Smoke coming from a socket
Smoke from a plug socket means a connection is burning and that circuit has to come off. Lighting Electrical in Peterborough isolates the circuit and names the burnt socket or plug.
Calls answered 24/7
- 10 years trading
Why does a plug socket smoke?
A plug socket smokes when a connection runs so hot that the plastic chars. The heat is in the socket, the plug, or the cable just behind the face.
- A loose terminalA terminal is the screw that clamps the copper inside the socket. When that screw is loose the wire sparks. The spark is called arcing, and the heat chars the plastic until smoke leaves the face.
- Worn grips on the plug pinsThe grips are the metal springs that hold the plug pins. Tired springs leave a gap. Current jumps the gap, the pin heats, and smoke comes out of the pin holes.
- Too much load in one socketA heater, a kettle and an extension lead in one socket draw more current than the contacts can carry. The face can char while the breaker is still up, because a poor contact heats before the current reaches the breaker rating.
- A damaged plug in a sound socketBent pins or a cracked plug make a poor connection even in a sound socket. The plug smokes first and scorches the face around the pins. The socket then needs a test because that heat can spread into the terminals.
- Cable cooked behind the faceHeat from an earlier overload cooks the insulation where the cable enters the socket. The next time the socket is used, that damaged insulation smokes. The fault sits in the cable end as well as the plastic face.
What can I check safely if a socket smokes?
You can switch the circuit off at the fuse board and look from a distance, with every cover left on. You do not open the socket, the plug or the fuse board.
- Switch the circuit off at the fuse boardThe fuse board is the box of switches for the house. Use the breaker for the sockets, or the main switch if you cannot tell which breaker it is. A breaker is the switch that guards one circuit. Leave the cover shut.
- Leave a hot or smoking plug alonePull a plug only when the plastic is cool and the smoke has stopped. If the face is hot, melted or still smoking, leave the plug in. Do not open the socket, do not open the plug, and do not put water on it.
- Notice which other points went offAfter the circuit is off, see whether nearby sockets died with it. A light that still works is on a different circuit. Do not switch the socket breaker back on to test your idea.
- Brown marks from a step backLook for brown stains, soft plastic or a burning smell at that socket. Leave any other warm socket unused. Keep the fuse board cover on.
When should I book for smoke from a socket?
Book Now if a socket has smoked, sparked or smelt of burning. Keep that circuit switched off at the fuse board.
- Smoke, sparks or a burning smellSmoke or a spark from a socket means a connection is already burning. The circuit stays off after you have switched it. The socket stays unused until we test it.
- A hot or melted socket faceA face that is too hot to touch, or plastic that has gone brown or soft, has damaged contacts. Leave the screws where they are. Book Now with that breaker left off.
- The socket breaker is already offA smoking socket can open its breaker, or the RCD that protects it. An RCD is a safety switch that turns off when current leaks to earth. Leave that switch off and Book Now.
What happens on a visit for a smoking socket?
We switch the smoking circuit off, test it, and name the burnt part before we replace anything. We leave the other breakers as they are.
- Make the smoking circuit deadWe ask which socket smoked and whether a plug was in it. If that circuit is still on, we switch it off at the fuse board. A tester confirms the cable is dead before any screw comes out.
- Test the socket, the plug and the cableWith the circuit dead we measure whether the cable is shorted, open or leaking to earth. Earth is the path that carries fault current away from you. Those readings separate a burnt socket, a scorched plug and a damaged cable.
- Open only the socket that smokedWe remove the face on the socket that smoked and inspect the terminals and the cable ends. A sound socket on the same circuit stays closed. We tell you what burnt before a part is replaced.
- Replace the burnt part and test againThe new socket, cable end or plug is fitted after you accept it. We test the circuit again and record the results. A minor works certificate covers a change to the circuit and carries our NAPIT registration. The breaker stays off if the cable is still unsafe.
What does a smoking socket visit cost?
The price covers our attendance, switching off the smoking circuit, and the tests that name the burnt socket, plug or cable. A new socket, extra cable, more time on several scorched sockets, or a minor works certificate changes the price. A fuse board replacement is quoted in writing before that work starts.
From £90 an hour
Included in the call-out
- Attendance at the property in Peterborough or a nearby Essex town
- Isolation of the failed circuit, fitting or board
- Fault finding on the circuit that has gone down
- Temporary making safe so the rest of the installation can be used where that is possible
- A written note of what failed and what work should follow
Not included automatically
- A full house rewire or a planned consumer unit replacement on the same visit unless already quoted
- Parts we do not carry in the van, which we price in writing before we fit them
- Work on another trade such as gas, plumbing or structural fabric
Ways to pay


- Pay by bank
- Bank transfer
- One burnt face is a shorter test than several sockets with scorched terminals on the same circuit.
- A socket or cable from Hager, Wylex, Contactum, BG Electrical or MK Electric is fitted only when the tests show it has failed.
- We quote a fuse board replacement in writing before any board work starts, and only after the tests show the board has failed.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan the other sockets stay on?
Yes. We switch off the circuit that smoked and leave the other breakers as they are. That circuit goes back on only when the tests show it is safe to leave live.
Should I pull the plug out of a smoking socket?
Pull the plug only when the face is cool and the smoke has stopped. If the plastic is hot, melted or still smoking, switch the circuit off at the fuse board and leave the plug in place.
Will you replace the socket on the same visit?
We name the burnt socket, plug or cable before we fit a part. The replacement goes ahead on the visit once you accept it. A fuse board replacement is quoted in writing before that work starts.
What paperwork do I get after the repair?
A minor works certificate records the tests when we change the socket or the cable, and it carries our NAPIT registration. If we only make the circuit safe and change nothing, we write down the readings and the burnt part.
Was the smoke from the plug or the socket?
A scorched plug can burn a sound socket, and a worn socket can burn a sound plug. We test the plug and the socket. We replace only the part the test shows has failed.
Related problems
- Brown marks on a socket or plugBrown marks on a socket or plug mean the connection has overheated, so that circuit stays off until it is tested.
- Burning plastic smell from electricsA burning plastic smell means the insulation on a live joint is getting hot, so that circuit stays switched off until it is tested.
- Burning smell from a socketA burning smell from a socket means a connection is overheating and that circuit should stay off until it is tested.
- Burning smell from the fuse boxA burning smell at the fuse box means a connection or device is overheating, so that circuit stays off until it is tested.
- Electric shock from a light switchA shock from a light switch means the switch face is carrying current and that lighting circuit should be isolated.
- Electric shock from the showerA shock from the shower means current is on the water, the case or the taps, so that circuit stays off until it is tested.
Sources
- HSE: Electrical Safety at Work
- Electrical Safety First: Safety Guidance
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 16 November 2026