Socket not working after a power cut

A socket that stays dead after a power cut means that circuit opened when the supply returned. Lighting Electrical in Peterborough tests the socket circuit and names the part that failed.

Calls answered 24/7

  • 10 years trading

Why is a socket dead after a power cut?

The supply is back, and this socket circuit opened as the power returned. A breaker, a leak to earth or a damaged connection is what keeps the socket dead.

  • Appliances starting togetherWhen the supply returns, heaters and motors start at the same moment. That rush of current is called inrush. Inrush opens the socket breaker, the switch on the fuse board that guards the socket circuit. The sockets on that breaker stay dead.
  • An appliance leaking to earthEarth is the safety path that carries a fault away from you. A fridge, heater or extension damaged in the cut leaks current to earth the moment power returns. An RCD, the switch that opens on that leak, drops and will not stay up.
  • A loose socket connectionA terminal that was already loose arcs when voltage comes back. Arcing is a spark across a poor joint. The socket goes dead, and sockets further along the same cable can go dead with it.
  • A surge through the circuitA spike as the supply returns can puncture insulation or weld contacts inside a socket. A surge protective device, the part that absorbs that spike, can fail at the same time and open its own switch.
  • One break in a ringA ring runs from the fuse board through the sockets and back. If one joint opens during the cut, sockets on one side of that joint stay dead. Sockets on the other side can still work.

What can you check safely after the power returns?

You can read the fuse board, unplug appliances and try a lamp you already trust. The socket fronts stay on and the board cover stays shut.

  • Switches you can see on the fuse boardLook through the closed cover. A socket breaker sitting down, while other breakers are up, is the circuit that opened. Reset it once only if the board feels cool, makes no noise and smells normal.
  • Appliances that were plugged inUnplug kettles, heaters, chargers and extension leads on the dead sockets. Reset the socket breaker once. If it holds, plug each item back until one of them opens it again. That item stays unplugged.
  • A lamp from a live socketTake a lamp that already lights in another room and plug it into the dead socket. If the lamp stays dark, that socket has no supply. If the lamp lights, the appliance you removed is the part that failed.
  • How many sockets stayed deadTry a socket in the same room and one in another room. Every socket dead points to the breaker or the cable leaving the board. One socket dead points to that outlet or a short branch off the circuit.

When should you book for a socket dead after a power cut?

Book Now when a single reset will not hold, or when a socket or the fuse board is hot, noisy or smelling of burning.

  • The breaker will not stay upWith every plug pulled, the socket breaker still drops straight away. The fault remains in the wiring, a socket or the device that protects it. Leave that breaker off. Repeated resets warm the terminals.
  • Heat, noise or a burning smellA warm faceplate, a buzz or brown marks around the pin holes means a joint is arcing. Switch that circuit off at the breaker handle. Keep the socket screws in place.
  • Some sockets back and some still deadPower at part of the circuit and none at the rest means a joint opened when the supply returned. Those sockets need a test before the open joint overheats.
  • Water in an outside socketRain during the cut can sit in an outdoor socket and leak current to earth. The RCD opens and will not hold. Leave that circuit off and keep your hands off the wet plastic.

What happens on a visit for a socket dead after a power cut?

We start at the fuse board, test the socket circuit while it is off, and name the failed part before anything is changed.

  • What you noticed when the supply returnedWe ask which sockets stayed dead, which came back, and what was plugged in during the cut. We read the breakers with you. We leave the cover on until our tester confirms the circuit is dead.
  • Tests with the socket circuit offWe isolate the circuit at its breaker. With the breaker off we measure continuity, which tells us if the copper path is complete, and insulation, which tells us if the wires are leaking. Those readings point to the breaker, one socket, a joint or a run of cable.
  • The failed part named before a repairWe tell you the failed socket, joint, cable, breaker or appliance before a part is changed. We check the earth path, the bonds on metal pipes and whether the supply can carry another load before we write any further price.
  • The repair and the paperworkThe repair goes ahead after you accept it. We test the circuit again. Where the repair alters the circuit, a minor works certificate records the tests and shows our NAPIT registration. If the circuit cannot be left live, its breaker stays off.

What does a socket fault after a power cut cost?

Electrical Fault Finding & Repair is charged by the hour. That hour covers tests on the socket that stayed dead, the diagnosis we speak to you, and the start of the repair once you accept it. A replacement part, a minor works certificate or more time on the circuit changes the price. Emergency electrician attendance is priced as its own job.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • A single tripped breaker takes less time than an open joint that has killed several sockets.
  • Parts from Hager, Wylex, Contactum, BG Electrical or MK Electric go on the bill only after the tests show that part has failed.
  • A failed fuse board is quoted on its own, apart from the hourly fault finding.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about a socket dead after a power cut

Still have a question?

Why did the lights come back when the socket did not?

The lighting breaker and the socket breaker are separate switches. Power returning can open the socket switch and leave the lighting switch up. We test the dead socket circuit and tell you which part opened.

Should I reset the breaker more than once?

Unplug the appliances and try a single reset while the board is cool and quiet, with no smell of burning. Stop if the breaker opens again. We find the cause with the circuit off.

Will you change the socket before you know the cause?

No. The tests come first, and we name the joint, socket, cable or device that failed. Nothing is changed until you accept the repair. A sound socket stays where it is.

Do I get a certificate after this repair?

A minor works certificate follows when we alter the circuit. It records the tests for the finished repair and our NAPIT registration. An EICR, the full inspection report, is a different job if you want the whole installation checked.

Can a power cut damage the appliance in the socket?

Yes. A spike or a rush of current can leave a heater, fridge or charger leaking to earth. We test with that appliance unplugged. If the leak is in the appliance, the sockets go back on and that appliance stays out.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)