. Read it through the closed cover. Leave it off if it has already tripped and the board is warm, buzzing or smelling of burning. Reset it once only when the board is cool and quiet, then leave it off if it trips again.
When should I book for a shock from metal?
Book Now if the tingle comes back, if several metals tingle, or if the lamps change brightness.
- The tingle happens againA single snap after walking on carpet is static on your body. A tingle every time skin meets a tap, a radiator or a metal case is voltage on the metal. Stop using that metal and Book Now.
- Taps and lamps misbehave togetherTingles on both taps and radiators, or lamps that change brightness, need the supply earth tested before that metal is used again. Book Now for the house installation. 105 is the electricity network number for the cable in the street.
- The RCD will not stay onAn RCD that opens again after one reset still has a leak to clear. A burning smell at the fuse board means the same. Leave the switch off and Book Now.
What happens on a visit for a shock from metal?
We ask which metal tingled and whether the lamps changed brightness. We then test earthing and bonding before any repair is priced.
- Where the shock was feltWe ask which tap, radiator, rail or appliance case tingled. We ask whether the lamps changed brightness and whether one appliance was running. The cover remains closed while we read the switches with you.
- Tests on earthing, bonding and the circuitWe switch off the suspect circuit and prove it dead before any conductor is touched. Earth continuity shows whether the earth wire is intact. An insulation test shows current leaking onto metal. A supply earth test shows the state of the PEN. Bonding tests show whether the pipes reach the earth bar.
- The failed part named before a repairWe name the failed part before any fitting is changed. The part is a bonding link, an earth wire, an RCD, or the supply conductor in the street. The electricity network repairs the street conductor. We start house wiring only after you accept the price.
- The circuit tested again or left offWe repeat the tests after any repair you have accepted. We record an altered circuit on a minor works certificate carrying our NAPIT registration. Where the tests show the metal stays live, we leave that breaker off and write down the readings.
What does a metal shock visit cost?
The emergency electrician price covers the visit, the tests on earthing, bonding and the leaking circuit, and leaving that circuit safe. More time on extra circuits, a part fitted after the tests, or a minor works certificate changes the price. Fuse board replacement and an EICR are priced as their own jobs. An EICR is an Electrical Installation Condition Report on the whole installation.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- A tingle on one appliance takes less testing time than a check of every bonding link and the supply earth.
- A failed bonding clamp, RCD or breaker from Hager, Wylex, Contactum, BG Electrical or MK Electric is added to the price.
- A failed fuse board is then priced on its own as fuse board replacement.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs a mild tingle from the tap serious?
Yes. The tingle is voltage on metal your hand already touches, and wet skin lets more current through the body. Keep off that tap and Book Now so we can test the earthing.
Do I phone the electricity network?
Phone 105 when lamps brighten and dim and the taps tingle as well. That pattern is a broken PEN in the supply cable, which the electricity network repairs. We test the house earthing and bonding and switch off every circuit that leaves metal live.
Will a new fuse board stop the shock?
A new fuse board stops the shock only when the readings show the board or its RCD has failed. A sound board stays. We price fuse board replacement on its own, and we do not start that job from the shock visit alone.
Do I receive paperwork after the visit?
The minor works certificate covers a bonding link, a cable or a device we have changed. It lists the new test results beside our NAPIT registration. If we isolate the circuit and fit nothing new, you get the readings and the name of the failed part.
Can I still shower if the rail tingles?
No. Switch the shower circuit off at the fuse board and leave the rail alone. We test the earth to the rail and the RCD for that wet room before the circuit is switched on again.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
Sources
- IET: Broken PEN
- IET: hot tubs, perceived shock on PME
- HSE: electrical injuries
- Call 105 for the local electricity network