Neighbours have power but I don't
A dark house while next door stays lit has a tripped main switch, a blown service fuse or a meter that has cut the supply. Lighting Electrical tests those three points from its Peterborough base.
Calls answered 24/7
- 10 years trading
Why is the house dark when the neighbours have power?
The property loses power on its own when the main switch trips, the service fuse blows or the meter switches the supply off.
- The main switch or main RCD has trippedA tripped main RCD or main switch cuts every circuit at once. An RCD is the safety switch that shuts off if electricity leaks away from a circuit. Where that switch feeds the whole board, one leak puts every room into darkness. A heavy short on a socket circuit drops the main switch as well.
- The service fuse has blownA blown service fuse cuts power to the meter and the fuse board together. The service fuse is the network operator's cartridge in the sealed holder beside the meter. Next door stays on because that fuse serves this property alone.
- The meter has switched the supply offA prepayment meter cuts the supply when the credit runs out. A smart meter cuts the supply when the supplier disconnects it. The meter screen states the reason. The fuse board receives no live feed until the meter closes.
- Burnt meter tails or a burnt main switchA burnt joint in the meter tails or the main switch opens and the property goes dark. Meter tails are the thick cables that link the meter to the fuse board. Scorch marks, heat or a smell of burning at the board show that this connection has failed.
- A separate isolator has failedA failed or switched off isolator leaves the fuse board dead while the meter stays live. An isolator is a switch fitted between the meter and the fuse board. It disconnects live and neutral together.
- The cable from the street main has failedA failed service cable leaves this meter dead while neighbouring homes stay lit. The service cable brings power from the street main to this property only. The network operator repairs that cable.
What checks are safe when next door still has power?
You can read the main switch, the meter screen and any separate isolator with the covers left on. No screw comes out and no cable is touched.
- Read the main switchThe main switch position shows whether the whole board has been switched off. Look at the fuse board with the lid left closed. The main switch is the widest one on the board. It feeds every circuit in the property. Lift it once if it is down and the board is cool and quiet. Leave it down if the power drops straight away.
- Read the electricity meterA message about credit or disconnection means the meter has opened the supply. Top up a prepayment meter or speak to the supplier. A meter with no lights and no screen points to the service fuse.
- See if every circuit is deadEvery circuit being dead places the break ahead of the individual breakers. Try one light upstairs, one kitchen socket and the boiler switch. One room still working means only that circuit has dropped.
- Compare the lights next doorSteady lights next door mean the street mains are up. This property has lost its own supply. Ask one neighbour whether their lights are steady and at normal brightness. Dim, bright or flickering lights in both homes go to 105, the free power cut line.
- Notice heat, noise or smellHeat, noise or a burning smell means a joint is failing. Pause beside the fuse board and the meter. Leave every switch where it is and keep clear of the board.
When is an electrician needed for one dark house?
Book Now when the main switch will not stay up, the meter is live while the house is dark, or the board smells of burning.
- The main switch will not holdAnother trip after the plugs are pulled means leakage on the fixed wiring or a worn main RCD. Repeated resets heat the switch and the cables. The visit tests each circuit and leaves the bad one off.
- The meter is live but the house is darkLights on the meter and no power in any room mean the supply stops in the tails, the isolator or the main switch. Those parts sit under covers. A tester has to show those cables are dead before a cover comes off.
- The board is hot, buzzing or smellingHeat, a buzz or a burning smell at the meter or the fuse board means a joint is breaking down. Put the main switch down from the toggle on the front. Keep your hands off the cables and the cover.
- The meter is dark as wellA blank meter and a dark house point to the service fuse or the service cable. We confirm that with a voltage test on the incoming terminals. The network operator then changes the fuse or repairs that cable.
What happens on the visit for a fully dark house?
The visit runs from the meter to the main switch and then through each circuit. Any failed part stays isolated at the end.
- Voltage test at the meterA voltage test at the meter shows whether any supply is arriving. We read the meter screen with you. A tester then checks for voltage on the supply coming into the property. No voltage means the service fuse or the service cable has failed. The seals stay untouched.
- Tests on the tails and the main switchLive voltage at the meter with a dead fuse board moves the test to the isolator, the meter tails and the main switch. A burnt or open joint shows between those points. We leave the failed joint disconnected while testing carries on.
- Finding the circuit that drops the main RCDEvery breaker goes off before we close the main RCD. Each circuit then comes back on its own. The one that drops the RCD stays off. A further test separates a damp fitting, a damaged cable and a failed RCD.
- Sound circuits back on and the next job pricedCircuits that hold remain on. The kitchen and the heating run again where their own circuit held. One failed circuit stays off. Before we price a repair, we check earthing, bonding and spare capacity in the supply. The Minor works certificate covers a change to a breaker, a switch or a cable. Fuse board replacement carries its own written price.
What does a single house power loss visit cost?
Emergency electrician pricing is the time spent at the property. That time covers attendance and the voltage tests. Switching the failed part off is included in that time. A main RCD that holds once the bad circuit is off takes less time than burnt meter tails. We write a parts price for burnt tails before fitting them.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- We write up a new main switch, RCD or run of meter tail from Hager, Wylex, Contactum, BG Electrical or MK Electric before fitting it.
- The emergency electrician rate applies outside opening hours and the fault finding rate applies during opening hours.
- Fuse board replacement gets its own written price when the existing board cannot be left safe.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowIs it a power cut if my neighbours have electricity?
A network power cut drops neighbouring homes at the same time. Power still on next door means the main switch, the service fuse or the meter on your supply has opened. We test those three and name the one that failed.
Should I call 105 or book an electrician?
Call 105 when next door is dark or the street lights are out as well. Book Now when next door is normal and your house alone is dead. We test the incoming supply. A failed service fuse goes to the network operator.
Will the kitchen work again before the repair is finished?
The kitchen comes back where the main switch holds with the failed circuit switched off. Healthy circuits go back on. The kitchen returns with them when its circuit is healthy. A blown service fuse keeps the whole house off until the network operator changes it.
Do you change the fuse board on the same visit?
Fuse board replacement happens on the visit only after you accept a written price and the board can be left safe. The failed circuit stays off until the new board has its own price. We test the work we complete before we leave the property.
What paperwork do I get after a repair?
A change to a breaker, a switch or a cable includes a minor works certificate for that circuit. Lighting Electrical is NAPIT registered. The test results are written on the certificate. Isolation with no alteration leaves a written note of the failed part and the readings.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
Sources
- UK Power Networks: Power Cut Help
- Energy Networks Association: Power Cut Information
- Electrical Safety First: Safety Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 16 November 2026