RCD tripping when it rains
An RCD, the safety switch that cuts power when current leaks to earth, trips in the rain because water has made a path for that leak. Lighting Electrical tests those circuits in Peterborough and tells you what the readings show.
Calls answered 24/7
- 10 years trading
Why does the RCD trip when it rains?
Water on a socket, light or cable joint lets current leak to earth. The RCD trips on that leak. Where one RCD feeds the outside point and the rooms inside, those rooms go off together.
- Water in an outside socketWater in an outside socket leaks current from the live parts to the earthed metal box. The RCD trips on that leak. Rain gets in through a perished seal, a loose cable gland or a cover left open. A cable gland is the seal where the cable enters the socket.
- Rain inside an outside lightRain inside an outside light leaks from the lampholder to the metal body. The RCD trips on that leak. A failed gasket lets the water in. A lantern with a movement sensor trips the RCD each time the lantern comes on in the wet.
- Water at a gland on armoured cableWater at a loose gland runs onto the conductors of an armoured cable. Armoured cable has a metal sheath earthed at the gland. Rain bridges from a live conductor to that sheath. The RCD trips on the leak.
- Rain in a soffit downlightRain in a soffit downlight wets the connection behind the lamp. A soffit is the board under the eaves. The damp connection leaks current to earth. The RCD trips when that light is switched on.
- A failed RCDA failed RCD trips in damp weather while the circuit it guards is sound. Wear inside the device makes it react to moisture. The cable, the sockets and the lights test clear. The device itself is the fault.
What can I check when the RCD trips in the rain?
You check the closed fuse board, the outdoor plugs and outside fittings with water visible through the plastic. Covers stay shut. You do not touch the wiring.
- Outside plugs removed before a resetOutside plugs come out before any reset, including pumps, tools and extension leads. You switch off the indoor switch that feeds the outside socket when that switch is fitted. The RCD is reset once after that. A further trip leaves the leak in the socket, the light or the cable.
- The wider switch on the fuse boardThe RCD is the wider switch in the fuse board, also called the consumer unit. You read it with the cover shut. You push it up once after the outside plugs are out. You do that only while the board is cool, dry and quiet. You leave it down when it trips straight away.
- Water visible without taking a cover offYou look at the outside socket, the lantern and any enclosure for water behind the plastic. You also look for a drip from a cable gland. You keep your hands off the wet fitting. A stained ceiling shows rain has reached a joint above that room.
- One circuit dead or several rooms deadThe rooms that went off show which device tripped. An RCBO is a breaker and an RCD in one device for a single circuit, so only that circuit dies. A split load board has two RCDs. Several rooms dead together means the leak is on a circuit grouped with those rooms.
When should I book for an RCD that trips in the rain?
Book Now when the RCD will not stay on during or after rain. One reset is the limit while the fuse board is cool and dry. The next trip needs a test of the circuit.
- The RCD trips again after one resetThe leak is still on the circuit. Another reset heats the RCD and the cable. You leave that RCD off and Book Now. A second RCD keeps its rooms on.
- Water in a socket or a lanternWater you can see in an outside socket or a lantern is a path for the leak. You leave the RCD that feeds it switched off. You keep your hands off the wet plastic. The visit tests the seal, the gland and the cable.
- A hot board, a buzz or a burning smellA hot fuse board, a buzz or a smell of burning means a spark is jumping at a loose connection. That spark is arcing. You stop resetting. You leave the RCD off and Book Now.
What happens on a visit when rain trips the RCD?
We start at the fuse board and test the circuits that tripped before any part is changed. Any repair starts once you accept it. Circuits that stayed up remain on.
- Which rooms died and which switch trippedWe ask when the trips started and which rooms went off with the rain. We look at the fuse board with the cover on and note the RCD or RCBO that tripped. We note the outside socket, lantern or enclosure on that device.
- Insulation tests on the switched off circuitA dead test is a test with the circuit switched off. We switch the tripped circuit off and a tester shows there is no power before a cover comes off. An insulation test measures any leak between the conductors and earth. We test the next circuit on that RCD when the first reading is clear.
- The socket, lantern, gland and enclosureWe open the outside socket, lantern or enclosure that matches the low reading. We inspect the gland, the seal and the conductors for water. We name the failed gland, socket, joint, cable or RCD before we fit a new part. We check the earth bar, the metal strip that joins the earth wires, where an armoured cable lands on it.
- Repair of the part that failedWe fit the failed part once you accept that repair. Before we price the replacement we check the earthing, the bonding and the spare capacity in the supply. Earthing takes fault current to the ground. Bonding links metal pipes to that earth. We test the circuit again. We issue a minor works certificate where the circuit was altered.
What does a visit for an RCD rain trip cost?
Electrical Fault Finding & Repair is charged by the hour for an RCD that trips in the rain. The price covers the tests on the tripped circuits and the spoken diagnosis. Repair of the failed gland, socket, cable or device starts once you accept that repair. The price changes when more circuits need testing, when a part is replaced, or when a minor works certificate is needed. Fuse board replacement and an emergency electrician visit each have a separate price.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- Time rises when each circuit on the RCD needs its own insulation test rather than one wet socket.
- We charge for a replacement socket, gland, cable or device only when that item failed the test.
- We quote a failed RCD or a failed board as fuse board replacement, apart from the fault finding hour.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWhy does the whole house go off when it rains?
One RCD on the fuse board feeds the outside circuit together with a group of indoor circuits. A leak outside trips that RCD and the indoor rooms on it go off as well. A device that guards only the outside circuit leaves the other rooms on.
Will you change the RCD before you know the cause?
We do not change the RCD until the test names the failed part. We fit a new RCD only where the device itself has failed. The fitting goes ahead once you accept that repair.
Can you trace a trip that only happens in the rain?
An insulation test measures leakage with the circuit switched off. Rainwater left in a gland or a joint still shows on that test. We tell you the readings for each circuit on the RCD that tripped before any part is changed.
Will a new fuse board stop trips when it rains?
We fit a new fuse board when the test shows a failed RCD or a failed board. A wet cable still leaks on the new board. The new RCD trips on that leak.
Do I get a certificate when the circuit is repaired?
We issue a minor works certificate where the circuit was altered. The certificate carries the test results for the repaired circuit. Lighting Electrical is NAPIT registered.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.