Why does my RCD keep tripping?
An RCD keeps tripping because current leaks to earth and the safety switch opens. In Peterborough, Lighting Electrical tests the fuse board and those circuits and names the leaking part.
Calls answered 24/7
- 10 years trading
Why does an RCD keep tripping?
An RCD, short for residual current device, keeps tripping because current leaks away to earth. The device compares current going out on the live wire with current coming back on the neutral wire, and it opens when they differ.
- An appliance leaking currentA kettle, a washing machine or an immersion heater leaks current to its metal body when the insulation inside fails. The RCD opens and cuts the power. With that appliance unplugged, the switch stays up when nothing else is leaking.
- Water at a socket, fan or showerRain in an outside socket, steam in a bathroom extractor fan, or water at an electric shower lets current cross from live to earth. The RCD opens on that cross. A soaked cable keeps leaking after the surface looks dry.
- Neutral joined to earthThe neutral carries current back to the fuse board and has to stay off the earth wire. A trapped strand bridges the two. A borrowed neutral, a neutral taken from another circuit, does the same. The RCD opens on that bridge with every appliance unplugged.
- Small leaks adding up on one RCDA split load board is a fuse board that puts one RCD over a group of circuits. Small leaks on those circuits add up on that one switch. The RCD opens when the total is enough, even while each appliance still runs.
- A failed RCD or RCBOAn RCBO guards one circuit and also opens when current leaks away. A failed RCD opens while the wiring still tests sound. We name the device from the test before any replacement is fitted.
What can you check safely if an RCD keeps tripping?
Read the closed fuse board, pull the plugs on circuits that died, and reset the RCD once if the plastic is cool and silent. Leave every screw where it is. Do not open an appliance and do not touch a wire.
- The switch with a test buttonAn RCD has a test button on the front. A plain breaker has no test button and opens on overload in one circuit. Read both through the cover, which stays on, and note which switch is down. That device is the one to report.
- Plugs out, then one resetPull every plug on the circuits that went off, including extension leads. Push the RCD up once. If it holds, plug each appliance back one at a time and note which one opens it. The name of that appliance is what we need reported.
- A trip with all plugs removedThe leak is in the cables in the walls, a wet fitting or the RCD itself when the switch opens at once with every plug out. Leave the switch down. Another reset warms the terminals.
- Rain, the shower or a burning smellNote if the RCD opens in the rain, when the shower runs, or with a burning smell. Note which rooms lose power. Those notes show where the test starts.
- What to report with the bookingWrite down the time of the trip, the rooms that lost power, the appliance in use, and any rain or shower. Have those notes ready on the visit. They point the tests at the right circuit.
When should you book for a tripping RCD?
Book Now when the RCD opens again with every plug removed, when the board smells of burning, or when water is on a socket or fitting. A single trip that does not repeat after one appliance is unplugged belongs to that appliance. Cables buried in the walls are a separate fault.
- It opens with nothing plugged inEvery appliance is unplugged and the RCD still opens at once. The leak is in a cable, a fitting or the device. Leave the switch off, because another reset warms the terminals.
- Heat, a buzz or a burning smellHeat, a buzz or a burning smell at the fuse board means a joint is sparking. A spark across a loose joint is called arcing, and it chars the plastic. Use the main switch on the front of the closed board to cut the supply and Book Now.
- Water present when the RCD opensRain in an outside light, a drip above an extractor fan, or a puddle by a socket lets current leak as soon as the RCD is raised. Leave that RCD off. The wet circuit needs a test before it goes back on.
- Lights and sockets off togetherOne RCD feeds a group of circuits, so the rooms on that group go off together. A reset does not reveal which circuit is leaking. Book Now and name the rooms that died together.
What happens on a visit for a tripping RCD?
We test the RCD and every circuit it feeds, then name the leaking part before a repair. The repair starts only once you want it done. Where we alter the circuit, we write a minor works certificate to record the tests.
- The time, the rooms and the switchWe ask when the trip happened, which rooms lost power, and which appliance was in use. We stand with you beside the shut fuse board, also called the consumer unit, and note which switch is down. A test button on that switch shows it is an RCD.
- Insulation tests, circuit by circuitWe switch the RCD off and disconnect each circuit neutral so the meter sees one circuit at a time. An insulation test applies a voltage to the cable and reads any current escaping to earth or across to another wire. Those readings separate a wet fitting, a damaged cable, a join between neutral and earth, and a failed device.
- The cause, the earth path and the supplyWe name the appliance, cable, fitting or RCD before any part is swapped. We measure the earth conductor, which is the path that fault current takes back to the supply. We check that metal pipes and the bath link to that earth. We check the supply has room for a further load before we price any further load.
- Repair of the named partWhen you want the repair done, we replace the failed fitting, cable or device and test the RCD again. A minor works certificate records that work and shows our NAPIT registration. We leave the RCD off when the leak is still present. Circuits on another device stay on.
What does a tripping RCD visit cost?
We charge Electrical Fault Finding & Repair by the hour when an RCD keeps tripping. That hour pays for tests on the device and on each circuit it feeds, for telling you the cause in plain words, and for the repair when you want it done. Finding one leaking appliance uses less of the hour than testing several circuits grouped on one RCD. We change the price when you need a new device, a minor works certificate or a fuse board replacement.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- We fit an MK Electric, BG Electrical, Contactum, Wylex or Hager device only when tests name that device as failed.
- We quote fuse board replacement as its own job when the consumer unit has failed.
- We price emergency electrician attendance apart from fault finding.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWill you replace the RCD before finding the leak?
No. Testing comes before any part is removed. We name the leaking appliance, cable, fitting or device from those tests. A new RCD or RCBO is fitted only when the device itself has failed, and only when you want it done.
Will a new fuse board stop the RCD tripping?
A new fuse board stops repeat trips only when tests show the RCD or the consumer unit has failed. A leaking cable or appliance still opens the safety switch on a new board. We price fuse board replacement on its own after those tests.
What certificate do I get after an RCD repair?
You get a minor works certificate when we change the RCD, a cable or a fitting. That certificate lists the test results for the circuit we altered and shows our NAPIT registration. An EICR, an electrical installation condition report, inspects the whole installation and is booked as its own visit.
Do I still pay the hour if the fault is an appliance?
Yes. The hourly visit pays for the tests that name the appliance and for the cause we explain. We do not take the appliance apart. The RCD goes back on, with that appliance left unplugged, when the cables in the building test sound.
Will the repair happen in the same visit?
We repair the named fitting, cable or device in that visit when you want it done. A new fuse board is a different job with its own price. The RCD stays off when switching it on would put the leak back on the supply.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
Sources
- HSE: electrical faults, RCDs and competence
- BS 7671: IET Wiring Regulations (18th Edition, Amendment 2)
- Electrical Safety First: Homebuyer Electrical Safety
Updated 16 November 2026