Storage heater not heating
A storage heater that stays cold has missed its charge on its own circuit. Lighting Electrical tests that circuit from the fuse board to the heater and names the failed part.
Calls answered 24/7
- 10 years trading
Why is my storage heater not heating?
A storage heater stays cold when the off peak supply never reaches the bricks, or the stored heat never leaves the case. The fault is on the storage heater circuit.
- The off peak supply never came onStorage heaters charge while a separate off peak supply is live, often through the night. A failed time switch or contactor leaves that supply dead. The bricks never heat, so the room stays cold all day.
- The storage heater breaker has openedThe storage heaters sit on their own breaker in the fuse board. A breaker is the switch that opens when a circuit overloads or leaks to earth. Earth is the safe path for fault current. An open breaker stops the charge to every heater on that circuit.
- The input control stored no heatThe input control sets how strongly the elements heat the bricks. A control left at the bottom, or a control that has failed, stores little or nothing. The output control cannot warm the room if the bricks were never charged.
- The output flap held the heat inThe output control opens a flap so stored heat can leave the case. A flap left shut keeps the bricks hot and the room cold. The charge circuit can still be sound when only the flap is shut.
- One heater cable or element has failedEach heater has an isolator, the wall switch that disconnects it, and an element that warms the bricks. A loose joint at the isolator or an open element leaves that heater cold. Heaters on the same circuit can still charge.
What can I check on a cold storage heater?
You can check the knobs, the wall switch and the closed fuse board. You do not open the heater, and you do not touch the wiring.
- Whether the case is warm in the morningPut the back of your hand near the top grille in the morning. A warm case means the bricks took a charge. A stone cold case means the off peak supply, the breaker or the input did not heat them.
- The input and output knobsTurn the input knob to a high setting before the off peak hours. Open the output during the day. Leave the heater case screwed shut. The knobs are the only controls you need to move.
- The wall switch beside the heaterLook at the isolator beside the heater and see that it is on. Leave its screws in place. A switch sitting off stops that heater and leaves the others alone.
- The storage heater breaker, cover shutFind the breaker for the storage heaters and read it through the closed fuse board cover. One reset is reasonable when the board is cool and makes no noise or smell. If the switch opens again at once, leave that breaker off.
When should I book for a storage heater not heating?
Book Now if the heater is still cold after the off peak hours, or if a switch is hot, buzzing or smelling of burning.
- The case is still cold after a chargeThe input was turned up, the wall switch was on, and the case is still cold after the off peak hours. The fault is in the supply, the breaker, the cable or the heater. Book Now so we can test that circuit.
- The breaker will not stay onThe storage heater breaker opens again as soon as you reset it. Another reset heats the switch and the cable. Leave the breaker off and Book Now.
- Heat, a buzz or a burning smellA warm wall switch, a buzz or a burning smell means a joint is failing. Use the breaker handle to switch that circuit off. Do not touch the heater fixings or open the fuse board.
- One heater is cold and the others are warmThe other heaters charged, so the off peak supply is present. The cold heater has a failed isolator, cable or element. Book Now before that joint overheats.
What happens on a storage heater visit?
We test the storage heater circuit from the fuse board and name the failed part before any repair. The other circuits stay on.
- Which heater missed its chargeWe ask which heater is cold, whether the case was warm in the morning, and where you set the input. We read the storage heater breaker with you. The fuse board cover stays shut until a tester shows that circuit is dead.
- Tests on the storage heater circuitWe switch off the storage heater circuit at its breaker. We test whether the off peak supply reaches the isolator. We test the element circuit, the wiring and element that warm the bricks. The readings separate a breaker, a cable, an isolator and a failed heater.
- The failed part named before a priceWe tell you what failed before any part is changed. We test earthing and bonding on the visit. Earthing is the safe path for fault current. Bonding joins metal pipes to the fuse board. We also check that the supply can carry the heater load before any further price.
- Repair of that circuit and the certificateThe repair of the failed breaker, cable or isolator on the storage heater circuit goes ahead after you accept it. We test the circuit again. A minor works certificate records a change to that circuit under our NAPIT registration. We leave the circuit off when it is unsafe to switch back on.
What does a storage heater fault visit cost?
The hours spent on the storage heater circuit set the price. Those hours cover the tests, the spoken diagnosis, and the repair of the failed breaker, cable or isolator once you accept it. A bank of heaters, a replacement part, or a minor works certificate changes the price. Emergency electrician work is priced separately from Electrical Fault Finding & Repair.
From £75 an hour
Included when agreed
- Testing at the board and along the failed circuit until the cause is named
- A spoken diagnosis before any part is swapped
- Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
- Making the circuit safe if it cannot be left live that day
- A minor works certificate when the repair needs one
Not included automatically
- A full house rewire or a new consumer unit as the first step
- Solar, battery, EV charger or forklift charger work
- Guesswork replacement of parts that have not failed
Ways to pay


- Pay by bank
- Bank transfer
- Testing the off peak supply to a whole bank of heaters takes longer than testing one cold heater.
- A breaker, a length of cable or an isolator is fitted only after the tests show it has failed.
- Fuse board replacement is priced on its own when the storage heater breaker or the board has failed.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowWhy is the room cold when the storage heater was left on?
The input control charges the bricks only while the off peak supply is live. The output control lets that heat out later. A low input or a missed off peak period leaves the bricks cold, so an open output still cannot warm the room.
Will you replace parts before you find the fault?
No. We test the storage heater circuit and name the failed breaker, cable, isolator or heater first. The repair of that circuit starts only after you accept it.
What if every storage heater is cold?
Every cold heater points to the off peak supply or the breaker that feeds them all. One cold heater beside warm heaters points to that heater's isolator, cable or element. We test the storage heater circuit in both cases.
Do I get a certificate after the repair?
A minor works certificate follows when the repair changes the storage heater circuit. It records the tests for that work and our NAPIT registration. If we change nothing and leave the circuit off, you still get the readings and the named fault.
Can the rest of the house stay on while you test?
Yes. We switch off only the storage heater circuit and leave the lights and sockets on. That circuit goes back on after a repair you have accepted, and it stays off if it cannot be left live.
Related problems
- Automatic gate not openingA gate that will not move has lost its supply, its safety beam or its motor control, so the outdoor circuit needs a test.
- Buzzing sound in the wallA buzz inside a wall is a loose joint, a dimmer or a damaged cable on that circuit.
- Circuit breaker keeps trippingThe breaker keeps tripping because a fault is still on the circuit, in an appliance, a cable, a joint or the protective device.
- Consumer unit tripping with nothing plugged inThe consumer unit trips with nothing plugged in because fixed wiring or the safety switch is sending current to earth.
- Downstairs circuit keeps trippingThe downstairs breaker or RCD opens because a socket, light, cable or appliance on that floor is leaking or overloaded.
- Driveway lights not workingDriveway lights go dark when the outdoor circuit, a sensor or a lantern fails, while rooms on another breaker stay lit.
Sources
- Energy Saving Trust: Heating Your Home
- Electrical Safety First: Safety Guidance
- NICEIC: Householder Guidance
Updated 16 November 2026