Outdoor socket not working
An outdoor socket with no power has a tripped protective device, water in the outlet, or a break in its cable. Lighting Electrical in Peterborough tests that point and names the failed part.
Calls answered 24/7
- 10 years trading
Why does an outdoor socket stop working?
An outdoor socket stops working when water reaches the contacts, its safety switch opens, or the outdoor cable breaks. Indoor lights can stay on because they use another circuit.
- Water in the outdoor outletRain or a failed seal lets water sit across the live contacts. Current then leaks to earth, the safety path that carries a fault away from you. The protective device opens and the outdoor socket goes dead.
- A tripped RCD or RCBOAn RCD is a switch that opens when current leaks to earth. An RCBO does that job for one circuit and also opens on overload. Damp in an outdoor socket opens that device, so the outlet stays dead until the leak is removed.
- A cracked or faded socket faceSun and frost crack the plastic and the cover. The contacts corrode and a plug makes a poor joint. The outlet then loses power, or it trips when the plug is moved.
- A damaged outdoor cableThe cable to a garden socket is often armoured, with a metal sheath under the outer plastic. A crushed sheath, a loose gland or a cut beside a patio opens the circuit. A gland is the fitting that seals the cable where it enters the box.
- A failed joint in an outdoor enclosureAn outdoor distribution enclosure holds the socket, the earth bar and the incoming cable. A loose terminal in that box heats and opens the circuit. Sockets indoors can stay live on their own breakers.
What can I check on a dead outdoor socket?
You can look at the closed fuse board, unplug garden appliances and see whether the socket face is wet or cracked. You leave every cover screw in place.
- The garden switch on the fuse boardThe fuse board is the box of switches that protect each circuit. With the cover shut, see whether the switch marked outside, garden or garage sits down. Reset it once only when the board is cool, dry and quiet.
- Plugs removed from the outdoor socketUnplug the mower, the lights and any extension lead. When the socket and the ground are dry, reset the outdoor switch once. If it opens again, leave it off.
- Cracks, water or brown marksLook at the socket face and leave the screws in place. Water in the cover, a cracked lid or brown marks around the pin holes mean the joint is failing. Keep your hands away from the contacts.
- Whether indoor sockets still workPlug a lamp you already trust into a nearby indoor socket. Indoor sockets that work mean the fault is on the outdoor point or its cable. Indoor sockets that are also dead mean one device has opened for both.
When should I book for an outdoor socket?
Book Now when one reset fails, the socket is wet or cracked, or you smell burning. A dry socket that works after you unplug one faulty garden light can wait.
- The outdoor switch will not holdThe plugs are out and the switch still drops. The fault is in the socket, the cable or the device. Leave the switch off and Book Now, because another reset heats the joint.
- Water, cracks or brown marksA wet face, a split cover or scorch marks mean current can leak to earth. Leave that circuit off. Book Now before anyone uses the socket again.
- Power fails only after rainThe socket works in dry weather and dies after rain. Water is entering the outlet or the enclosure. Book Now so the leak is found before the terminals corrode.
What happens on an outdoor socket visit?
We start at the fuse board, isolate the outdoor circuit and name the failed part before we change the socket or the cable. Any repair waits until you accept it.
- What died and whenWe ask whether the socket failed after rain, after a plug was moved, or all the time. We read the outdoor switch with you while the fuse board cover stays shut. We note any appliance already unplugged.
- Tests on the isolated circuitWe switch that circuit off. Tests on the dead cable show a leak to earth, a broken conductor or a failed device. We name the socket, gland, cable or protective device before we fit anything.
- The outdoor socket or enclosureWe open only the outlet or enclosure the tests have shown has failed. A sound socket stays shut. We check the gland and the earth connection in that box.
- Repair and the certificateWe fit the failed part after you accept the repair. We test again and issue a minor works certificate when the outdoor circuit was altered, under our NAPIT registration. Before a further price we confirm earthing, the fault path back to the fuse board, and bonding, the link from metal pipes to that path.
What does an outdoor socket fault cost?
Hourly fault finding pays for the outdoor tests, the spoken diagnosis and the repair after you accept it. Time rises when we trace a buried cable or open an enclosure. A weatherproof socket, a protective device or a minor works certificate is added only when the finding needs it. Emergency electrician work is priced as its own job.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A wet enclosure or a long outdoor cable takes more time than a socket that trips as soon as one plug goes in.
- We fit a weatherproof socket, a breaker or a length of cable only after the tests show that part has failed.
- A new fuse board is priced on its own when the outdoor tests show the board has failed.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWhy does my outdoor socket trip when it rains?
Rain across a cracked seal bridges the contacts and current leaks to earth. The RCD or RCBO opens and cuts the outdoor socket. We test the outlet and the cable, then repair the part that lets water in.
Should I keep resetting the outdoor breaker?
One reset is reasonable after every plug is out, and only while the fuse board is cool, dry and quiet. If the switch drops straight away, leave it off. Further resets heat a wet or loose joint.
Will you change the outdoor socket before you know the cause?
The tests come first and we tell you whether the socket, the gland, the cable or the device has failed. A new outdoor socket goes on only after you accept that repair. An outlet that tests sound stays closed.
Do I get paperwork after the outdoor socket is repaired?
A minor works certificate follows when we alter the outdoor circuit. It lists the test results for that repair and shows our NAPIT registration. An EICR, the Electrical Installation Condition Report, inspects the whole installation and is arranged as its own job.
Does the outdoor socket need a new fuse board?
Only when the tests show the board or its outdoor device has failed. A damaged socket or cable still leaves the outlet dead on a new board. Any board change is priced as its own job.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
Sources
Updated 16 November 2026