Power keeps cutting out on and off

Power that cuts out and comes back points to a switch on the board reacting to a leaking appliance, damp outdoors or a loose connection. Lighting Electrical, based in Peterborough, tests each circuit until the readings show which.

Calls answered 24/7

  • 10 years trading

Why does my power keep cutting out?

Power that goes off and comes back means a switch on the fuse board is reacting to a fault that only appears under certain conditions, or the network outside has dipped for a moment.

  • Small leaks adding up on one RCDThe residual current device, or RCD, on the board trips when current escapes to earth. Every appliance lets a tiny amount escape. Where one RCD covers many circuits, those amounts add together, and one more appliance switching on pushes the total over the trip point.
  • An appliance that fails only when it runsA fridge freezer compressor, a washing machine heater or an immersion element can leak current only at the moment it switches on. The power then drops at odd times, including overnight when nobody is using anything.
  • Damp in outdoor sockets and lightsRain or condensation inside an outside socket, garden light or outbuilding supply lets current track to earth. The trips follow wet weather and stop once the fitting dries out.
  • Too much load on one circuitEach circuit has a breaker, a switch sized for the current that circuit can carry. A kettle, heater and tumble dryer running together on one circuit can pass that rating. The breaker drops and the rest of the house stays on.
  • A loose or overheating connectionA terminal that has worked loose at a socket, switch or the board makes and breaks contact as it heats and cools. Lights flicker or a run of sockets goes off and comes back, with no switch tripped at all.
  • Brief faults on the network outsideA short drop across the whole street comes from the network, and the operator's equipment restores it within seconds. Clocks on ovens and microwaves reset while every switch on the board stays up.

Which checks are safe to do myself?

You can keep a record of each cut, read the board through its closed cover and take appliances out of use one by one, all without opening anything.

  • Write down every cutNote the time, the weather, which appliances were running and how long the power stayed off. A pattern, such as trips after rain or at the same hour each night, points straight at the cause.
  • See which switch has movedLook at the board with the cover left on. A dropped RCD takes several circuits with it, while a dropped breaker affects one circuit. If nothing has moved, the cut came from a loose connection or the network.
  • Take suspect appliances out of useLeave one appliance unplugged for a few days at a time, starting with the fridge freezer, the washing machine and anything kept outdoors. If the trips stop, that appliance needs repair or replacing.
  • Ask the neighboursAsk whether their power dipped at the same moment. If it did, the network operator deals with it, and you can report it on 105, which is free to call.

When do intermittent power cuts need an electrician?

Book a visit once the trips keep coming back with the suspect appliances unplugged, or at the first sign of heat anywhere on the installation.

  • Trips continue with appliances unpluggedA cut that returns with the likely appliances out of use points to the fixed wiring or the board itself. Resetting it again and again will not cure it.
  • Lights flicker or dim before the power goesThat pattern points to a loose connection arcing as it heats. Arcing is a spark jumping across a gap, and it scorches the terminal and the cable behind it.
  • Warmth, buzzing or a burning smellKeep the affected circuit switched off until it is tested. Heat at a socket, switch or the board means a connection is breaking down.
  • The trips are getting more frequentA fault that cut the power once a month and now does it every week is getting worse. Insulation that has started to break down does not recover by itself.

How is an intermittent fault found?

The visit starts with your record of the cuts, then tests each circuit until the readings show which one is responsible.

  • Going through your recordWe ask about the times, the weather and what was running for each cut, and look at which switch dropped. That pattern tells us which circuits to test first.
  • Measuring leakage on each circuitAn earth leakage clamp is a meter that reads the current escaping to earth while the circuit stays live. Circuits that each leak a little but trip the RCD together show up on the clamp.
  • Insulation resistance and RCD testsWith a circuit isolated, an insulation resistance test checks how well the cable keeps current where it belongs. We also time the RCD to confirm it trips when it should and not early.
  • Putting the fault rightOnce you accept the repair, we fix the loose terminal, damp fitting or faulty breaker and retest the circuit. Where shared RCD cover is the cause, moving circuits onto RCBOs, each a breaker and RCD in one, gets its own written price. You receive a minor works certificate for any repair that changes a circuit.

What does tracing an intermittent fault cost?

Fault finding is charged by the hour, so the price covers time spent testing at the board and along each circuit, the diagnosis we give you, and the repair once you accept it. A fault that has to be caught in the act takes longer to trace, so a detailed record of each cut shortens the visit.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • Replacement parts, from a breaker to a weatherproof outdoor socket, cost extra on top of the hours.
  • Moving circuits onto RCBOs or changing the board is priced in writing as its own job before any of it starts.
  • Attendance outside opening hours is charged at the emergency electrician rate instead.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about power cutting out

Still have a question?

Why does my power trip at night when nothing is on?

Some things still run at night, such as a fridge freezer, an immersion heater on a timer or a heating pump. When one of them switches on with a fault, it leaks current and the RCD drops. Taking them out of use in turn over a few nights shows which one.

Will a new fuse board stop the power cutting out?

Only when the board itself is at fault. A new consumer unit with the leaking appliance or damp fitting still connected trips just the same. The cause is tested first, and a board change is priced separately when the readings call for one.

Can you find the fault if it does not happen while you are here?

Most faults give readings on test even when the power is on, because a leaking circuit or an overheated connection shows on the meter. If every reading passes, you get the results and a short list of things to note when the next cut happens.

How many times should I reset a tripping switch?

Once or twice is fine while you work out which appliance is to blame. A switch that drops again at once, or trips several times a day, is showing you a fault. Leave it off and Book Now for a test.