Two way light switch not working

A two way light switch fails when either switch will not turn the same light on or off. Lighting Electrical in Peterborough tests both switches and the cable between them, then names the failed part.

Calls answered 24/7

  • 10 years trading

Why does a two way light switch stop working?

A two way pair fails when one switch, the wires linking the switches, or the light itself no longer completes the circuit. The pair is two switches for one light, usually the hall and the landing.

  • A worn switch in the pairThe contacts inside one switch wear until they no longer change over. The second switch may still work in one position only. The light then stays on, or stays off, when you press the worn switch.
  • A loose strapper between the switchesStrappers are the two wires that run between the switches and carry the changeover. A loose terminal at either end opens that link. The light then answers one switch only, or answers neither.
  • A spent lamp or loose lampholderA spent lamp or a loose lampholder makes both switches look dead. The switches can be sound while the fitting has failed. Other lights on the same breaker still work, which separates one fitting from a dead circuit.
  • The lighting breaker has openedThe lighting breaker is the switch in the fuse board that feeds this circuit. When it opens, both switches are dead because the circuit has no power. Lights on a different breaker stay on.
  • A loose joint in the ceiling roseThe ceiling rose is the base where the pendant flex meets the fixed cables. A loose connector there opens the live feed to the pair. Both switches do nothing while another light on the same breaker still works.

What can I check on a two way switch safely?

You can press both switches, fit a lamp you already know works, and read the lighting breaker through the closed fuse board cover.

  • Both switches in turnPress the hall switch, then the landing switch, then each one again. Note which switch still changes the light and which does nothing. The screws in both switch fronts stay in.
  • A lamp that already worksWith the light switched off, fit a lamp that already lights in another room. If that lamp stays dark from both switches, the fault sits in the switches or the cable. If it lights, the old lamp had failed.
  • The lighting breaker behind the coverRead the breaker marked lights through the closed fuse board cover. A breaker sitting down has opened. One reset is reasonable if the board is cool and quiet and has no burning smell. If it opens again, leave it down.
  • A warm, noisy or marked switchA warm switch front, a crackle or brown marks means a joint behind the front is failing. Stop using that switch. Keep the screws in and leave the lighting breaker off if the board smells of burning as well.

When should I book for a two way switch fault?

Book Now when one switch no longer controls the light, a reset will not hold, or a switch is hot, crackling or smelling of burning.

  • One switch no longer changes the lightBoth switches have been tried with a lamp that works. One switch still will not turn the light on or off. That switch or the strappers need a test before the joint overheats.
  • The lighting breaker will not holdThe lighting breaker opens again after the one reset. Further resets heat the breaker and the cable. The circuit stays off until it is tested.
  • Heat, a crackle or a burning smellHeat, a crackle or a burning smell at a switch means the contacts are arcing. Arcing is a spark jumping a loose joint. Use the breaker handle to switch the lights off and leave the switch front closed.

What happens on a two way switch visit?

We test both switches and the cable between them, and we name the failed part before anything is changed.

  • Which switch failedWe ask which switch fails, whether the hall, the landing or both lost control, and when it began. We read the lighting breaker with you while the cover stays shut. No switch screw comes out until the tester shows the lighting circuit is dead.
  • Tests on both switches and the strappersWith the lighting circuit switched off, we measure at each switch and along the strappers. The readings separate a worn switch, a loose terminal and a broken strapper. A sound switch is left closed.
  • The failed part named before a priceWe name the failed switch, joint or cable before a part is fitted. Earthing, the path that carries fault current away, is checked on the visit. Bonding, the link between metal pipes and that earth, is checked before any further price, along with spare capacity on the supply.
  • Repair of that part and the certificateOnce you accept the repair we replace the failed switch, joint or cable and test the circuit again. A minor works certificate follows when that repair alters the circuit, under our NAPIT registration. The lighting breaker stays off when the circuit cannot safely be switched on again.

What does a two way switch fault cost?

Electrical Fault Finding & Repair is charged by the hour. The price covers tests at both switches and on the cable between them, the diagnosis we give you, and the start of the repair once you accept it. A second switch, a dimmer, a length of cable or a minor works certificate changes the price. Emergency electrician attendance is priced as its own job.

From £75 an hour

Included when agreed

  • Testing at the board and along the failed circuit until the cause is named
  • A spoken diagnosis before any part is swapped
  • Repair of the failed joint, accessory, cable or protective device once you accept the hourly work
  • Making the circuit safe if it cannot be left live that day
  • A minor works certificate when the repair needs one

Not included automatically

  • A full house rewire or a new consumer unit as the first step
  • Solar, battery, EV charger or forklift charger work
  • Guesswork replacement of parts that have not failed

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • Testing both switches and the strappers takes longer than confirming a spent lamp.
  • An MK Electric, BG Electrical or Varilight switch or dimmer is added only after the test shows it failed.
  • Fuse board replacement is written up separately when the lighting breaker or the board has failed.

View the fault finding cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about two way light switches

Still have a question?

Is a two way fault just a blown bulb?

Sometimes the lamp is all that failed, and both switches are sound. We prove the lighting circuit dead, then test the lamp, both switches and the strappers. A worn switch or an open strapper is named before a new switch is fitted.

Will you change both switches on the landing?

We change a switch only when its test shows it has failed. The other switch stays if it tests sound. Work on the failed switch, joint or cable starts on the visit once you accept it.

What paperwork follows a two way switch repair?

A minor works certificate is issued when the repair alters the lighting circuit, and it lists the test results with our NAPIT registration. If we only find the fault and change nothing, you still get the readings and the named part. An Electrical Installation Condition Report, an EICR, inspects the whole installation and is arranged separately.

Can a dimmer cause a two way switch problem?

Yes. A dimmer on one end of the pair can fail so the other switch cannot turn the light fully off. We test the dimmer and the plain switch separately. A Varilight, MK Electric or BG Electrical replacement is fitted only for the part that failed.

Do the sockets stay on during the test?

Sockets remain fed from their own breaker. We isolate the lighting circuit that serves this pair and leave other lighting circuits on. After the repair that circuit is made live again, or left off when it is unsafe.

Related problems

Sources

Updated 16 November 2026

Book or ask a question

Calls answered 24/7

Areas we cover (2)