Sockets not working but lights are fine

Sockets with no power while the lights stay on mean the socket circuit has failed and the lighting circuit has not. Lighting Electrical in Peterborough tests that circuit at the fuse board and at the sockets.

Calls answered 24/7

  • 10 years trading

Why do sockets stop working while the lights stay on?

Sockets and lights are wired as separate circuits, so a fault on the sockets leaves the lights on. The lighting breaker stays up because that circuit is not the one with the fault.

  • A tripped breaker on the socketsA breaker is the switch on the fuse board that guards one circuit. The socket breaker trips on an overload or a short, and the sockets on it go dead. The lighting breaker is a separate switch, so the lights stay lit.
  • An RCD that covers only the socketsAn RCD is a safety switch that turns off when current leaks to earth. On a split load board the sockets sit on one RCD and the lights sit on another. Current leaking from a socket drops the socket RCD and the lights stay on.
  • An RCBO on the socket circuitAn RCBO is one device that acts as both a breaker and an RCD for a single circuit. When the socket RCBO trips, only those sockets go dead. Lights on a different device stay on.
  • A break in the socket cableA ring final circuit leaves the fuse board, passes through the sockets and returns. A radial leaves the board and stops at the last socket. A loose terminal or a broken wire opens either cable. The lights stay on because they use their own cable.
  • Burnt terminals inside a socketA hot plug scorches the terminals inside a socket. That outlet goes dead. On a ring, a second damaged terminal splits the loop and more sockets go dead with the lights still on.
  • A faulty appliance in a socketA fault inside a kettle, heater, fridge or extension leaks current to earth or overloads the socket circuit. The socket breaker or the socket RCD trips. The lights stay on because they do not share that switch.

What can you check safely with the covers on?

You can check the fuse board, the plugs and a known lamp without opening a socket or the board.

  • The switches on the fuse boardYou leave the fuse board cover shut. The socket breaker sits down and the lighting breaker stays up when only the sockets have tripped. One reset is reasonable if the board is cool, quiet and free of any burning smell.
  • Plugs pulled from the dead socketsYou unplug every appliance on the dead sockets, including extension leads. You reset the socket switch once. If it holds and a lamp works, you plug each appliance back in turn until one of them trips the switch again.
  • A lamp you already know worksYou plug that lamp into a dead socket. The lamp staying off means the socket has no power. The lamp lighting means the first appliance is the failed part.
  • Whether one room or every room is deadYou try a socket in the kitchen, one in the living room and one upstairs. Every socket dead points to the breaker, the RCD or the cable leaving the board. One room dead points to a single socket or a spur, which is a branch off the circuit to one point.

When should you book for dead sockets with working lights?

Book Now if one reset fails to hold, or if a socket or the fuse board is hot, noisy or smelling of burning.

  • The socket switch drops againThe appliances are unplugged and the switch still opens at once. The fault sits in the cable, a socket or the protective device. Further resets heat the terminals, so the circuit stays off until it is tested.
  • Heat, a buzz or a burning smellA warm socket, a buzz or brown marks mean the terminals are arcing. Arcing is a spark across a loose joint, and it chars the cable behind the socket front. You leave that circuit switched off.
  • Only some of the sockets workPower at some sockets and none at others means the ring is open at a joint. The lights still work on their own circuit. The open joint needs a test before those terminals overheat.
  • Water on a socket or in a floodA leak, a flood or rain in an outside socket lets current leak to earth. The socket RCD trips and the lights stay on. You leave the socket switch off and keep your hands away from the wet plastic.

What happens on a visit for dead sockets?

We start at the fuse board and name the failed part before any socket or cable is changed. The lighting circuit stays on while the socket circuit is isolated for test.

  • Which sockets died and which switch droppedWe ask which rooms still have lights and which sockets are dead. We look at the fuse board with you and note the switch that has opened. We remove no screw until a tester shows the circuit is dead.
  • Readings around the socket circuitA continuity test checks whether the copper still connects all the way round the circuit. We run that test with the socket circuit isolated. An insulation test then checks for leaking current between the conductors. The two results separate a breaker, a socket, a joint and a length of cable.
  • Earthing and spare capacity before a priceWe tell you what failed before any part is changed. Earthing, the safe path for fault current, is checked on the visit. Bonding, the link from metal pipes to that earth, is checked as well. We also check that the supply has room for the load before we write any further price.
  • The repair and the certificateThe repair of that socket, joint, cable or device goes ahead after you accept it. We test the circuit again after the work. Where the circuit was altered, we issue a minor works certificate under our NAPIT registration. We leave the socket switch off when the circuit is unsafe to put back on, and the lights stay on.

What does finding a dead socket circuit cost?

We charge fault finding and repair by the hour. The price covers tests on the dead socket circuit, the diagnosis we give you, and the repair after you accept it. A longer test, a replacement part, or a minor works certificate changes the price. Emergency electrician attendance is priced separately.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • Testing an open ring at several sockets takes longer than checking one appliance that trips the breaker.
  • A socket, breaker or cable from Hager, Wylex, Contactum, BG Electrical or MK Electric is added only when the tests show it has failed.
  • Fuse board replacement is written as its own job when the tests show the board has failed.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about dead sockets and working lights

Still have a question?

Why do my lights work when the sockets do not?

The lights leave the fuse board on a different breaker from the sockets. A fault on the socket breaker, the socket RCD or the socket cable does not open the lighting breaker. We test the socket side and tell you which part has cut the power.

Should I reset the socket breaker once?

One reset is reasonable after you unplug every appliance, and only while the fuse board stays cool and quiet. If the breaker drops straight away, leave it off. We test the circuit instead of resetting it again.

Will you replace sockets before finding the fault?

No. We test the circuit and name the failed socket, joint, cable or device first. The repair starts only after you accept it. A socket that tests sound stays on the wall.

Do I get paperwork when the socket circuit is repaired?

We issue a minor works certificate when the repair changes the circuit. It records the tests for the work we finished, under our NAPIT registration. An Electrical Installation Condition Report, called an EICR, is a separate inspection of the whole installation.

Will a new fuse board bring the sockets back?

A new fuse board brings the sockets back only when the tests show the board has failed. A broken cable or a burnt socket still leaves the sockets dead on a new board. Fuse board replacement is priced on its own after those tests.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)