Smell of burning from electrics

A smell of burning from the electrics means a connection is getting hot enough to char. Lighting Electrical in Peterborough switches that circuit off and tests for the hot joint.

Calls answered 24/7

  • 10 years trading

Why do electrics smell of burning?

Electrics smell of burning when a loose terminal or an overloaded cable heats the plastic around it. That heat cooks the insulation, the plastic coating on the copper.

  • A loose terminal that is arcingA terminal is the screw that clamps the copper in a socket or switch. When it loosens, the gap sparks. That spark is arcing, and it chars the plastic until the smell reaches the room. The breaker can stay up while this happens, because the current can still sit inside its rating.
  • Too much current in one cableA breaker is the switch in the fuse board that guards one circuit. Heaters and chargers stacked on one circuit push the cable harder than it is sized for. The insulation warms, and the smell shows at the first socket or at the board.
  • A hot joint inside the fuse boardThe fuse board, also called a consumer unit, feeds each circuit through its breakers. A loose neutral bar or a failing breaker heats inside the enclosure. The smell comes from the board while the fittings in the rooms still look ordinary.
  • A plug, flex or dimmer getting hotA kettle, heater or charger with a tired flex heats at the plug pins and browns the socket face. A dimmer that has failed cooks behind the switch in the same way. The fixed cable can be sound while that one device is the part that smells.
  • Rain in an outside light or socketRain that enters an outside light or a garden socket sits across the terminals. The wet joint heats and the plastic smells. That breaker stays off until the fitting is dried and tested.

What can I check when electrics smell of burning?

You can look, smell and use the breaker handles on a closed fuse board. Socket covers, appliance cases and the board cover all stay shut.

  • The spot where the smell is strongestWalk the rooms and note whether the smell sits at one socket, a light, the shower switch or the fuse board. That spot is the first place we test. A smell in one room means that circuit is the place to start.
  • Warm plastic, brown marks or a buzzLook at the socket face and the switch. Brown rings round the pin holes, a warm face or a buzz means arcing behind the plastic. Leave the plug out and leave the screws alone.
  • The breaker handles with the cover shutRead the labels through the closed cover. Put the breaker for the smelly room to off. If you cannot tell which breaker it is, turn the main switch on the front off. You do not open the cover and you do not touch the cables.
  • Plugs on the warm circuitPull the plugs on heaters, kettles and chargers fed from the warm socket. If the smell fades, that appliance is the part that was heating. If the smell stays, the fixed wiring still needs a test.

When should I book for a burning smell?

Book Now when a socket, a switch, a light or the fuse board smells of hot plastic. A new lamp that smells for a few seconds and then runs cool is not a charred joint.

  • A smell that stays with the plugs outThe portable appliances are unplugged and the smell is still at the socket or the board. The hot joint is in the fixed wiring or the fuse board. Leave that breaker off.
  • Scorch marks, heat or a buzzBrown plastic or a buzzing fitting means the joint is arcing now. Leaving that circuit on lets the char travel along the cable. Book Now and keep the breaker off.
  • A fuse board that smells or feels hotA smell from the board, or a cover that is hot, means a connection inside is failing. Use the main switch on the front if you can do that without touching a cable. The cover stays on.
  • A breaker that opened with the smellThe breaker tripped at the same time as the smell, so the cable or the device overheated. Putting it back on sends current through the damaged joint. Leave that breaker off.

What happens on a burning smell visit?

We make the smelly circuit dead, test the hot joint and name the failed part before any fitting is changed. Circuits that are cool and quiet stay on.

  • The circuit that smellsWe ask which room smells and which breaker you moved. We prove the circuit is dead with a tester before a screw comes out. The other breakers stay as they are when those circuits are cool and quiet.
  • Tests on the hot jointWe open only the socket, switch or fuse board that smells. With the circuit dead we check for loose copper, conductors touching, and current leaking to earth. Earth is the safety path that carries a fault away from you.
  • Earthing, bonding and the supplyEarthing is the path that lets a breaker open on a fault. Bonding is the link that joins metal pipes to that earth. We check both on the visit, and we check the supply can carry the load before we price the repair.
  • The failed part and the certificateWe change the socket, switch, breaker or cable when you accept that repair. We test the circuit again afterwards. If the circuit was altered we write a minor works certificate showing our NAPIT registration. If the board has burnt we leave it switched off and price fuse board replacement as the next job.

What does a burning smell visit cost?

The price covers our time on the visit, tests on the circuit that smells, and making that circuit safe to leave. The repair of the failed socket, switch or breaker starts when you accept that part. Fetching a replacement part, writing a minor works certificate, or pricing fuse board replacement as its own job changes the price. Emergency electrician attendance is charged as that job.

From £90 an hour

Included in the call-out

  • Attendance at the property in Peterborough or a nearby Essex town
  • Isolation of the failed circuit, fitting or board
  • Fault finding on the circuit that has gone down
  • Temporary making safe so the rest of the installation can be used where that is possible
  • A written note of what failed and what work should follow

Not included automatically

  • A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
  • Parts we do not carry in the van, which we price in writing before we fit them
  • Work on another trade such as gas, plumbing or structural fabric

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • A single scorched socket takes less time than a fuse board with several warm breakers.
  • A socket, switch or breaker from Hager, Wylex, Contactum, BG Electrical or MK Electric goes in only after the test shows it has failed.
  • A burnt fuse board is written up as a later job, separate from the visit that made the circuit safe.

View the emergency call-out cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about a smell of burning

Still have a question?

Should I leave the breaker on if the smell is faint?

No. Switch that breaker off and unplug what you can on that circuit. A faint smell of hot plastic still means a joint is heating. We test the circuit before it is switched on again.

Will a new fuse board stop the burning smell?

A new fuse board removes the smell when the burnt part is the board or a breaker in it. A charred socket or a damaged flex still smells after a board change. We name the failed part before any board is changed.

What paperwork do I get after the repair?

If we change a socket, a switch, a breaker or a length of cable, you get a minor works certificate. The certificate lists the test results for that job and our NAPIT registration. An Electrical Installation Condition Report, an EICR, is a separate inspection of the whole installation.

Can I reset the breaker once the smell fades?

One reset is reasonable when the smell has gone, the plastic is cool and the board is quiet. If the breaker opens again, or the smell comes back, leave it off. Resetting it again puts heat back on the damaged joint.

Do you repair the burnt part on the same visit?

We repair the socket, switch or breaker on the visit when you accept that part and the part is with us. If the part has to be fetched, or the fuse board has burnt, we leave the circuit off and write a price for the next job. Circuits that test sound stay in use.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (1)