Power surge damage to electrics

A power surge damages electrics by forcing a high voltage through appliances and the fuse board. Lighting Electrical traces that damage in Peterborough and names each failed part.

Calls answered 24/7

  • 10 years trading

Why does a power surge damage electrics?

A surge is a brief voltage spike above the normal supply, and it pushes excess current through appliances, joints and protective devices. The cable, the fuse board or a plugged in appliance can fail while other circuits stay on.

  • A spike from the supplyLightning or a fault on the network lifts the voltage for a fraction of a second. That spike arrives at the fuse board and passes into every circuit that is switched on.
  • A large motor switching offA pump, a compressor or another motor can kick voltage back onto its circuit as it starts or stops. Electronics on that circuit see the spike even when the motor still runs.
  • A missing or spent surge deviceA surge protection device, called an SPD, sits in the fuse board and clamps a high voltage. An older board may have no SPD. A device that has already clamped a surge shows a failed flag and does not clamp the next one.
  • A loose terminal that overheatsThe spike heats a loose terminal in a socket, a switch or the fuse board. The joint chars, the breaker opens, and the circuit stays dead after the supply voltage has settled.
  • Electronics that cannot take the spikeChargers, alarm panels, boiler controls and televisions use small electronic parts. Those parts fail at a voltage the house cable can still carry, so the appliance dies while the circuit looks intact.

What can I check safely after a power surge?

You can look at the fuse board, unplug damaged appliances and note what died. Appliance cases stay shut, and the fuse board cover stays on.

  • Switches seen through the coverA breaker or an RCD sitting down has opened. An RCD is the safety switch that trips when current leaks to earth. Reset it once only if the board is cool, quiet and free of any burning smell.
  • Plugs with heat or brown marksUnplug any appliance that is dead, hot or smelling of burnt plastic. Brown marks on the pins mean the plug has been overheating. Leave the appliance case closed.
  • One appliance or several roomsWrite down whether one appliance died or several rooms lost power together. Several rooms point to the fuse board or the incoming supply. One appliance points to that appliance or the socket it used.
  • A flag on the surge deviceSome fuse boards show a small window on the SPD. A changed colour or a failed mark means the device has already operated. You do not remove the cover to hunt for that window.

When should I book after surge damage?

Book Now if a breaker will not hold, if you smell burning, or if several appliances failed at the same moment.

  • The switch opens againDamaged appliances are unplugged and the breaker still drops. The fault remains in the fixed wiring or in a protective device. Leave that breaker off.
  • Heat, smell or scorch marksA burning smell, a warm faceplate or brown marks on a plug mean a joint is failing. Switch that circuit off with the breaker handle. Keep your hands off socket screws and the board cover.
  • Many appliances dead togetherTwo or more appliances failing in the same moment means the spike reached the fuse board. The surge device and the circuits need a test before those appliances are plugged in again.
  • The surge device shows failedA failed mark on the SPD means the next spike has nothing to clamp it. The board and the device need a test. Leave the cover screwed on.

What happens on a surge damage visit?

On a visit in Peterborough we isolate the damaged circuits, test them, and name the failed part before any fitting is changed.

  • Which appliances and breakers failedWe ask what died, whether a storm or a trip came first, and which breakers are down. The cover stays shut until a tester shows the circuit is dead.
  • Measurements on the dead circuitsWe switch off the damaged circuits and test them while they are dead. An insulation test looks for leaking current between the conductors. A continuity test checks that the copper still joins end to end.
  • The SPD and the device that openedWe check whether an SPD is fitted and whether its flag shows it has operated. We then test the RCD or RCBO that opened. An RCBO combines a breaker and an RCD in one device for a single circuit.
  • The repair and the certificateWe name the failed part and change it only after you accept the repair. We test the circuit again. Where the circuit changes, a minor works certificate records the tests under our NAPIT registration. Before a further price we check earthing, the fault path back to the board, and bonding, the link from metal pipes to that earth, plus whether the supply can carry another load.

What does a surge damage visit cost?

The price follows the hours spent on Electrical Fault Finding & Repair. Those hours cover the tests after the surge, the diagnosis we give you, and the start of the repair once you accept it. A longer test on several circuits, a replacement SPD or breaker, or a minor works certificate changes the price. Fuse board replacement is priced on its own when the tests show the board has failed. Emergency electrician attendance is a separate job.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • One dead appliance needs less testing than a spike that has opened several circuits.
  • An SPD for a Hager, Wylex or Contactum board is fitted only when the test shows the device has failed.
  • A new fuse board carries its own price when the surge has damaged the board.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about power surge damage

Still have a question?

Can one surge damage several appliances?

Yes. A single spike can reach every appliance that was plugged in and switched on. We test the fuse board and the circuits as well, because a dead appliance can sit next to a damaged protective device.

Should I reset the breaker more than once?

One reset is reasonable after damaged appliances are unplugged, and only while the fuse board stays cool and quiet. If the breaker opens again, leave it off. Further resets heat a joint the spike has already damaged.

Will a new fuse board undo the surge damage?

Only if the tests show the board or its SPD has failed. A sound board stays in place and the failed socket, joint or appliance is repaired instead. Any board change is priced on its own after those tests.

What paperwork follows a surge repair?

Where we alter a circuit, a minor works certificate lists the tests for that alteration and our NAPIT registration. If we only isolate a dangerous circuit and change nothing, you still get the readings and the named fault. An Electrical Installation Condition Report, an EICR, inspects the whole installation and is arranged as its own job.

What if only one appliance is burnt?

The appliance may be the only failed part. We test the circuit with that appliance unplugged. If the wiring and the protective devices pass, the circuit goes back on and the appliance stays unplugged.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)