Storage heater not charging overnight
A storage heater stays cold in the morning when the night supply or the heater input has failed. Lighting Electrical in Peterborough tests both and names the part that stopped the charge.
Calls answered 24/7
- 10 years trading
Why is my storage heater not charging overnight?
The heater misses its charge because the night electricity supply stayed off, or because it could not store that heat in its internal bricks.
- The night supply stayed offThe night supply is a separate feed that a time switch or the meter turns on for the charge period. Economy 7 is one tariff that does this. If that switch never closes, every storage heater in the home stays cold.
- The storage heater breaker has openedA breaker is the switch in the fuse board that opens on too much current or on a leak to earth. Earth is the safety path for fault current. With the storage heater breaker down, the charge stops and the lights stay on.
- The input dial is low or has failedThe input dial sets how much heat the bricks store overnight. At the bottom of its range the element stays off. The output dial only releases heat later in the day, so it cannot start the charge.
- The safety cut out or the element has openedThe element is the wire that heats the bricks. A safety cut out opens if the heater gets too hot, and it stays open until it is reset or replaced. That one heater then stays cold while the others still charge.
- A bad joint at the heater switchThe isolator is the switch on the wall next to the heater. A loose terminal there stops power to that heater only. A warm switch, a buzz or brown marks means the joint is overheating.
What can I check on a cold storage heater?
You can check the dials, the wall switch and the fuse board without taking a cover off. You leave the heater casing shut.
- Whether the casing is warm or coldIn the morning, before you raise the output, put the back of your hand near the top grille. Warm air means the bricks took a charge. Cold air means the charge did not happen.
- The input dial against the output dialTurn the input up if it sits at the bottom, then wait for the next night. Leave the output low overnight so you can judge the casing in the morning. A high output does not put heat into the bricks.
- The wall switch and the other heatersThe isolator beside the heater should be on. If several heaters are cold together, the night supply did not switch. If only one is cold, the fault is in that heater or its own switch.
- The breaker behind a closed coverRead the names on the breakers through the fuse board cover. The switch for the storage heaters or the night supply should be up. Reset it once if the board is cool and silent. If it opens again, leave it down.
When should I book for a storage heater not charging?
Book Now when the casing is still cold after a night with the input turned up and the wall switch on.
- The heater is cold after a full nightThe input was already high and the isolator was on. Another night on the same settings will not fill the bricks. The night supply or the heater needs a test.
- The breaker drops out againOne reset did not hold. The fault is still on the circuit. Another reset heats the breaker and the cable, so leave that switch down.
- The switch is hot, noisy or smells of burningHeat, a buzz or a burning smell at the isolator or the fuse board means a joint is failing. Use the breaker handle to switch that circuit off. Leave every cover screw where it is.
What happens on a visit for a cold storage heater?
We test the night supply and the cold heater in order, and we say which part stopped the charge before we fit anything. Any repair waits until you accept it.
- What failed and whenWe ask which heaters are cold, what the dials were set to, and whether the wall switches were on. We look at the night supply breaker with you. The fuse board front stays on for that look.
- Measurements on the night feedWe switch the storage heater circuit off at the breaker. We measure the feed at the board and at the isolator. The readings separate a time switch, a meter switch, a breaker, a cable and the heater.
- Input, cut out and elementWith the circuit still off we test the input control, the safety cut out and the element at the heater terminals. We name the failed part before we replace it. A heater that passes stays shut.
- Repair, tests and paperworkWe fit the failed control, connection, breaker or element after you accept the repair. We retest the circuit. A minor works certificate records the alteration and our NAPIT registration. Earthing is the fault path back to the board. Bonding links metal pipes to that earth. We check both, and whether the supply has room for the heater load, before a later price.
What does storage heater fault finding cost?
We charge Electrical Fault Finding & Repair for the time on site. That time covers the tests on the night supply and the cold heater, the diagnosis we speak to you, and the repair after you accept it. Tracing a night supply that feeds several heaters takes longer than testing one cold heater. A part, a minor works certificate or a separate fuse board replacement changes the price.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- A control, an element, a breaker or a length of cable is added only when the tests show it has failed.
- Fuse board replacement is written as its own job when the night supply breaker or the board has failed.
- Emergency electrician work is charged separately from Electrical Fault Finding & Repair.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWill you replace my storage heater straight away?
No. We test the night supply, the input, the cut out and the element, and we name the failed part first. The repair of that part starts after you accept it. A heater that tests sound stays in place.
Does a high output setting mean the heater should be hot?
No. The output setting only lets stored heat into the room. The input setting decides how much heat the bricks take overnight. A cold casing with the input already high means the charge did not go in.
Will a new fuse board make the storage heater charge?
Only if the tests show the night supply breaker or the fuse board has failed. A failed element or a failed input still leaves the heater cold on a new board. We price a fuse board replacement on its own after the tests.
What paperwork do I get after the repair?
A minor works certificate records the alteration and the test results, and it carries our NAPIT registration. You receive that certificate when the repair changes the circuit. If the visit ends with the circuit switched off and no new part fitted, we still tell you the failed part.
Should I try another night before I book?
Try one more night only if you have just turned the input up or just switched the isolator on. If those were already set and the casing is cold, Book Now. Leave a breaker that will not hold in the off position.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
Sources
- Energy Saving Trust: Heating Your Home
- Electrical Safety First: Safety Guidance
- NICEIC: Householder Guidance
Updated 16 November 2026