Why does an extension lead get hot?
An extension lead gets hot because the current through the cable is more than the lead can lose as heat. A wound reel, several appliances on one lead, or a loose plug in a worn socket all raise that heat.
- Too much load on one leadA kettle, a heater or a tumble dryer draws a high current. Two of those on one extension lead warm the flex along its length. The heat is in the cable, not only at the wall.
- A cable reel still wound upA cable reel carries a lower current while the cable stays wound, because the turns trap heat. The rating is the highest current the lead is made to carry. The same appliance on a fully unwound lead runs cooler.
- One lead plugged into anotherA second extension lead between the wall and the appliance adds plugs and a longer run of thin cable. Each extra joint adds resistance, and resistance turns into heat at the pins. The wall socket then feeds more cable than the appliance needed.
- A worn wall socket at the plugLoose contacts in the wall socket spark against the plug pins. The spark heats the plug and the first part of the lead. Brown marks around the pin holes mean that socket is heating every plug used in it.
What can I check on a hot extension lead?
You can unplug the lead, look at the wall socket and count what was running. You leave every cover on, and you do not open the plug, the socket or the fuse board.
- Unplug the lead and let it coolSwitch the appliance off and pull the extension plug from the wall. The lead cools once the current stops. Leave it in the open while it cools, and leave it unplugged.
- See if the cable was still woundLook for a tight coil or a reel that is still wound. Heat in the middle of the coil means the lead ran while wound. A lead that is warm only on that coil was not fully unwound.
- Count what was plugged inNote each appliance that was on the lead. A heater, a kettle or a tumble dryer is a high load on its own. Two leads joined end to end count as one overloaded run.
- Look at the wall socket faceBrown stains, a faceplate that has gone soft, or pins that sit loose mean the wall socket is heating the plug. Stop using that socket. Leave the faceplate screws where they are.
When should I book for a hot extension lead?
Book Now when the lead was hot on one appliance, the wall socket is marked, or the appliance still needs power with the lead unplugged.
- The lead got hot on one applianceA heater, a dryer or a kettle warmed the cable by itself. That appliance needs a wall socket of its own. The lead stays out until a socket is fitted for it.
- The wall socket is brown or looseBrown marks or a plug that wobbles mean the socket contacts are loose. Each new plug heats those contacts again. Leave that socket empty.
- The appliance has nowhere else to goWith the hot lead unplugged, the appliance has no sound place to plug in. A new socket on a circuit that can carry the load takes the place of the lead. The position is the one on the quotation.
What happens on a visit for a hot extension lead?
We inspect the hot lead and the socket it fed from, test whether the circuit can take a fixed socket, and fit that socket only after you accept the work.
- The lead and the socket it usedWe ask which appliances were on the lead and whether the cable was still coiled. We look for brown marks on the plug and on the wall socket. We leave the hot lead unplugged.
- Earthing, bonding and spare capacityEarthing is the path that carries fault current so the breaker can open. Bonding joins metal pipes to the earth at the fuse board. We check both, and we check the supply can carry the appliance, before we price a new socket.
- The new socket or the burnt oneWe isolate that circuit, then we fit the quoted socket where the appliance stands or we replace the scorched socket. We take the faceplate off only the socket we are changing. A socket that tests sound stays closed.
- The test and the certificateWe switch the circuit back on and test the socket we worked on. A minor works certificate covers that change and shows our NAPIT registration. We leave the extension lead unplugged.
What does a socket for a hot extension lead cost?
Socket installation or replacement covers one quoted socket that takes the place of the hot extension lead. The price includes fitting that point and checking earthing, bonding and whether the circuit can carry the load. A second socket, wall chasing, making good, or a fuse board change is priced on its own line.
From £85
Included when agreed
- Fitting a new socket or replacing an existing socket at the quoted position
- Changing a light switch or damaged faceplate when that line is on the quotation
- Checking earthing, bonding and whether the circuit can carry the extra load
- The relevant electrical paperwork when the work is complete
- Removing packaging and leaving the room ready to use the new point
Not included automatically
- Plastering, painting or making good after any chasing
- A house rewire when the circuit cannot take another point
- A consumer unit replacement unless that is quoted as its own job
Ways to pay


- Pay by bank
- Bank transfer
- We replace a scorched wall socket only after the inspection shows the contacts have failed.
- Making good after any chasing sits on its own line, separate from the socket work.
- House rewiring is a separate price when the circuit cannot carry another socket.
How booking works
Tell us about the job
Tap Book Now and describe the work in the chat. Photos help.
Get your price
You see your price in the chat. A set price is paid at checkout; any other job is quoted first.
Choose your visit
Give your address and when you are free, and the visit is arranged.
Why choose Lighting Electrical
We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.
- Reviews
- 61
- Rating
- 4.7
- Trading since
- 2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”
Valandi Kotorri, Lighting Electrical
Book NowCan you fit a socket so I can stop using the extension lead?
Yes. We fit one socket beside the appliance when the circuit can carry that load. Before we price it we check earthing, bonding and whether the supply can take the extra current. The extension lead stays unplugged.
Will the whole house lose power while you fit the socket?
No. We switch off only the breaker for the socket we are fitting or replacing. Lights and sockets on the other breakers stay live. We switch that breaker back on after we test the finished point.
Do you repair the extension lead itself?
No. We do not repair the flex or the plug on the extension lead. We fit a fixed socket for the appliance, or we replace the wall socket when its contacts are burnt. The lead comes out of use.
What if the circuit cannot take another socket?
We leave the new socket off that circuit. We price house rewiring as a separate job because the existing circuit cannot feed another point. The hot lead stays unplugged.
Should I keep using the lead if only the plug gets warm?
No. Warmth at the plug is a poor contact, either in the plug or in the wall socket. Pull the lead out and do not use that socket. We inspect the socket and replace it when the contacts have failed.
Related problems
- Cracked plug socketA cracked plug socket stays unused until the face is replaced and the terminals behind it are tested.
- Loose or wobbly plug socketA loose plug socket has a moving faceplate or worn contacts, and we replace it after the circuit is tested.
- One side of a double socket not workingOne outlet on a double socket goes dead when its contacts or switch fail and the other outlet still has power.
- Sparks when turning on a socketA spark as the socket switch closes means a worn socket contact or a damaged plug.
- USB socket stopped chargingA failed charger inside the plate stops the USB ports while the plug outlets on that plate stay live.
- Yellowed or discoloured socket face plateEven yellowing across a cool face plate is aged plastic. Brown marks around the pin holes mean the socket is heating and should be replaced.
Sources
- Electrical Safety First: Safety Guidance
- HSE: Electrical Safety at Work
- BS 7671: IET Wiring Regulations (18th Edition)
Updated 16 November 2026