Previous DIY electrical work not certified

Uncertified DIY electrical work leaves the installation without an electrical safety report. Lighting Electrical in Peterborough inspects the fixed wiring and issues an EICR that records each circuit and the result.

Calls answered 24/7

  • 10 years trading

Why is previous DIY electrical work not certified?

It stays uncertified when no one tested the job and no certificate was issued. New circuits, a replacement fuse board and bathroom alterations are the jobs Building Regulations require to be notified.

  • A new circuit with no certificateA new circuit is a cable run with its own breaker, such as extra sockets or a new lighting run. In a home that work is notifiable. Without an electrical installation certificate there is no record of the tests.
  • A fuse board swapped with no paperworkReplacing the fuse board, also called the consumer unit, is notifiable. An RCD is the switch that cuts power when current leaks to earth. A DIY replacement can lack both an RCD and a test certificate.
  • A bathroom circuit added or alteredA room with a bath or shower is a special location. Adding or altering a circuit there is notifiable. A DIY shower supply or extractor with no certificate has missed that notification.
  • A lighting circuit extended too farExtending a lighting circuit adds joints and cable length. The cable can end up too small for the breaker that protects it. Loft joints added in that way were never tested for a continuous earth path.
  • An extra socket with no test recordA new socket on an existing circuit away from a bathroom often needs no Building Regulations notice. It should still have a minor works certificate. That certificate is the short record of the tests on the change.

What can I check safely with nothing opened?

You can read old paperwork and look at the closed fuse board and the outside of fittings. You leave every cover on and you do not touch a cable.

  • Certificates already in the houseLook for an electrical installation certificate, a minor works certificate or a Building Regulations compliance certificate for the DIY job. No paper for a new circuit or a replacement fuse board means that job was not certified.
  • Names on the closed fuse boardRead the circuit names through the closed cover. A handwritten addition or no RCD test button on the altered ways is a reason to book. Leave every screw in place.
  • Fittings that do not match the restNote loft lights, extra sockets, garden supplies and bathroom fittings that do not match the older work. A warm, browned or buzzing face means stop using that point. Leave the front screwed on.
  • Rooms the DIY work touchedList the rooms the earlier work touched. Try the lights in those rooms. Try a lamp you already trust in one socket on that work.

When should I book for uncertified DIY electrical work?

Book Now if there is no certificate for earlier electrical work and you are letting, selling or adding wiring, or if a fitting is hot, tripping or smelling of burning.

  • A let or a sale needs a reportPrivate rented homes in England need a current EICR. Buyers and lenders often ask for the same report before a sale. The inspection records the DIY alterations as they are.
  • A breaker will not hold or a fitting is hotLeave a breaker off when it opens again after one reset. A burning smell or a hot fitting means the same. Use the handle on the front, then Book Now.
  • More electrical work is plannedAn EV charger, shower, extra sockets or a new fuse board needs the present installation tested first. We check earthing and spare supply capacity before we price that work. Earthing is the path that lets fault current open a breaker.

What happens on a visit for uncertified DIY work?

We test the fixed wiring, including the DIY alterations, and write an EICR. Any repair is a separate choice after you hear the findings.

  • What was added and what paper existsWe ask what was added. We ask whether any certificate exists. We look at the fuse board, sockets, switches, fixed lights, outdoor points and bathroom fittings. No cover comes off until a tester shows the circuit is dead.
  • Tests with the power off, then onWe isolate the supply for part of the visit. Lights and sockets go off while that circuit is tested. Dead tests measure the earth path and the cable insulation. We then switch on and confirm each protective device disconnects.
  • How each observation is markedC1 means someone could be hurt now, so that circuit is switched off before we leave. C2 means the fault can cause harm and the report result is unsatisfactory. C3 is a recommended improvement and can sit on a satisfactory report. FI means we need to investigate further.
  • The report, then any repair you wantWe finish the EICR. We talk through what failed. The inspection price stops at the report. Further work such as fuse board replacement or house rewiring is quoted on its own. A minor works certificate is written only when we change a circuit, under our NAPIT registration.

What does inspecting uncertified DIY work cost?

The price covers inspection and testing of the fixed wiring, including the DIY additions, and the written EICR. More circuits, an outbuilding or a commercial board take longer and change the price. Repairs and a new fuse board are quoted after the report.

From £150

Included in the inspection

  • Visual check of the consumer unit, cabling, sockets, switches and fixed lighting
  • Dead and live tests on the circuits, including earth continuity and insulation resistance
  • Classification of each observation as C1, C2, C3 or FI on the report
  • A written EICR for the property, signed by us
  • A short talk through the findings before we leave

Not included automatically

  • Repair of faults found during the test
  • PAT testing of plug-in appliances
  • A new consumer unit or a rewire

Ways to pay

  • Visa
  • Mastercard
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Pay by bank
  • Bank transfer
  • Loft circuits, an outbuilding or a commercial board add time to the inspection.
  • A repair or a new fuse board is quoted after the report, not inside the inspection price.
  • A minor works certificate is charged only when we alter a circuit you have accepted.

View the EICR cost guide

How booking works

  1. Tell us about the job

    Tap Book Now and describe the work in the chat. Photos help.

  2. Get your price

    You see your price in the chat. A set price is paid at checkout; any other job is quoted first.

  3. Choose your visit

    Give your address and when you are free, and the visit is arranged.

Why choose Lighting Electrical

We work with Hager, Wylex, Contactum, BG Electrical, MK Electric, Varilight, myenergi, Ohme, Hypervolt, Andersen, Aico, FireAngel and Mira.

Photo of Valandi KotorriValandi KotorriElectrician
Reviews
61
Rating
4.7
Trading since
2016
“Ten years on Colchester housing stock and I have seen most of it: terraces where the lighting circuit has been extended once too often, boards fitted before RCDs were standard, new builds with sockets nowhere near the kitchen. I check the earthing, the bonding and whether the supply will carry another load before I price anything, because the age of a house settles nothing on its own.”

Valandi Kotorri, Lighting Electrical

Book Now

Questions about uncertified DIY electrical work

Still have a question?

Does a missing certificate mean the wiring is dangerous?

No. A missing certificate means the tests were not written down. The EICR marks danger as C1 or C2 and that circuit is switched off. Sound circuits remain on.

Will an EICR stand in for the certificate the DIY work never had?

No. The EICR describes the installation as it is today and gives a satisfactory or unsatisfactory result. It does not replace the certificate the original job should have had. If we later change a circuit, the minor works certificate covers that change only.

Can you correct the DIY faults on the same visit?

We name the failed part before we change anything. A small repair can go ahead once you accept the price. A new fuse board or a rewire is quoted as its own job and is not part of the inspection.

What do I need if a tenant added sockets in a rented home?

A private rented home in England needs a current EICR whatever was added. We test the fixed wiring as we find it, including those sockets. You get the written report, and any remedial price is separate.

Do you open walls to find every DIY joint?

No. We test from the fuse board and from fittings we can already reach. We do not open walls to trace a cable. FI on the report marks a point that still needs a closer look.

Related problems

Sources

Updated 16 November 2026

Book or ask a question